DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
134 Page 1 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE ©2004 TELEDYNE RELAYS
www.teledynerelays.com 134/0704/Q1 ESTABLISHED RELIABILITY SERIES 134 CENTIGRID® ESTABLISHED RELIABILITY RELAYS SENSITIVE DPDT
DESCRIPTION
The 134 sensitiv e Centigrid ® relay retains the same features as the 114 standard Centigrid® relay with only a minimal increase in profile height (.375 in.). Its .100-inch grid spaced terminals, which preclude the need for spreader pads, and its low profile make the 134 relay ideal for applications where high packaging density is important. The following unique construction features and manufacturing techniques provide excellent resistance to environmental extremes and overall high reliability:
- All welded construction.
- Unique uni-frame design providing high magnetic efficiency and mechanical rigidity.
- High force/mass ratios for resistance to shock and vibration.
- Advanced cleaning techniques provide maximum assurance of internal cleanliness.
- Precious metal alloy contact material with gold plating assures excellent high current and dry circuit switching capabilities. The Series 134D and 134DD have internal discrete silicon diodes for coil suppression and polarity reversal protection. The sensitive 134 Centigrid ® relay has a high resistance coil, thus requiring extremely low operating power (200 mw typical). The advantages of reduced heat dissipation and power supply demands are a plus. By virtue of its inherently low intercontact capacitance and contact circuit losses, the 134 relay has proven to be an excellent ultraminiature RF switch for frequency ranges well into the UHF spectrum. A typical RF application for the Centigrid ® relay is in handheld radio transceivers, wherein the combined features of good RF performance, small size, low coil power dissipation and high reliability make it a preferred method of Transmit-Receive switching (see Figure 1). INTERNAL CONSTRUCTION SERIES DESIGNATION RELAY TYPE
134 DPDT basic relay
134D DPDT relay with internal diode for coil transient suppression 134DD DPDT relay with internal diodes for coil transient suppression and polarity reversal protection UPPER STATIONARY CONTACT LOWER STATIONARY CONTACT MOVING CONTACT UNI-FRAME ARMATURE ENVIRONMENTAL AND PHYSICAL SPECIFICATIONS Temperature (Ambient) –65°C to +125°C Vibration (General Note 1) 30 g’s to 3000 Hz Shock (General Note 1) 75 g’s, 6 msec, half-sine Acceleration 50 g’s Enclosure Hermetically sealed Weight 0.15 oz. (4.3g) max.
134 Page 3 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE ©2004 TELEDYNE RELAYS
www.teledynerelays.com 134/0704/Q1 ESTABLISHED RELIABILITY CASE DETAIL .375 (9.53) SQ. MAX. .335 (8.51) SQ. MAX. .375 (9.53) MAX. DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS) TERMINAL LOCATIONS (Viewed from Terminals; Numbers for Reference Only) –.001 (.03) WIRE LEAD .750 (19.05) MIN. (See Note 5) .031 ±.003 (.89 ±.25) .100 ±.010 (2.54 ±.25) TYP 8 PLACES 8 1 OUTLINE DIMENSIONS GENERAL NOTES 1. Relay contacts will exhibit no chatter in excess of 10 μsec or transfer in excess of 1 μsec. 2. “Typical” characteristics are based on available data and are best estimates. No on-going verification tests are performed. 3. Unless otherwise specified, parameters are initial values. 4. For reference only. Coil resistance not directly measurable at relay terminals due to internal series diode in 134DD only. 5. Unless otherwise specified, relays will be supplied with either gold-plated or solder- coated leads. 6. The slash and characters appearing after the slash are not marked on the relay. 7. Screened HI-REL versions available. Contact factory. SCHEMATIC DIAGRAMS Teledyne Part Numbering System for T2R® Established Reliability Relay ER 134 Z M4 - 26 A / S Q Established Reliability Designator Pad Option (See Appendix) Relay Series Ground Pin Option (See Appendix) Q= Solder-Coated Leads G= Gold-Plated Leads (Notes 5 and 6) S= .187" leads (Note 6) Coil Voltage Screening and Reliability Level Teledyne Part Numbering System for Military Qualified (JAN) Relays J 134 Z M4 - 26 P L Military (JAN) Designator Pad Option (See Appendix) Relay Series Ground Pin Option (See Appendix) Terminal Variant P = 0.187" Coil Voltage Screening and Reliability Level SCHEMATICS ARE VIEWED FROM TERMINALS 134 134D 134DD SERIES 134
bottom view dimensions Height For use with the following: Dim. H Max. “M4” Pad for TO-5 ER411T ER412, ER412D, ER412DD .295 (7.49) 712, 712D, 712TN, RF300, RF310, RF320 .300 (7.62) ER420, ER422D, ER420DD, 421, ER421D, ER421DD, ER422, ER422D, ER422DD, 722, 722D, RF341 .305 (7.75) ER431T, ER432T, ER432, ER432D, ER432DD .400 (10.16) 732, 732D, 732TN, RF303, RF313, RF323 .410 (10.41) RF312 .350 (8.89) “M4” Pad for TO-5 ER411, ER411D, ER411DD .295 (7.49) ER431, ER431D, ER431DD .400 (10.16) RF311 .300 (7.62) RF331 .410 (10.41) “M4” Pad for Centigrid® 172, 172D .305 (7.75) ER114, ER114D, ER114DD, J114, J114D, J114DD .300 (7.62) ER134, ER134D, ER134DD, J134, J134D, J134DD .400 (10.16) RF100 .315 (8.00) RF103 .420 (10.67) “M9” Pad for Centigrid® 122C, A152 .320 (8.13) ER116C, J116C .300 (7.62) ER136C, J136C .400 (10.16) RF180 .325 (8.25) A150 .305 (7.75) Notes: 1. Spacer pad material: Polyester /g191 lm. 2. To specify an “M4” or “M9” spacer pad, refer to the mounting variants portion of the part numbering example in the applicable datasheet. 3. Dimensions are in inches (mm). 4. Unless otherwise speci/g191 ed, tolerance is ± .010 (.25). 5. Add 10 m/g525 to the contact resistance show in the datasheet. Ø.150 [3.81] (REF) Dim H MAX Dim H MAX Dim H MAX .156 [3.96] (REF) .256 [6.5] (REF) Dim H MAX Appendix A: Spacer Pads © 2008 Teledyne Relays SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
bottom view dimensions Height For use with the following: Dim. H Max. “M” Pad 5/ 6/ ER411T, J411T, ER412, ER412D ER412DD, J412, J412D, J412DD ER412T, J412T .388 (9.86) 712, 712D, 712TN .393 (9.99) ER431T, J431T, ER432, ER432D ER432DD, J432, J432D, J432DD ER432T, J432T .493 (12.52) 732, 732D, 732TN .503 (12.78) ER420, J420, ER420D, J420D ER420DD, J420DD, ER421, J421 ER421D, J421D, ER421DD J422D, ER422DD, J422DD, 722 .398 (10.11) “M2” Pad 7/ 8/ ER411T ER412, ER412D, ER412DD J412, J412D, J412DD .441 (11.20) 712, 712D .451 (11.46) ER421, ER421D, ER421DD 722, 732D .451 (11.46) ER431T ER432, ER432D, ER432DD .546 (13.87) 732, 732D .556 (14.12) “M3” Pad 5/ 6/ 9/ ER411, ER411D, ER411DD ER411TX ER412X, ER412DX, ER412DDX ER412TX .388 (9.86) 712X, 712DX, 712TNX .393 (9.99) ER420X, ER420DX, ER420DDX ER421X, ER421DX, ER421DDX ER422X, ER422DX ER422DDX, 722X, 722DDX .398 (10.11) ER431, ER431D, ER431DD ER431TX ER432X, ER432DX, ER432DDX ER432TX .493 (12.52) 732X, 732DX, 732TNX .503 (12.78) Notes: 1. Spreader pad material: Diallyl Phthalate. 2. To specify an “M”, “M2” or “M3” spreader pad, refer to the mounting variants portion of the part number example in the applicable datasheet. 3. Dimensions are in inches (mm). 4. Unless otherwise speci/g191 ed, tolerance is ± .010” (0.25). 5/. Add 25 m/g525 to the contact resistance shown in the datasheet. 7/. Add 50 m/g525 to the contact resistance shown in the datasheet. 8/. Add 0.025 oz (0.71 g) to the weight of the relay assembly shown in the datasheet. 9/. M3 pad to be used only when the relay has a center pin (e.g. ER411M3-12A, 722XM3-26.) .370 [9.4] MAX SQ .150 [3.81] .100 [2.54] .200 [5.08] .300 [7.62] .100 [2.54] Dim H MAX .370 [9.4] MIN .014 [0.36] (REF) .390 [9.91] SQ .300 [7.62] .100 [2.54] .300 [7.62] .100 [2.54] .150 [3.81] .150 [3.81] .130 [3.3] Dim H MAX .370 [9.4] MAX SQ .150 [3.81] .100 [2.54] .200 [5.08] .300 [7.62] .100 [2.54] Dim H MAX .370 [9.4] MIN .014 [0.36] (REF) Appendix A: Spreader Pads (800) 284-7007 • www.teledynerelays.com /g391 +44 (0) 1236 453124 • www.teledyne-europe.com © 2008 Teledyne Relays
.100 [2.54] .100 [2.54] .100 [2.54] "Y" POSITION "Z" POSITION .100 [2.54] .100 [2.54] .100 [2.54] "W" POSITION "U" POSITION (ER116C and ER136C only) "X" POSITION "Z" POSITION "Y" POSITION .050 [1.27] 36°±3° Ø.200 [Ø5.08] "Z" POSITION "Y" POSITION "X" POSITION 45°±3° "Z" POSITION "Y" POSITION Ø.200 [Ø5.08] Centigrid® Relays: RF100, RF103, ER114, ER134, 172 Centigrid® Relays: RF180, ER116C, 122C, ER136C TO-5 Relays: ER411T, ER412, ER412T, ER420, ER421, ER422, ER431T, ER432, ER432T, 712, 712TN, 400H, 400K, 400V , RF300, RF303, RF341, RF312, RF310, RF313, RF320, RF323 TO-5 Relays: ER411, ER431, RF311, RF331 NOTES 1. Terminal views shown 2. Dimensions are in inches (mm) 3. Tolerances: ± .010 (±.25) unless otherwise speci/g191 ed 4. Ground pin positions are within .015 (0.38) dia. of true position Indicates ground pin position Indicates glass insulated lead position Indicates ground pin or lead position depending on relay type Appendix A: Ground Pin Positions © 2008 Teledyne Relays SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE