145 Watts

Total Power: 110 - 145 Watts Input Voltage: 85 - 264 Vac 120 - 300 Vdc # of Outputs: Quad SPECIAL FEATURES ƒ Active power factor correction ƒ IEC EN61000-3-2 compliance ƒ Adjustable outputs on 1, 3 & 4 Remote sense on main output ƒ Single wire current sharing ƒ Power fail and remote inhibit ƒ Built-in EMI filter ƒ Low output ripple ƒ Overvoltage protection ƒ Overload protection ƒ Thermal overload protection ƒ Adjustable floating 4th output ƒ RoHS compliant ƒ Optional cover (-C suffix) ƒ Optional fan cover (-CF suffix) SAFETY ƒ VDE 60950 ƒ UL 60950 ƒ CB Certificate and report ƒ CSA 60950 ƒ CE Mark (LVD) ƒ NEMKO EN 60950/EMKO-TUE Electrical Specifications Input Input ra nge 85 - 264 Vac; 120 - 300 Vdc Frequency 47 - 67 Hz Inrush current 38 A max, cold start @ 25 °C Efficiency 75% typical at full load EMI filter Meets FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted Power factor 0.99 typical Safety ground leakage current 1.0 mA @ 50/60 Hz, 264 Vac input Output Maximum power

80 W convection (60 W with cover -C)

145 W with 30 CFM forced air

(100 W with cover -C) Adjustment range 3.3 - 5.5V on main; -12 - 15V on 3rd output 3.3 - 25 V on 4th output Hold-up time 20 ms @175 W load at nominal line Overload protection Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating Overvoltage protection Tracks outputs 1, 3 & 4; 10 to 35% Data Sheet

AC power failure TTL logic signal goes high 100 - 500 msec after V1 output; It goes low at least 4 msec before loss of regulation Remote inhibit Requires contact closure to inhibit outputs Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection proteced. DC - OK TTL logic signal goes high after main output is in regulation. It goes low when there is a loss of regulation Environmental Specifications Operating temperature 0° to 50 °C ambient. Derate each output 2.5% per degree from 50° to 70 °C (except for -C version). Storage temperature -40 °C to +85 °C Temperature coefficient ±0.4% per °C Electromagnetic susceptibility Designed to meet IE61000-4, -2, -3, -4, -5, -6, -8, -11, Level 3 Humidity Operating; non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational MTBF demonstrated >550,000 hours at full load and 25°C ambient conditions

Ordering Information

Peak Load 1 Regulation 2 Ripple P/P (PARD)3 LPQ142 5 V (3.3 - 5.5 V) 0 A 12 A 25 A 27 A ±2% 50 mV

12 V 0 A 5 A 6 A 9 A ±3% 120 mV

-12V (-12 -15 V) 0 A 1 A 1.5 A 2 A ±3% <1% ±3.3-25 V 0.5 A 1.5 A 4.5 A 5 A ±3% <50mV or 1% 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. 4. Fourth (4th) output adjustable 3.3 - 25 V factory set at 5 V. 5. *Minimum loads are required when output set below 5 Volts 6. Remote inhibit resets OVP latch 7. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not intended for sale to End Users. Note: -C suffix added to the model number indicates cover option. -CF suffix added to the model number indicates fan cover option. Pin Assignments SK1 PIN 1 Ground PIN 3 Neutral PIN 5 Line SK2 PIN 1 +12 V PIN 2 Common PIN 3 -12 V PIN 4 Common PIN 5 +5 V to +25 V (float) PIN 6 Common (float) SK4 TB-1 Common TB-2 +5 V Pin Assignments SK6 PIN 1 N/C PIN 2 DC OK PIN 3 N/C PIN 4 V1 SWP PIN 5 Common PIN 6 +V1 sense PIN 7 Sense common PIN 8 + inhibit PIN 9 - inhibit PIN 10 Power fail Mating Connectors (SK1) AC Input Molex 09-50-8051 (USA Molex 09-91-0500 (UK) PINS: 08-58-0111 (SK2) Aux DC Output Molex 09-50-8061 (USA) Molex 09-91-0600 (UK) PINS: 08-58-0111 (SK6) Control Signals Molex 90142-0010 (USA) PINS: 90119-2110 or Amp: 87977-3 PINS: 87309-8 (SK4) Main Output Molex BB-19141-0058 Artesyn Embedded Technologies connector kit #70-841-017, includes all of the above.

2900 S.Diablo Way Tempe, AZ 85282 USA +1 888 412 7832 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom +44 (0) 1384 842 211 Asia (HK) 14/F, Lu Plaza

2 Wing Yip Street

Kwun Tong, Kowloon Hong Kong +852 2176 3333 For more information: www.artesyn.com/power For support: productsupport.ep@artesyn.com Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. © 2016 Artesyn Embedded Technologies, Inc. All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal. www.artesyn.com LPQ142 Series-DS 18Mar2016 Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±0.02”. 3. Specifications are for convection rating at factory settings unless otherwise stated. 4. Mounting screw maximum insertion depth is 0.12”. 5. Warranty: 2 year 6. Weight: 1.63 lb/0.74 kg (4X) 63.5 1.5 (38.1) (3X) 19.1 29.1 161.5 171.5 7.0 (177.8) (2X) 6.4 (2X) 119.6 (2X) 139.7 SK1 N L GND SK6 SK2 MAIN OUTPUT 4.00 (101.6) #6-32 #6-32 #6-32 (8 places)M3 (8 places) 6 10 1 5 1 6 +12V OUT COMM -12V OUT COMM V4+ V4- V4 Adj - Course V1 Adj V4 Adj - Fine -CF option V3 Output Adjust Pot Mechanical Drawing