DFP1000 ARTESYN | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Voltage set point -48V ±0.1V @ 10A Total regulation Main output ±5.0% (Full load to no load) Auxiliary output, 5V, 0.5A max. ±5.0% Rise time At turn-on 1.0s, max. Transient response Main output 5.0% max. dev., 75% to 100% 1ms recovery step at 0.1A/µs Ripple and noise Main output 1.0V pk-pk, (20MHz) Overvoltage protection latching -57V to -60V min. Output power limit 1200W Short circuit protection Yes Current sharing ±10% sharing 0.1V/A droop 1/3L to FL INPUT SPECIFICATIONS Input voltage range 1000W 90 to 264VAC 1200W 108 to 264VAC Input frequency range 47Hz to 63Hz Input surge current 25°C cold start 36A typ. Input surge 300VAC 20ms Safety ground 254.4VAC, 50Hz 2.5mA leakage current Input current 90VAC, 1000W 14A rms max. Input fuse Replaceable 20A Power factor 110VAC 0.99 220VAC 0.98 DPF1000 SERIES Dual output [ 2 YEAR WARRANTY ]
- 1000W front end
- EN61000-3-2 compliant
- 11 x 6.0 x 5.0 inch size
- Hot pluggable
- N+1 redundancy
- Full set of status signals
- EN55022, EN55011 conducted emissions level A
- UL, VDE and CSA safety approvals The DPF1000 is a 1000W universal input AC/DC front end power supply in a fully enclosed hot pluggable case with built-in fan, handle, IEC input connector, on/off switch and DIN output signal connector. Providing dual 48V and 5V outputs with a full set of status signals. The DPF1000 is designed for use as a front end in medium power communication applications adopting distributed power architecture. The DPF1000 is fully compliant with EN61000-3-2. Standard features include current sharing and full protection against overvoltage, overload and short circuit. Remote or local system monitoring is possible via a full set of status signals that include fan fail, DC good, power fail, remote inhibit and current monitoring. The DPF1000, with full international safety approval and the CE mark, meets conducted emissions EN55022 level A. The DPF1000 can be used in conjunction with our complete range of 3 to 200W DC/DC converters to fully configure a distributed power system. SPECIFICATION All specifications are typical at nominal input, full load at 25 ° C unless otherwise stated PAGE 1 Notes 1 3 orthogonal axes, random vibration, 10 minute test per axis. EMC CHARACTERISTICS Radiated noise EN55022/11, FCC part 15 Level A Conducted noise EN55022/11 Level A FCC part 15 Level A Harmonic current emm. EN61000-3-2 Compliant transients/bursts Surge susceptibility EN61000-4-5 Level 3 GENERAL SPECIFICATIONS Hold-up time 110VAC, 60Hz 20ms @ 1000W Efficiency 110VAC @ 1kW 77% min. Isolation voltage Input/output 3000VAC Input/chassis 1500VAC Switching frequency 200kHz Approvals and VDE0805, EN60950, IEC950 standards UL1950, BABT CSA C22.2 No. 950 Weight 4.3kg (9.5Ibs) MTBF MIL-HDBK-217F 80,000 hours @ 25°C full load ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating ambient, FL 0°C to +50°C Non-operating -40°C to +70°C 50°C to 70°C Derate linearly ambient to 50% at +70°C Cooling Built-in fan Relative humidity Operating 5% to 85% RH Altitude Operating 10,000 feet max. Non-operating 30,000 feet max. Vibration (See Note 1) 5Hz to 500Hz 2.4G rms peak Shock MIL-STD-810E 516.4 Part IV
2 PFC Fail
3 5V Bias Return/Signal Return
4 Remote Inhibit H
5 Voltage Trim
13 Current Monitor +
14 Current Monitor -
15 Power Good L
16 Fan Fail Detect L
17 Power Fail Detect H
International Safety Standard Approvals VDE0805/EN60950/IEC950 File No. 10401-3336-1090 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR50913/LR101320 Certificate No. PS/606473 Control and supervisory functions Bias Supply H (Pin 1) Isolated 5V bias supply, maximum current 0.5A. Allows the system designer to power system control circuitry. PFC Fail L (Pin 2) A failure in the Power Factor Correction stage, i.e. loss of the 400V internal bus, is indicated by this open collector signal, asserted low. Bias Return L (Pin 3) Return path for the 5V bias supply. All signals are referenced to this return. Remote Inhibit H (Pin 4) The output is inhibited when this signal is tied high. IIL max. = 10mA. Voltage Trim (Pin 5) The output voltage can be adjusted up to -56V by connecting a 100k variable resistor between pin 5 and pin 14. Current Monitor (Pins 13, 14) Value: 0.1 x Iout. Tolerance: 10%. Range: 5 to 25A Power Good L (Pin 15) An open collector signal, asserted low. Threshold asserted: 44.5 to 46V, deasserted: 56.5 to 58V. See Figure 1. Fan Fail Detect L (Pin 16) An open collector signal, asserted low, indicates fan failure. See Figure 1. Power Fail Detect H (Pin 17) An open collector signal, asserted high, indicating AC line failure. The output voltage will stay within regulation 4ms after PFD is asserted. Protection features Overvoltage protection The unit will shutdown and latch off if the output voltage exceeds the OVP threshold. Input power recycling is necessary to restart the unit. Overcurrent and short circuit protection The unit is protected against an overload on its output in the range 25 to 30A, with automatic recovery on overload removal. Under short circuit conditions, the unit shuts down. Over temperature protection If the internal temperature of the unit exceeds a safe limit, the unit shuts down and will need power recycling to re-start. Input voltage sags A user supplied jumper inhibits operation of the unit in the 110V range. This limits the input current to a safe level when operating at 230V to prevent circuit breakers tripping under brown out. This programmable jumper can be accessible by removing the cover plate. Refer to view A on page 102. Load sharing The DPF1000-9617PE power supply provides load sharing capability for implementing parallel operation. An internal OR-ing diode is used in each output to provide N+1 redundancy. The power supplies will share the load current within ±10% from full load down to 1/3 of the rated current of each power supply. Method of current sharing of -48V output shall be via the "droop method", as illustrated in Figure 2 below: OUTPUT OUTPUT CURRENT RIPPLE TOTAL MODEL NUMBER VOLTAGE MIN MAX REGULATION -48V 0A 21A 1000mV ±5.0% DPF1000-9617PE +5V 0A 0.5A 100mV ±5.0% 50.4V (+5%) Output Current Output Voltage Total Output Tolerance Band 48V 46.9V 46.5V 45.6V (-5%) 10A 21A (1000W) 25A (1200W) +0.10V (48.1V) -0.10V (47.9V) Setting Tolerance Droop and Regulation CharacteristicsFigure 2:
1000 Watt
AC/DC PFC front-end for distributed power architectures DISTRIBUTED POWER FRONT END AC/DC POWER SUPPLIES | 1000W AC/DC PAGE 2http://www.artesyn.com Figure 1: AC Input 48V Output PFD Signal Power Good Signal t1 varies with line and load t2 > = 4ms t1 + t2 > =20ms t1 t2
ALL DIMENSIONS IN INCHES (mm) 11.00 (279.40) 0.25 (6.40) .98 (24.90) 3.00 (76.20) SEE DETAIL 'B' VIEW A VIEW B DETAIL 'A' DETAIL 'B' 6.52 (165.60) 6.00 (152.40) 5.00 (127.00) 2.149 (54.58) 1.606 (40.79) SEE DETAIL 'A' VIEW B VIEW A NL NL G (J2) DC connector Molex BMI receptacle 42474 part number 15-06-0240 or equivalent with Molex 5556 female crimp terminal part number 39-00-0182 or equivalent. (J1) AC connector Standard IEC connector. (J2) DC mating connector Molex BMI plug 42475 part number 15-06-0246 or equivalent with Molex 5558 male crimp terminal part number 39-00-0220 or equivalent. (J1) AC mating connector Standard IEC plug. PAGE 3 AC/DC PFC front-end for distributed power architectures 1000W AC/DC | DISTRIBUTED POWER FRONT END AC/DC POWER SUPPLIES
PAGE 4http://www.artesyn.com DS_DPF1000_19980401.PDF Data Sheet © Artesyn Technologies® 2000 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Ar tesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompa ny the sale of any such product(s) or information contained herein.