FLP-1250 MARKIMICROWAVE | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Features
Low Insertion Loss Excellent Return Loss High Stop Band Suppression 11th Order Filter FLP-1250.S2P Electrical Specifications – Specifications guaranteed from -55 to +100°C, measured in a 50Ω system. Parameter Frequency (GHz) Min Typ. Max 3 dB Cutoff Frequency 12.5 Passband Insertion Loss (dB) DC-11.5 0.6 Passband Return Loss (dB) DC-11.5 15 20 Stopband Suppression (dB) 19.5-32 40 50 15.5 25 30 Impedance () 50 RF Power (W) 1 Weight (g) 22 [10.4] .41 [27.94] .740 [18.80] .590 [14.99] 8 PL Ø.100 Thru .06 Rad 4 PL [2.54] [1.5] Model # [3.81] .150[1.90] .075 [6.98] .275 .250 [6.35] [20.32] .800 [5.1] 1.100 [MM] INCH PROJECTION XXX=±.005 XX=±.02 .370 [9.40] .38 [9.6] Typ .20
Fig. 1. Magnitude response for a typical FLP-1250. Model Number Description FLP-1250 12.5 GHz Lowpass Filter with SMA Female connectors1 1Default is SMA female connectors. Consult factory for other connector options. NOTE: Specifications are subject to change without notice. Contact Marki Microwave for the most recent specifications and data sheets. Marki Microwave reserves the right to make changes to the product(s) or information contained herein without notice. Marki Microwave makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does Marki Mi crowave assume any liability whatsoever arising out of the use of or application of any product. © Marki Microwave, Inc. -25 -20 -15 -10 -50 -40 -30 -20 -10 0 4 8 12 16 20 24 28 32 Frequency (GHz) Insertion Loss Return Loss Insertion Loss (dB) ReturnLoss (dB) Insertion Loss (dB) R