LPT62-M ARTESYN | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

60 Watts

Total Power: 60 - 80 Watts Input Voltage: 85 - 264 Vac 120 - 300 Vdc # of Outputs: Triple SPECIAL FEATURES ƒ Medical safety approvals ƒ Universal input ƒ 3” x 5” footprint ƒ Remote sense on main output ƒ Built-in EMI filter ƒ Low output ripple ƒ Adjustable 5V output ƒ Overvoltage protection ƒ Overload protection ƒ 110 KHz switching frequency ƒ LPX60 enclosure kit available ƒ RoHS compliant SAFETY ƒ VDE 0750/EN60601-1 (IEC601) 21310-3336-0015 ƒ UL UL2601 E182560 ƒ CSA CSA 22.2 No. 601.1 LR109492 ƒ CE Mark (LVD) Electrical Specifications Input Input range 85 - 264 Vac 120 - 300 Vdc Frequency 47 - 440 Hz Inrush current <18 A peak @ 115 Vac; <36 A peak @ 230 Vac, cold start @ 25 °C Input current 1.5A max. (RMS) @ 115VAC Efficiency 70% typical at full load EMI FCC Class A conducted; CISPR 22 Class A conducted EN55022 Class A conducted; VDE 0878 PT3 Class A conducted Safety ground leakage current <75 μA max. @ 50/60 Hz, 264 Vac input Output Maximum power 60 W for convection; 80 W with 30CFW forced air Cross regulation ±2% on output 1; ±5% on outputs 2, 3 Adjustment range -5, +10% minimum Hold-up time 20 ms @ 60 W load, 115 Vac nominal line Overload protection Short circuit protection on all outputs. Case overload protected @ 110% to 145% above peak rating Overvoltage protection 5.7 to 6.7 Vdc on the main output Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Data Sheet

Ordering Information

30CFM Forced Air Peak Load1 Regulation2 Ripple P/P (PARD)3 LPT62-M +5 V +12 V -12 V 0.7 A 0.3 A 0 A 7 A 3 A 0.7 A 8 A 3.5 A 1 A 10 A 6 A 1.5 A ±2% ±5% ±5% 50 mV 120 mV 120 mV LPT63-M +5 V +15 V -15 V 0.7 A 0.3 A 0 A 7 A 2.8 A 0.7 A 8 A 3.3 A 1 A 10 A 4 A 1.5 A ±2% ±5% ±5% 50 mV 150 mV 150 mV Environmental Specifications Operating temperature 0 °C to 50 °C ambient derate each output at 2.5% per degree from 50 °C to 70 °C, -20 °C startup Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating; non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 5G peak 5 Hz to

500 Hz, operational

Storage temperature -40 °C to 85 °C Temperature coefficient ±.04% per °C MTBF demonstrated >550,000 hours at full load and 25 °C ambient conditions Power Derating Curve Output Power (Watts) 0°C 20W 40W 60W 80W 10°C 20°C 30°C 40°C 50°C 60°C 70°C TA – Ambient Temperature – °C Natural Convection Cooling 40W 30W

30 CFM Forced Air Cooling

  1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10μF in parallel with a 0.1μF capacitor at rated line voltage and load ranges. 4. Minimum Loads are required. 5. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not intended for sale to End Users.

2900 S.Diablo Way Tempe, AZ 85282 USA +1 888 412 7832 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom +44 (0) 1384 842 211 Asia (HK) 14/F, Lu Plaza

2 Wing Yip Street

Kwun Tong, Kowloon Hong Kong +852 2176 3333 For more information: www.artesyn.com/power For support: productsupport.ep@artesyn.com Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. © 2016 Artesyn Embedded Technologies, Inc. All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal. www.artesyn.com LPT60-M Series-DS 22Mar2016 Mechanical Drawing 3.00" (76.2) 2.55" (64.8) 0.22" (5.6) 5.00" (127) 1.69" (42.9) 0.12" (3) SK 1 SK 2 0.15" (4) DIA (4 places) GND N M1 M2 Remote Sense ConnectorSK201 Voltage Adj. Pot 4.55" (115.6) L Pin Assignments Connector LPT62-M LPT63-M SK1-1 Line Line SK1-3 Neutral Neutral SK2-1 +12V +15V SK2-2 +5V +5V SK2-3 +5V +5V SK2-4 Common Common SK2-5 Common Common SK2-6 -12V -15V SK201-1 +Sense +Sense SK201-2 -Sense -Sense Mating Connectors AC Input Molex 09-50-8031 (USA) 09-93-0300 (UK) PINS: 08-58-0111 DC Outputs Molex 09-50-8061 (USA) 09-93-0600 (UK) PINS: 08-52-0113 Remote Sense Molex 22-01-2025 PINS: 08-52-0113 Astec Connector Kit #70-841-006, includes all of the above 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5mm) 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 VAC input, 25°C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.75lbs/0.34kg