Features
- Galvanic isolation between primary and secondary circuit
- Hall effect measuring principle
- Isolation voltage 3000V
- 2 isolated primary windings
- Low power consumption
- Extended measuring range(3 x IPN)
- Power supply from ±12V to ±15V
- Insulated plastic case recognized according to UL94-V0. Advantages
- Low insertion losses
- Easy to mount with automatic handling system
- Only one design for wide current ratings range
- Small size and space saving
- High immunity to external interference.
Applications
- Switched Mode Power Supplies (SMPS)
- AC variable speed drives
- Uninterruptible Power Supplies (UPS)
- Electrical appliances
- Battery supplied applications
- DC motor drives Application domain
- Industrial 061026/7 www.lem.comLEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Page 1/2
10.85 P=2.54 -V or 0 OUT 3.5 10.85 0.5 Terminal Pin Identification 19 Max. 20 Max. 15.4 Max. HX 05-NP 41123 Top view 3.5+/-0.5 Primary conductor diameter Secondary pins dimension 0.5 x 0.25 d Lot No. 4.5 HX 05-NP 10-NP d 0.8 1.0 HX 05-NP 10-NP 15-NP d 0.8 1.0 1.2 Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. Dimensions HX 05..15-NP (in mm. 1 mm = 0.0394 inch) 061026/7 www.lem.comLEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. Page 2/2