EPC 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2003 TELEDYNE RELAYS EPC\\032003\\Q1 OUTPUT (LOAD) SPECIFICATION Min Max Unit Operating Range EPC24 115 265 Vrms EPC46 200 460 Vrms Peak Voltage (Clamping Voltage) EPC24 600 (450) Vpeak EPC46 1200 (800) Vpeak Internal Circuit Consumption EPC24 7 mArms EPC46 4 mArms Load Current Range (See Figure 8) EPC24N10A .01 10 Arms EPC24N40A .01 40 Arms EPC24N40R .01 40 Arms EPC46N70A .01 70 Arms EPC46N110A .01 110 Arms Series EPC INPUT (CONTROL) SPECIFICATION Min Max Units Control Voltage Range EPCXXNXXA 0 10 V EPC24N40R 1 5 V Control Current Range EPC24N40R 5.5 20 mAdc Must Turn-Off Voltage EPCXXNXXA 0.2 V Must Turn-Off Current EPC24N40R 4 mA Input Resistance (Typical) EPCXXNXXA 400 ±2% Ohms EPC24N40R 0.25 Ohms Min Max Unit Maximum Surge Current Rating (Non-Repetitive, See Figure 9) EPC24N10A 120 A EPC24N40A 550 A EPC24N40R 550 A EPC46N70A 1000 A EPC46N110A 2000 A On-State Voltage Drop All relays 1.6 V Off-State Leakage Current EPC24N10A 4 mArms EPC24N40A 4 mArms EPC24N40R 4 mArms EPC46N70A 5 mArms EPC46N110A 5 mArms Turn-On Time All relays (60 Hz) 8.3 ms Turn-Off Time All relays 41.5 ms Operating Frequency (Trimmer must be adjusted) All relays 47 100 Hz Off-State dv/dt (Non-Repetitive) All relays 500 V/ µs I2t for Match Fusing (<8.3ms) EPC24N10A 72 A 2S EPC24N40A 1500 A 2S EPC24N40R 1500 A 2S EPC46N70A 5000 A 2S EPC46N110A 20,000 A 2S OUTPUT (LOAD) SPECIFICATION (Continued)

© 2003 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com EPC 5 EPC\\032003\\Q1 Series EPC THERMAL CHARACTERISTICS Figure 8a – EPC24N10A Tcase max (˚C) 10 0 1 10 20 30 40 50 60 70 80 90 1001 10 1259876543210

240 Vac

440 Vac

87.590°C 2°C/W 4°C/W Without Heat Sink 5°C/W 0°C/W Ambient Temperature (°C)Load Current (Arms) Power Dissipation (W) 01 1 0 20 30 40 50 60 70 80 90 100 1 10 125 Tcase max (°C) 0 5 10 15 20 25 30 35 40 6590°C 0.4 °C/W 0.9°C/W 1°C/W 1.5°C/W 2°C/W 4°C/W Without Heat Sink 0°C/W 1.2°C/W 0.7°C/W Ambient Temperature (°C)Load Current (Arms) Power Dissipation (W) 10 20 30 50 60 0 10 20 30 40 50 60 70 80 90 100 90°C Max. case temperature (°C) 100 110 120 70 10040 80 90 110 1.2 °C/W 0.75 °C/W 0.2°C/W 2°C/W 0.1 °C/W 0.9 °C/W 0.55°/W 0°C/W Without Hea t Sink Ambient Temperature (°C)Load Current (Arms) Power Dissipation (W) 110A 70A Non-Repetitive Repetitive with initial Tj = 70˚C 100 150 Apeak 11 00.10.01 t (s) 200 400 600 Non-Repetitive Repetitive with initial Tj = 70°C Apeak 11 00.10.01 t (s) 500 1000 1500 Repetitive with initial Tj = 70°C Apeak 11 00.10.01 t (s) Non-repetitive 500 1000 1500 2000 Repetitive with initial Tj = 70°C Apeak 11 00.10.01 t (s) Non-Repetitive SURGE CURRENT Figure 8b – EPC24N40A, EPC24N40R Figure 8c – EPC46N70A, EPC46N110A Figure 9a – EPC24N10A Figure 9b – EPC24N40A, EPC24N40R Figure 9c – EPC46N70A Figure 9d – EPC46N110A NOTES: 1. Electrical specifications at 25°C unless otherwise specified. 2. Phase cutting generates RFI. Filters are recommended. 3. For inductive loads, contact factory.