© 2023 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com Series KD/LD 5A/10A, 60Vdc Optically Isolated, Short-Circuit Protected DC Solid-State Relay Part Number* Description KD00CK 5A Solid State Relay KD02CK 5A SSR with Switch Status KD20CK 5A SSR with Short Circuit Protection KD22CK 5 A SSR with Short Circuit Protection and Switch Status LD00CM 10A Solid State Relay LD02CM 10A SSR with Switch Status LD20CM 10A SSR with Short Circuit Protection LD22CM 1 0A SSR with Short Circuit Protection and Switch Status

FEATURES

  • Available with short-circuit/current overload protection
  • Available with switch status output
  • TTL and CMOS compatible control
  • Low ON resistance power FET output
  • Fast switching speed
  • Meets 28 Vdc system requirements of MIL-STD-704
  • Optical isolation
  • Low profile hermetic package
  • Built and tested to the requirements of MIL-PRF-28750

DESCRIPTION

The Series KD and LD solid-state relays are screened utilizing MIL-PRF-28750 test methods and are packaged in low profile hermetically sealed cases. These relays are constructed with state-of-the-art solid state techniques and feature fully floating power FET output technology. This allows the load to be connected to either output terminal and provides a low ON resistance. The input (control) and output are optically isolated to protect input logic circuits from output transients. Available options include short circuit and current overload protection, which provides complete protection for both the relay and system wiring. This feature not only provides protection should a short or overload occur while the relay is on, but will also provide protection should the relay be switched into a short. The second option is a status output line. Switch status returns the true status of the output switch and is optically isolated from the load. It provides status indication independent of the control circuit of the relay. The status line provides a logic 0 (low) when the relay output is off with load voltage and continuity present, and a logic 1 (high) when the output is on. The KD and LD series are ideal for applications switching 36, 28, 14, and 12Vdc. *The Y suffix denotes parameters tested to MIL-PRF-28750 Specifications. The W suffix denotes parameters tested to Teledyne Specifications. ELECTRICAL SPECIFICATIONS (–55°C to +105°C UNLESS OTHERWISE NOTED) INPUT (CONTROL) SPECIFICATIONS When used in 2 terminal configuration (TTL or direct control) (See Fig. 1) Min Typ Max Units Input Current @ VBIAS = 5 VDC (See Fig 2) 15 mA Turn-Off Voltage (Guaranteed Off) 1.5 V DC Turn-On Voltage (Guaranteed On) 3.8 VDC Reverse Voltage Protection -32 V DC Input Supply Range (See Note 1, 7) 3.8 16 V DC INPUT (CONTROL) SPECIFICATIONS When used in 3 terminal configuration (CMOS or open collector TTL) Min Typ Max Units Control Current VCONTROL = 5 VDC VCONTROL = 18 VDC (See Note 7) 250 1.0 μADC mADC Control Voltage Range (See Note 7) 0 18 V DC Bias Supply Voltage (See Note 1, 7) 3.8 32 V DC Bias Supply Current @ VBIAS = 5 VDC 16 mA Control Turn-Off Voltage (Guaranteed Off) 3.2 VDC Control Turn-On Voltage (Guaranteed On) 0.3 V DC ENVIRONMENTAL SPECIFICATIONS Temperature Range Min Max Units Operating -55 +125 °C Storage -55 +125 °C Vibration, 100 g 10 3000 Hz Constant Acceleration 5000 g Shock, 0.5 ms pulse 1500 g Page 1

ELECTRICAL SPECIFICATIONS, CONT.

  1. Control input is compatible with CMOS or open collector TTL (with
  2. The rated input voltage is 5V for all tests unless otherwise specified.
  3. To calculate the maximum ON resistance for a give

Figure 4. Calculate the new ON resistance as follows:

5A/10A, 60Vdc Optically Isolated, DC Solid-State Relay Page 3 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2023 TELEDYNE RELAYS MECHANICAL SPECIFICATION Dimensions are shown in inches (mm) K PACKAGE NOTES, CONT.: 4. Overload testing to the requirements of MIL-PRF-28750 is constrained to the limits imposed by the short circuit protection characteristics as defined in this specification. System series inductance for “shorted-load” mode of operation should be 50 μH. M aximum repetition rate into a shorted load should not exceed 10 Hz. 5. A status pull up resistor is required for proper operation of the status output. Determine the current (Iso) required by the status interface. Calculate the current (Is) through the status resistor such that the sink current through the status output is 0.6 mA. Select the status resistor such that it does not allow more than 0.6 mA to flow through the status output. R STATUS = ( VSTATUS - 0.4V ) / Iso 6. Inductive loads should be diode suppressed. Input transitions should be ≤1 ms d uration and the input drive should be a bounceless contact type. 7. Parameter Guaranteed by design, but not tested 100% in product acceptance. Enclosure: Hermetically Sealed DIP Leak Rate: 1 x 10-6 cc/s Max Material: Header: Cold Rolled Steel Nickel Plated Pins: Copper Core Cover: Grade A Nickel Weight: 20 grams Tolerance: .XXX ± .005 L PACKAGE