Features
- Open Loop transducer using the Hall effect
- Low voltage application
- Unipolar + 5 V DC power supply
- Primary current measuring range from 80 A up to 250 A
- Maximum RMS primary admissible current: defined by busbar to have T° < + 150°C
- Operating temperature range: - 40°C < T° < + 125°C
- Output voltage: full ratiometric (in sensitivity and offset)
- Compact design for PCB mounting. Advantages
- Excellent accuracy
- Very good linearity
- Very low thermal offset drift
- Very low thermal sensitivity drift
- Wide frequency bandwidth
- No insertion losses. Automotive applications
- Electrical Power Steering
- Starter Generators
- Converters ... +Vc -Vc IP Vout Primary current IP Isolated output voltage
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com18october2011/2 HC2F100-SN CLIPS Signal +5V ASIC Output amplifier Gnd Hall Gnd Out +/- Ip Remarks
- General tolerance ± 0.2 mm
- VOUT > when IP flows in the direction of the arrow. Power supply decoupling capacitor: C2 = 47 nF EMC protection capacitor C3 = 4.7 nF Optional: High frequency signal noise filter: R1 > 100 Ω C1 = defined according to the system frequency bandwidth VC Dimensions HC2F100-SN CLIPS family (in mm) Secondary connection Connection Bill of materials
- Plastic case PBT GF 30
- Magnetic core FeNi alloy
- Pins and primary bus bar Copper alloy tin plated (lead free)
- Mass 6 g Electronic schematic Terminals Designations 3S upply voltage + 5 V DC 1V out 2G round E1 to E4 Ground (*) HC2F-SN CLIPS
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com18october2011/2 HC2F100-SN CLIPS Absolute maximum ratings (not operating) Operating characteristics )A/V(inGwithVG VVI C C OUTP 2 ×× −= Parameter Symbol Unit Specification ConditionsMin Typical Max Electrical Data Primary current, measuring range IPM A -100 100 @ - 40°C < T° < 125°C Supply voltage 1) VC V 4.75 5.00 5.25 @ - 40°C < T° < 125°C Output voltage (Analog) VOUT V VOUT = (VC/5) x (2.5 +0.02 x IP ) @ - 40°C < T° < 125°C Sensitivity G V/A 0.0196 0.02 0.0204 @ TA = 25°C; VC = 5 V Offset voltage VO V 2.481 2.5 2.519 @ VC = 5 V; TA = 25°C; IP = 0 A Current consumption IC mA - 15 20 @ - 40°C < T° < 125°C; 4.75 V < VC < 5.25 V Load resistance RL ΚΩ 2 - - Output internal resistance ROUT Ω - - 10 Performance Data (1) Sensitivity error εG % -2.0 ± 0.7 2.0 @ TA = 25°C, VC = 5 V; Gth = 0.02 V/A Electrical offset IOE A -0.7 ± 0.25 0.7 @ VC = 5.00 V; TA = 25°C VOE mV -14 ± 5 14 Magnetic offset IOM A -0.25 ± 0.15 0.25 @ After excursion to ± IP; TA = 25°C VOM mV -5 ± 3 5 IOE TCIOEAV mA/°C -7 ± 4 7 @ - 40°C < T° < 125°C; VC = 5.00 VAverage temperature coefficient of VOE TCVOEAV mV/°C -0.14 ± 0.08 0.14 Average temperature coefficient of G TCGAV %/°C -0.04 ± 0.02 0.04 @ - 40°C < T° < 125°C; VC = 5.00 V Linearity error εL % IP -1.0 ± 0.2 1.0 @ IP; VC = 5.00 V, TA = 25°C Response time tr µs - 15 20 @ di/dt = 50 A/µs; IT = 60 A Frequency bandwidth 2) BW kHz 20 - - @ -3 dB; IT = 20 A rms Output voltage noise peak-peak Vno p-p mV - 35 43 @ TA = 25°C; 0 Hz < f < 1 MHz Output voltage noise rms Vno rms mV - - 4 @ TA = 25°C; 0 Hz < f < 1 MHz Parameter Symbol Unit Specification Conditions Maximun peak primary current (not operating) IP max A Defined by busbar to have T° ≤ 150°C Primary nominal DC or current rms IPN A Defined by busbar to have T° ≤ 150°C Maximun supply voltage (not operating) VC max V 7 Secondary maximum admissible power PS max mW 150 Ambient operating temperature TA °C -40 < TA < 125°C Ambient storage temperature TS °C -40 < TS < 125°C Electrostatic discharge voltage VESD V 2000 Maximum admissible vibration γ m.s -2 100 see page 5/5 Rms voltage for AC insulation test 50 Hz, 1 min Vd V 1500 see page 5/5 Creepage distance dCp mm 1.67 Clearance dCI mm 1.80 CTI=425 Notes: 1) The output voltage VOUT is fully ratiometric. The offset and sensitivity are dependent on the supply voltage VC relative to the following formula: 2) Small signal only to avoid excessive heating of the busbar, the magnetic core and the ASIC.0 0.5 1.5 2.5 3.5 -100 -80- 60 -40- 20 02 04 06 08 01 00 Prima ry current Ip (A) Typical global accuracy (A) @25 -20°C < T° < 85°C
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com18october2011/2 HC2F100-SN CLIPS -1.0% -0.5% 0.0% 0.5% 1.0% 1.5% 2.0% 2.5% 3.0% 3.5% -40- 20 02 04 06 08 01 00 1201 40 T° (°C) Mean relative gain error (%) -40- 20 02 04 06 08 01 00 1201 40 Temperature T° (°C) Mean relative offset error (mV) -0.10% -0.08% -0.06% -0.04% -0.02% 0.00% 0.02% 0.04% 0.06% 0.08% 0.10% -100 -80- 60 -40- 20 02 04 06 08 01 00 Prim ary current Ip (A) Typical linearity (% of 100A) 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 -100 -80- 60 -40- 20 02 04 06 08 01 00 Primary current Ip (A) Output voltage (V ) Vout @25°C Vout @85°C Vout @125°C Fig. 3: Typical linearity versus primary current at T° = 25°C Fig. 4: Typical output voltage versus primary current across temperature Fig. 5: Typical sensitivity error versus temperature Fig. 6: Typical offset error versus temperature Influence of the external magnetic field Test conditions : - transducer sample : HC2F100-SN CLIPS - diameter of the disturbing conductor : 6 mm - dimension of the primary bus-bar : 6 x 2 x 200 mm - tested at ambient temperature Current levels: A LEM BCD E F GG1 G2 H HC2Fxxx-SN I disturbed+ LEM HC2Fxxx-SN L I J K I disturbed+ CASE 1C ASE 2C ASE 3C ASE 4 I disturbant+ 100 A- 100 A+ 100 A- 100 A I primary0 A0 A+ 100 A+ 100 A -0.5 0.5 AB CD EF G1 GG 2H IJ KL Position case1 case2 case3 case4
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com18october2011/2 HC2F100-SN CLIPS Sensitivity: The Transducer’s sensitivity G is the slope of the straight line Vout = f (IP), it must establish the relation: Vout (IP) = VC/5 (G x IP + 2.5) (*) (*) For all symetrics transducers. Offset with temperature: The error of the offset in the operating temperature is the variation of the offset in the temperature considered with the initial offset at 25°C. The offset variation I OT is a maximum variation the offset in the temperature range: IOT = IOE max - IOE min The Offset drift TCIOEAV is the IOT value divided by the temperature range. Sensitivity with temperature: The error of the sensitivity in the operating temperature is the relative variation of sensitivity with the temperature considered with the initial offset at 25°C. The sensitivity variation G T is the maximum variation (in ppm or %) of the sensitivity in the temperature range: GT = (Sensitivity max - Sensitivity min) / Sensitivity at 25°C. The sensitivity drift TCGAV is the G T value divided by the temperature range. Offset voltage @ IP = 0 A: Is the output voltage when the primary current is null. The ideal value of VO is V C/2 at V C = 5 V. So, the difference of VO -VC/2 is called the total offset voltage error. This offset error can be attributed to the electrical offset (due to the resolution of the ASIC quiescent voltage trimming), the magnetic offset, the thermal drift and the thermal hysteresis. Environmental test specifications Output noise voltage: The output voltage noise is the result of the noise floor of the Hall elements and the linear I C amplifier gain. Magnetic offset: The magnetic offset is the consequence of an over-current on the primary side. It’s defined after an excursion of I P max. Linearity: The maximum positive or negative discrepancy with a reference straight line VOUT = f (IP). Unit: linearity (%) expressed with full scale of IP max. Response time (delay time) tr: The time between the primary current signal and the output signal reach at 90 % of its final value Typical: Theorical value or usual accuracy recorded during the production. IP t [µs] I [A] IT 90 % IS tr PERFORMANCES PARAMETERS DEFINITIONS VOUT IP Non linearity example Reference straight line Max linearity error Linearity variation in I N % Name Standard Conditions Low T° storage IEC 60068 Part 2-1 T° - 40°C / 100 H not connected Thermal shocks IEC 60068 Part 2-14 T° - 30°C to 110°C /1000 cycles not connected Low T°operation at min supply voltage IEC 60068 Part 2-1 T° - 40°C / 1000 H supply voltage = 4.75 V Hight T° operation at max supply voltage IEC 60068 Part 2-2 T° 125°C / 1000 H supply voltage = 5.25 V Temperature humidity bias IEC 60068 Part 2-3 T° 90°C / 95 % RH/ 1000 H supply voltage = 5.25 V Pressure cooker T° 125°C / 100 % RH, P 0.178 Mpa/100 H supply voltage = 5 V Mechanical Tests Vibration IEC 60068-2-64 Room T°, acceleration 100 m/s2, frequency 20 to 500 Hz/96 H each axis Drop test IEC 60068 Part 2-29 Heigh 750 mm concret floor each directions EMC Test Electrostatic discharge JESD22-A114-B Applied voltage = ± 2 kV pin to pin number of discharge =1