130 Watts
Total Power: 80 - 130 Watts Input Voltage: 90 - 264 Vac # of Outputs: Triple SPECIAL FEATURES Medical and ITE safeties Active power factor correction 2” x 4” footprint Less than 1U high EN61000-3-2 compliant Remote sense Power fail Adjustable main output Built-in Class B EMI filter Overvoltage protection Overload protection Thermal overload protection LPX100 enclosure kit available RoHS compliant SAFETY TUV 60950, 60601-1 UL 60950, 60601-1 CSA 60950, 60601-1 NEMKO 60950, 60601-1 AUSTEL 60950, 60601-1 CB Certificate & report CE Mark (LVD) Electrical Specifications Input Input ra nge 90 - 264 Vac; 127 - 300 Vdc Frequency 47 - 63 Hz Inrush current 50 A max., cold start @ 25 °C Efficiency 82% typical at full load EMI/RFI FCC Class B conducted; CISPR22 Class B conducted; EN55022 Class B conducted; VDE0878PT3 Class B conducted Safety ground leakage current 275 µA @ 50/60 Hz, 264 Vac input Output Maximum power 80 W for convection;
130 W with 200 LFM forced air
All outputs adjustable: -20%, +10%, except for +24V output on LPT104-M which will be -10%, +20% and 3.3 V output on the LPT101- M +10%, -15% Hold-up time 10 ms @ 130 W load, 120 Vac input Overload protection Short circuit protection on all outputs. Case overload protected @ 110 - 160% above rating for V1 & V2, 150 - 250% for V3 Overvoltage protection 15 - 35% above nominal output Logical Control Power failure Active LowTTL logic signal goes high 100 - 500 msec after main output; it goes low at least 6 msec before loss of regulation Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Data Sheet
LPT100-M Series Data Sheet Environmental Specifications Operating temperature 0 °C to 50 °C ambient derate each output as 2.5% per degree from 50 °C to 70 °C. -20 °C start up Storage temperature -40 °C to +85 °C Electromagnetic susceptibility: Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating; non-condensing 10% to 90% RH, non-operating, non-condensing 10% - 95% Vibration IEC68-2-6 to the levels of IEC721-3-2 MTBF calculated 583,000 hours at full load and 25 °C ambient conditions. 230 Vac input, Bellcore Mechanical Drawing max lead protrusion min stand-off height 4 places mounting hole max screw head diameter 0.22"[5.6] PIN 1 (LIVE) PIN 3 (NEUTRAL) SK1 SK3 DETAIL A 4 (-) REMOTE SENSE SK2 GND ADJUST POT'S OUTPUT VOLTAGE SK3 SEE DETAIL A POWER FAIL COMMON (+) REMOTE SENSE 0.1 " [2,5] 1.29 " [32,7] 0.197 [5] 1.72 " [43,8] 3.72 " [94,6] [101,6] 0.16 [4] [50,8]
LPT100-M Series Data Sheet
Ordering Information
Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Maximum Load with 30CFM Forced Air Peak Load Regulation2 Ripple P/P (PARD)3 LPT101-M +3.3 V 0 A 13 A 18 A 20 A ±2% 50 mV +5 V 0 A 5 A 9 A 10 A ±5% 50 mV +12 V 0 A 1 A 2.3 A 2.3 A ±5% 120 mV LPT102-M +5 V 0 A 13 A 18 A 20 A ±2% 50 mV +12 V 0 A 5 A 9 A 10 A ±5% 120 mV -12 V 0 A 1 A 2 A 2 A ±5% 120 mV LPT103-M +5 V 0 A 13 A 18 A 20 A ±2% 50 mV +15 V 0 A 4 A 7.2 A 8 A ±5% 150 mV -15 V 0 A 1 A 1.5 A 2 A ±5% 150 mV LPT104-M +5 V 0 A 13 A 18 A 20 A ±2% 50 mV +24 V 0 A 1.5 A 3 A 3.5 A ±7% 240 mV +12 V 0 A 1 A 2.3 A 2.3 A ±5% 120 mV 1. Peak current lasting < 15 seconds with a maximum 10% duty cycle. 2 . At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3 . Peak-to-peak with 20 mHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. 4. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not intended for sale to End Users.
LPT100-M Series Data Sheet WORLDWIDE OFFICES Americas 2900 S.Diablo Way Tempe, AZ 85282 USA +1 888 412 7832 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom +44 (0) 1384 842 211 Asia (HK) 14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon Hong Kong +852 2176 3333 For more information: www.artesyn.com/power For support: productsupport.ep@artesyn.com Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. © 2016 Artesyn Embedded Technologies, Inc. All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal. www.artesyn.com LPT100-M DS 21Mar2016 Pin Assignments Connector LPT100-M SK1 PIN 1 Live PIN 3 Neutral SK2 PIN 1 V1out PIN 2 V1out PIN 3 GND PIN 4 GND PIN 5 GND PIN 6 GND PIN 7 V2out PIN 8 V3out SK3 PIN 1 Power Fail PIN 2 GND PIN 3 + Remote Sense PIN 4 - Remote Sense Mating Connectors AC Input (SK1) Molex 09-50-3031 PINS: 08-52-0072 AC Ground Molex 01-90020001 DC Output (SK2) JST VHR-8N PINS: SVH-21T-P1.1 Remote Sense (SK3) JST PHR-4; PINS: SPH-002T-PO.5S OR LANDWIN 2001S0400; PINS: 2005T Artesyn Embedded Technologies Connector Kit #70-841-026, includes all of the above Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±.02”. 3. All mounting holes should be grounded for EMI purpose 4. Mounting M1 is safety ground connection 5. Specifications are for convection rating at factory settings at 115 Vac input 25 °C unless otherwise stated. 6. This power supply requires mounting on metal standoffs 0.20” (5 m) in height. 7. For DC input an external DC safety rated fuse must be used. 8. Warranty: 2 year 9. Weight: 0.44 lb. / 0.20 kg