HVD3605A, HVD3220, HVD3206A, HVD310xA The HVD3000A series high voltage differential probes provide high CMRR over a broad frequency range to simplify the measurement challenges found in noisy, high common-mode power electronics environments. The probe’s design is easy-to-use and enables safe, precise high voltage floating measurements. Key Features
- 1 kV , 2 kV, 6 kV CAT safety rated models
- Widest differential voltage ranges available
- Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
- 1% gain accuracy
- High offset capability at both high and low attenuation
- AC and DC coupling
- ProBus activ e probe interface with automatic scaling
- AutoZ ero with auto disconnect switch
- Wide oscilloscope compatibility Exceptional Common-Mode Rejection Ratio The CMRR for the probes is exceptional out to very high frequencies, greatly improving measurement capability in the noisy, high common-mode environments found in power electronics. The high CMRR combined with low probe noise and high offset capability provides superior measurement capabilities compared to other HV differential probes. High Precision Measurements HVD3000A series probes provide 1% gain accuracy enabling precise voltage measurements. AutoZero capability ensures further measurement precision by allowing small offset drifts to be calibrated out of the measurement. This feature can be applied without removing the HVD3000A leads from the device under test. Widest Application Coverage The HVD3000A series cover the fullest range of applications, from 120/240 V switch-mode power supplies through
600 V class and 5 kV class electrical
apparatus, Each model has the best available gain accuracy, widest differential and offset voltage range, and superior CMRR.
1500 Vdc CAT III Rating
The HVD3220 and HVD3206A support
1500 Vdc solar photovoltaic (PV)
measurements per the IEC/EN 61010- 031:2015 standard. They have a
1500 Vdc CAT III and a 2000 V
(DC+peakAC) CAT I rating. Complete Probe Integration The ProBus interface provides power and communication to the probe eliminating the need for a separate power supply or batteries. Attenuation is automatically selected based on oscilloscope gain range (V/div) setting.
WIDE APPLICATION COVERAGE - 600 V TO 5 KV APPARATUS
600 V Class, 3-phase Electrical Apparatus
The HVD310xA probes are available in a range of bandwidths from 25 to 120 MHz with standard 2 meter cable (6 meter cable model available). All probes have industry best CMRR for best noise-immunity, are guaranteed to 1% gain accuracy, and have the industry’s widest differential voltage range in a 1 kV rated high voltage differential probe.
- Only 1 kV safety rated probe that serves the full 600 V class requirement
- 1500 V differential range with industry’s best overshoot measurement capability (to 2000 Vpk)
- Industr y’s best offset capability (1500 V) when used with HDO Series oscilloscopes
- Bandwidth rating up to 120 MHz
- 6 meter cable model available (HVD3106A-6M)
- Models a vailable without accessories for a lower cost (HVD310xA-NOACC) 5 kV Class, 3-phase Electrical Apparatus The HVD3605A probe is safety-rated for 6000 Vrms and 8485 V(DC + peak AC) for full coverage of 5 kV class apparatus. The probe has ample 100 MHz of bandwidth, is standard with a 6 meter cable, is guaranteed to 1% gain accuracy, has excellent CMRR, and has the industry’s widest differential voltage range.
- Only probe that permits AC Line, DC Bus, and Drive/Inverter output voltage probing through
4160 V apparatus ratings
- Industr y’s best overshoot measurement capability (to 7600 Vpk)
- Industr y’s best offset capability (6000 V) when used with HDO Series oscilloscopes
- Standard 6 meter cable *Based on 50% overshoot condition *Based on 25% overshoot condition Sinusoidal AC Line Input DC Bus Voltage Drive / Inverter Pulse-Width Modulated (PWM) Output Vrms or Vac Vpk-pk Vdc Vpk (Rated) V pk (with Overshoot)* Line-Line Line- Neutral Line-Line Line- Neutral Line-Line Line- Neutral 400 1131 653 566 566 327 849 491 480 1358 784 679 679 392 1019 588 600 1697 980 849 849 490 1274 735 690 1952 1127 976 976 563 1464 845 Sinusoidal AC Line Input DC Bus Voltage Drive / Inverter Pulse-Width Modulated (PWM) Output Vrms or Vac Vpk-pk Vdc Vpk (Rated) V pk (with Overshoot)* Line-Line Line- Neutral Line-Line Line- Neutral Line-Line Line- Neutral 2400 6788 3920 3395 3395 1960 4244 2450 3300 9334 5388 4666 4666 2694 5833 3368 4160 11766 6794 5884 5884 3397 7355 4246
WORLD’S ONL Y 2 KV SAFETY RATED MODEL Solar PV Inverters The HVD3220 and HVD3206A probes are rated to 1500 Vdc (2000 V DC + peak AC). This makes the probes ideal for testing single-phase or three-phase inverters or newer 1500 Vdc rated string-inverters (per IEC/EN 61010-031:2015). Both HVD3220 and HVD3206A have excellent gain accuracy (up to 0.35%), industry-leading CMRR, industry-best offset range, standard 2 meter cable, and a guaranteed 2000 Vpk differential voltage range.
- Only 1500 Vdc safety rated probe per IEC/EN 61010-031:2015
- Guaranteed 2000 Vpk differential voltage range
- Industr y’s best offset capability (1500 V) when used with HDO Series oscilloscopes
- Bandwidth rating up to 400 MHz
- 6 meter cable model a vailable (HVD3206A-6M) DC-DC Converters High-power DC-DC converters can operate at substantial voltages, 500 Vdc or higher. The HVD310xA models provide up to 1000 Vdc common-mode (HVD3206A models provide up to 1500 Vdc) and high precision (1% gain accuracy) DC voltage measurements. Automatic switchable attenuation keeps the probe in the optimum measurement range. Multiple probes can be used to understand complex device switching performance.
- Common mode range up to ±2000 V (DC + peak AC ) with HVD3206A
- High precision - 1% accuracy
- Automatic gain switching for optimum per formance *Based on 30% overshoot condition Solar String DC Bus Voltage Sinusoidal AC Output Vdc Vpk (Rated) V pk (with Overshoot)* Line-Line Line- Neutral Line-Line Line- Neutral 1000 849 490 1104 637 1500 849 490 1104 637 HVD3220 2 kV , 400 MHz
SUPERIOR PERFORMANCE AT LOWER VOLTAGES
120 V / 240 V Half-Bridge Circuit Topologies
Single-phase switch-mode power supplies and other devices utilizing half-bridge topologies need test and validation at DC bus voltages up to 340 Vdc with up to 680 Vp-p on the input voltage. HVD310xA probes are cost-effective solutions for probing the wide range of high voltage signals present in these systems. “No Accessory (NOACC)” versions of these probes permit additional cost savings. Use your existing accessories or purchase just the ones you want. MOSFET/IGBT Devices Upper-side Gate Drive Voltage Measurements Typically from 3 to 20 volts and “floating” at up to the DC Bus voltage. HVD-A Series probes can provide very good results, but the HVFO High Voltage Fiber Optic probe is optimized for the best upper-side gate drive voltage measurements with 140 dB CMRR, reduced DUT loading, and better pulse response. Lower voltage GaN power conversion measurement With 60 V of common mode, 80 V differential input range, and 1 GHz of bandwidth, DL-HCM probes provide the bandwidth and performance necessary for testing various low-power GaN systems.
- High precision - 1% accuracy
- Automatic gain switching for optimum per formance Input Voltage (Vrms or Vac) Input Voltage (Vpk-pk) DC Bus Voltage (Vdc) Output PWM Voltage (Vpk) 120 340 170 170 240 680 340 340
60 V Common Mode Differential Probes
- 48 V motors and drives
- High-power DC-DC converters
- GaN-based PDNs
- AC-DC switch-mode power supplies
- Wireless charging systems
- Gate-drive measurements
UNDERSTANDING HV DIFFERENTIAL PROBE RATINGS AC line voltages and power electronics systems can operate at very high voltages, and all parts of the measurement circuit are not necessarily connected to ground, requiring HV safety ratings. Additionally, a variety of terms may be used to describe the same voltage. Below is a simple tutorial to help you understand the various types of voltage terms and how they relate to each other. Understanding these voltage terms is necessary to ensure the correct probe selection. Rectified AC (DC Bus/Link Voltage) For three-phase inputs, the three Line-Neutral (L-N) AC Line inputs are rectified and summed to provide a “stiff” DC (bus/link) voltage for the input to an inverter subsection. The example shown to the right is for a 600 Vrms system. The Line-Neutral RMS voltages are 600V/√3, and each Vpeak(L-N) is calculated as √2*Vrms. The DC bus voltage after rectification and filtering is equal to √3*Vpeak(L-N), or 847 Vdc in this case. Single-phase AC Line Input Ratings are provided in Vrms (also referred to as Vac) referred Line-Neutral. AC Line inputs are usually grounded and these voltages can be assumed to have a 0V reference voltage. Vpeak is calculated as √2*Vrms and Vpk-pk is calculated as 2*Vpeak. The example to the right is for a 120 Vrms rating. Three-phase AC Line Input Ratings are provided in Vrms (also referred to as Vac) referred Line-Line (L-L), which can be converted in magnitude to a Line-Neutral basis by dividing by √3. Vpeak (L-L) is calculated √2*Vrms and Vpk-pk is calculated as 2*Vpeak. The example on the left is for a 480 Vrms three-phase rated system with signals shown as Line-Line. Inverter or Drive H-Bridge or Cascaded H-Bridge Outputs The nominal peak voltage (+ or -) of the PWM signals without accounting for signal overshoot is equal to the DC bus voltage. The measured 0V differential voltage value is not ground-referenced, and therefore a differential probe suitably rated to the DC bus voltage is recommended. Note that the +Vpeak and -Vpeak plus overshoot safety margin (typically ~50%) is what the HV differential probe must measure - Vpk-pk (2*Vpeak) will never occur in the circuit.
HVD3102A HVD3106A HVD3106A-6M Bandwidth 25 MHz 120 MHz 80 MHz Rise Time (10-90) 14 ns 2.9 ns 4.4 ns Differential Voltage Range (High Attenuation)
1500 V (DC + peak AC) from 7 to 500 V/
div with up to 1500 V offset.
1750 V maximum typical measurable
differential voltage before saturation. 1500 V (DC + peak AC) from 7 to 500 V/div with up to 1500 V offset.
2000 V maximum typical measurable differential voltage before saturation
Range (Low Attenuation) 27.6 V (DC + peak AC) from 100 mV/div to 6.9 V/div with up to 150 V offset Common Mode Voltage Range ±1500 V (DC + peak AC), 1000 Vrms Maximum Input Voltage to Earth ±1500 Vpk (nominal, either input to ground) Max Safe Input Voltage 1000 Vrms CAT III Sensitivity 100 mV/div to 6.9V/div (100X) 7V/div to 500V/div (1000X) 100 mV/div to 6.9V/div (50X) 7V/div to 500V/div (500X) 100 mV/div to 6.9V/div (50X) 7V/div to 500V/div (500X) Gain Accuracy 1% (LF, guaranteed) Slew Rate 100 V/ns (maximum) 400 V/ns (maximum) 270 V/ns (maximum) Attenuation 100x / 1000x 50x / 500x 50x / 500x Input Impedance 10 MΩ || 2.5 pF (between inputs), 5 MΩ || 5.0 pF (either input to ground) Input Coupling DC only Output Coupling AC or DC coupling Output Termination 1 MΩ Interface ProBus Input Lead Length 40 cm input lead length Cable Length (input lead to oscilloscope connection) 2.25 m 6.8 m Noise and Rejection CMRR (Typical) DC - 60 Hz: 85 dB
1 MHz: 65 dB
5 MHz: 40 dB
20 MHz: 30 dB
DC - 60 Hz: 85 dB
100 MHz: 30 dB
DC - 60 Hz: 85 dB
80 MHz: 30 dB
Noise (Probe) 100X: <15 mVrms 1000X: <85 mVrms (referred to input) 50X: <30 mVrms 500X: <150 mVrms (referred to input) 50X: <30 mVrms 500X: <150 mVrms (referred to input) Environmental Temperature (Operating) 0°C to 50°C Temperature (Non-Operating) -40°C to 70°C Humidity (Operating) 5% to 80% RH (Non-Condensing) up to 30°C, decreasing linearly to 45% RH at 50°C Humidity (Non-Operating) 5% to 95% RH (Non-Condensing), 75% RH above 30°C, 45% RH above 40°C Altitude (Operating) 3000 m maximum When used with clip accessories, 2000 m maximum Altitude (Non-Operating) 10,000 m Pollution Degree 2, Indoor use only Certifications CE (LVD Directive 2006/95/EC) IEC/EN 61010-031:2015 CE (EMC Directive 2004/108/EC) IEC/EN 61326-1:2013 UL Listed UL 61010-031 (Second Edition) cUL Listed CAN/CSA-C22.2 No. 61010-031-15
HVD3206A (HVD3206A-6M) HVD3220 HVD3605A Bandwidth 120 MHz (80 MHz) 400 MHz 100 MHz Rise Time (10-90) 2.9 ns (4.4 ns) 875 ps 4.3 ns Differential Voltage Range (High Attenuation)
2000 V (DC + peak AC) from 7 to 500
with up to 1500V offset.
2000 V (DC + peak AC) from
with up to 1500V offset.
1000 V (DC + peak AC) from
14 to 34.5 V/div with up to 750V offset.
7000 V (DC + peak AC) from
with up to 6000V offset. (7600 V maximum measurable differential voltage before saturation) Differential Voltage Range (Low Attenuation)
27.6 V (DC + peak AC) from
100 mV/div to 6.9 V/div with up to 150V offset.
400 V (DC + peak AC) from
7 V/div to 13.8 V/div with up to 300V offset.
200 V (DC + peak AC) from
500 mV/div to 6.9 V/div with up to 150V offset.
700 V (DC + peak AC) from
300mV/div to 27.5 V/div with up to 600V offset. Common Mode Voltage Range ±2000 V (DC + peak AC) ±2000 V (DC + peak AC) ±7600V (DC + peak AC), 6000 Vrms Maximum Input Voltage to Earth ±2000 Vpk (nominal, either input to ground) ±2000 Vpk (nominal, either input to ground) ±7600 Vpk (nominal, either input to ground) Max Safe Input Voltage 2000 V (DC + peak AC) CAT I *
1500 Vdc CAT III
1000 Vrms CAT III
2000 V (DC + peak AC) CAT I *
8485 V (DC + peak AC) CAT I *
6000 Vrms CAT I *
Sensitivity 100 mV/div to 6.9V/div (50X) 7V/div to 500V/div (500X) 500 mV/div to 6.9V/div (50X) 7 V/div to 13.8V/div (100X) 14 V/div to 34.5V/div (250X)
35 V/div to 500V/div (500X)
300 mV/div to 27.5 V/div (200X)
28 V/div to 2000 V/div (2000X)
Gain Accuracy 1% (LF, guaranteed) 0.35% - 0.7% (LF, guaranteed) 1% (LF, guaranteed) Slew Rate 400 V/ns (maximum) (270 V/ns) 1300 V/ns (typical) 1000 V/ns (typical) Attenuation 50x / 500x 50x / 100x / 250x / 500x 200x / 2000x Input Impedance 10 MΩ || 2.5 pF (between inputs) 5 MΩ || 5.0 pF (either input to ground)
10 MΩ || 2 pF (between inputs)
5 MΩ || 4 pF (either input to ground)
48 MΩ || 2.5 pF (between inputs) 24 MΩ || 5.0 pF (either input to ground) Input Coupling DC only Output Coupling AC or DC coupling DC only AC or DC coupling Output Termination 1 MΩ 50Ω 1 MΩ Interface ProBus Input Lead Length 40 cm 27 cm 40 cm Cable Length (input lead to oscilloscope connection) 2.25 m (6.8 m) 2.25 m 6.8 m Noise and Rejection CMRR (Typical) DC - 60 Hz: 85 dB DC - 60 Hz: 85 dB
5 MHz: 55 dB
20 MHz: 50 dB
100 MHz: 45 dB
300 MHz: 30 dB
DC - 60 Hz: 85 dB 10 kHz: 70 dB
1 MHz: 64 dB (200x)
1 MHz: 50 dB (2000x)
10 MHz: 40 dB (200x)
10 MHz: 30 dB (2000x)
Noise (Probe) 50X: <30 mVrms 500X: <150 mVrms (referred to input) 50X: 180 mVrms 100X: 180 mVrms 250X: 280 mVrms 500X: 300 mVrms (referred to input) 200x: <65 mVrms 2000x: <320 mVrms (typical, referred to input) Environmental Temperature (Operating) 0°C to 50°C Temperature (Non-Operating) -40°C to 70°C Humidity (Operating) 5% to 80% RH (Non-Condensing) up to 30°C, decreasing linearly to 45% RH at 50°C Humidity (Non-Operating) 5% to 95% RH (Non-Condensing), 75% RH above 30°C, 45% RH above 40°C Altitude (Operating) 3000 m maximum When used with clip accessories, 2000 m maximum Altitude (Non-Operating) 10,000 m Pollution Degree 2, Indoor use only Certifications CE (LVD Directive 2006/95/EC) IEC/EN 61010-031:2015 CE (EMC Directive 2004/108/EC) IEC/EN 61326-1:2013 UL Listed UL 61010-031 (Second Edition) – UL 61010-031 (Second Edition) cUL Listed CAN/CSA-C22.2 No. 61010-031-15 – CAN/CSA-C22.2 No. 61010-031-15 * CAT I per IEC/EN 61010-031/A1:2008. No Rated Measurement Category per IEC/EN 61010-031:2015. SPECIFICATIONS
Product Description Product Code 1 kV, 25 MHz High Voltage Differential Probe with 2 m cable HVD3102A 1 kV, 120 MHz High Voltage Differential Probe with 2 m cable HVD3106A 1 kV, 80 MHz High Voltage Differential Probe with 6 m cable HVD3106A-6M 1 kV, 25 MHz High Voltage Differential Probe with 2 m cable without tip Accessories HVD3102A-NOACC 1 kV, 120 MHz High Voltage Differential Probe with 2 m cable without tip Accessories HVD3106A-NOACC 2 kV, 120 MHz High Voltage Differential Probe with 2 m cable HVD3206A 2 kV, 80 MHz High Voltage Differential Probe with 6 m cable HVD3206A-6M 2 kV, 400 MHz High Voltage Differential Probe with 2 m cable HVD3220 6 kV, 100 MHz High Voltage Differential Probe with 6 m cable HVD3605A High Voltage Replacement Accessories Kit (Includes 2 each): High Bandwidth 4 mm Probe Tip Adapters, Safety Alligator Clips, Plunger Pincer Clips, Plunger Hook Clips, Plunger Alligator Clips, Spade Terminals PK-HV-001 © 2021 by Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice. Product or brand names are trademarks or requested trademarks of their respective holders. hvd3000a-probes-ds-14jan21 1-800-5-LeCroy teledynelecroy.com Local sales offices are located throughout the world. Visit our website to find the most convenient location. Customer Service Teledyne LeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties, our digital oscilloscopes are fully warranted for three years and our probes are warranted for one year. This warranty includes:
- No charge for return shipping • Long-term 7-year support • Upgrade to latest software at no charge