High efficiency topology, 87% typical at 5V Industry standard footprint Wide operating temperature, up to and exceeding +70˚C (natural convection) 90% to 110% output trim No minimum load Overvoltage protection Remote on/off Approvals to EN60950 and UL/cUL1950 Complies with ETS 300 019-1-3/2-3 Complies with ETS 300 132-2 (input voltage and current requirements) Complies with ETS 300 386-1 The CXE15 is a new high efficiency open frame isolated 15 Watt converter series in an industry standard footprint. The first four models in the series feature an input voltage range of 33 to 75VDC and are available in output voltages of 5V, 3.3V, 2.5V and 1.8V. The output voltage on each model is adjustable from 90% to 110% of the nominal value. Typical efficiencies for the models are 87% for the 5V, 86% for the 3.3V, 85% for the 2.5V and 83% for the 1.8V version. The CXE15 series also has a remote on/off capability, with active 'HI' or active 'LO' logic options available. Overcurrent and overvoltage protection features are included as standard. With full international safety approval including EN60950 and cUL1950, the CXE15 reduces compliance costs and time to market. CXE15 48V SERIES Single output CXE15 Single Series | 10.8 to 15W DC/DC High Efficiency DC/DC Converters [ 2 YEAR WARRANTY ] TÜV
SXA10 Series | 15W DC/DCCXE15 Single Series | 10.8 to 15W DC/DC High Efficiency DC/DC converters Characteristic Symbol Min Typ Max Units Notes and Conditions Input voltage - turn on V in (on) 30 33 36 V DC Input voltage - turn off V in (off) 27 30 33 V DC Hysteresis 3 V DC Turn on delay - enabled, T delay 1.5 4 msec With the enable signal asserted, then power applied (power) this is the time from when the input voltage reaches the minimum specified operating voltage until the output voltage is within the total regulation band Turn on delay - power T delay 2.5 4 msec V in = Vin (nom), then enabled. applied, then enabled (enable) This is the time taken until the output voltage is within the total error band Rise time T rise 0.6 1 msec From 10% to 90%; full resistive load, no external capacitance Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any other conditions in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect devi ce reliability. All specifications are typical at nominal input Vin = 48V, full load under any resistive load combination at 25 ˚C unless otherwise stated. Characteristic Symbol Min Typ Max Units Notes and Conditions Input voltage - continuous V in (cont) -0.3 75 V DC V in(+) - Vin(-) Input voltage - peak/surge Vsurge -0.3 80 V DC 2s max, non-repetitive Operating temperature T op -40 115 ºC Measured at thermal reference points, see Note 1 Storage temperature T storage -40 120 ºC Output power (1.8V) Pout (max) 10.8 W Output power (2.5V) P out (max) 15 W Output power (3.3V) P out (max) 15 W Output power (5V) P out (max) 15 W Characteristic Symbol Min Typ Max Units Notes and Conditions Input voltage - operating V in (oper) 33 48 75 V DC Input current - no load l in 28 35 mADC V in (min) - Vin (max), enabled Input current - Quiescent l in (off) 20 25 mADC Converter disabled Input voltage variation dv/dt 5 V/ms Complies with ETS300 132 Part 4.4 Inrush current (i2t) linrush 300 µA 2s Complies with ETS300 132 Part 4.7, with recommended LISN Inrush current ratio I t/Im 19.5 Complies with ETS300 132 Part 4.7, with recommended LISN Input ripple rejection 45 dB Frequency <1 kHz Input fuse 2 A Slowblow/antisurge HRC recommended, 200V rating Absolute Maximum Ratings Input Characteristics Turn On/Off
CXE15 Single Series | 10.8 to 15W DC/DC High Efficiency DC/DC converters 3 www.artesyn.com Characteristic Symbol Min Typ Max Units Notes and Conditions Input to output test voltage 1500 V DC Test duration 1s Input to output capacitance 1000 pF Input to output resistance 100 M Ω Measured with 500 V DC Input to output insulation system Operational Characteristic - Signal Name Symbol Min Typ Max Units Notes and Conditions At remote/control ON/OFF pin See Notes 2 and 3 Open collector or equivalent See Application Note 116 for compatible Remote On/Off details Control pin open circuit voltage V ih 12 13 V I ih = 0 µA; open circuit voltage High level input current I ih 10 µA Current flowing into control pin when pin is pulled high (max. at Vih = 75V) Acceptable high level I ih (leakage) -50 µA Acceptable leakage current from leakage current signal pin into the open collector driver (neg = from converter) Low level input voltage V iI 0 1.2 V Converter guaranteed off when control pin is less than Vil (max) Low level input current I iI -1.4 mA V il = 0.4 V Low level input current I il (max) -1.5 mA V iI = 0.0 V; Characteristic Symbol Min Typ Max Units Notes and Conditions Mean time between failure MTBF 600,000 Hours MIL-HDBK-217F , Vin = Vin (nom); Iout = Iout (max); ambient 25ºC; ground benign environment Mean time between failure MTBF 1,000,000 Hours per Bellcore TR-NWT-000332 Issue 3, ground benign, temp. = 40ºC, V in = Vin (nom), Iout = Iout (max) Mean time between failure MTBF TBD Hours Demonstrated. This entry will be periodically updated as the number of test hours increase Expected service life Years Signal Electrical Interface Reliability and Service Life Isolation
SXA10 Series | 15W DC/DCCXE15 Single Series | 10.8 to 15W DC/DC High Efficiency DC/DC converters Other Specifications Environmental Specifications EMC Electromagnetic Compatibility Referenced ETSI standards: ETS 300 019: Environmental conditions and environmental tests for telecommunications equipment ETS 300 019: Part 1-3 (1997) Classification of environmental conditions stationary use at weather protected locations ETS 300 019: Part 2-3 (1997) Specification of environmental tests stationary use at weather protected locations Characteristic Symbol Min Typ Max Units Notes and Conditions Switching frequency F sw 265 kHz Fixed frequency Weight 12 g Phenomenon Port Standard Test level Criteria Notes and conditions Immunity: ESD Enclosure EN61000-4-2 6kV contact As per ETS 300 386-1 table 5 8kV air EFT DC power EN61000-4-4 2kV As per ETS 300 386-1 table 5 4kV Signal EN61000-4-4 1kV As per ETS 300 386-1 table 5 2kV Radiated field Enclosure EN61000-4-3 10V/m As per ETS 300 386-1 table 5 Conducted DC power EN61000-4-6 10V As per ETS 300 386-1 table 5 Signal EN61000-4-6 10V Signal line assumed < 3m in length Input transients DC power ETS 300 132, ETR 283 Characteristic Symbol Min Typ Max Units Notes and Conditions Thermal performance 1V8 and 2V5 models -40 70 ºC See Notes 1, 4 and 3V5 and 5V models -40 65 ºC individual derating curves Type Parameter Reference Test Level Notes and Conditions Air temperature Low IEC 68-2-1 -40ºC All characteristics and parameters High IEC 68-2-2 +70ºC extracted from ETS 300 019 Tmax. = +70˚C for T3.4 Relative humidity Low - 10% High IEC 68-2-56 100% Condensation IEC 68-2-30 90 to 100% Vibration IEC Class 3M5 Freq. velocity IEC 68-2-6 5-9Hz 5mm/s Freq. acceleration IEC 68-2-6 9-200Hz 1g Shocks IEC Class 3M5 Acceleration IEC 68-2-29 10g
Model Input Output Overvoltage Output Current Typical Max. Load Number Voltage Voltage Protection (Max.) Efficiency Regulation CXE15-48S1V8 33-75 VDC 1.8V 2.3V 6.0A 83% 2.0% CXE15-48S2V5 33-75 VDC 2.5V 3.2V 6.0A 85% 1.5% CXE15-48S3V3 33-75 VDC 3.3V 4.0V 4.5A 86% 0.5% CXE15-48S05 33-75 VDC 5.0V 6.0V 3.0A 87% 0.5% CXE15 Single Series | 10.8 to 15W DC/DC High Efficiency DC/DC converters 5 www.artesyn.com EMC Electromagnetic Compatibility Material Ratings Model Numbers Standards Compliance List Standard Category EN60950 2000 UL/cUL 1950 3rd edition TÜV Rheinland EN60950:2000 Characteristic - Signal Name Notes and Conditions Flammability rating UL94V-0 Material type FR4 PCB Performance criteria: NP: Normal Performance: EUT shall withstand applied test and operate within relevant limits as specified without damage. RP: Reduced Performance: EUT shall withstand applied test. Reduced performance is permitted within specified limits, resumptio n to normal performance shall occur at the cessation of the test. LFS: Loss of Function (self recovery): EUT shall withstand applied test without damage, temporary loss of function permitted du ring test. Unit will self recover to normal performance after test. Referenced ETSI standards: ETS 300 386-1 table 5 (1997): Public telecommunication network equipment, EMC requirements ETS 300 132-2 (1996): Power supply interface at the input to telecommunication equipment: Part 2 operated by direct current (DC ) ETR 283 (1997): Transient voltages at interface A on telecommunication direct current (DC) power distributions Phenomenon Port Standard Test level Criteria Notes and conditions Emission: Conducted DC power EN55022 Level A With recommended external filter for compliance bandwidth 20 kHz to 30 MHz, as per ETS 300 386-1. See Application Note 116 for details EN55022 Level B With recommended external filter for compliance bandwidth 20 kHz to 30 MHz, as per ETS 300 386-1. See Application Note 116 for details Signal EN55022 Level B Bandwidth 150kHz to 30MHz, as per ETS 300 386-1 Radiated EN55022 Level B Bandwidth 30 MHz to 1 GHz, as per ETS 300 386-1 Safety Agency Approvals Characteristic UL/cUL 1950 File Number E135734 TÜV Rheinland Certificate No. R2074133
SXA10 Series | 15W DC/DCCXE15 Single Series | 10.8 to 15W DC/DC High Efficiency DC/DC converters Input Characteristics CXE15-48S1V8 Model Electrical Characteristics - O/P CXE15-48S1V8 Model Characteristic Symbol Min Typ Max Units Notes and Conditions Nominal set-point voltage Vo (nom) 1.76 1.80 1.84 V DC V in = Vin (nom); Iout = Iout (nom) Worst case condition over line, load, temperature and life Total regulation band V o 1.74 1.86 V DC For all line, static load and temperature until end of life. Line regulation 0.5 % I out = Iout (nom); Vin (min) to Vin (max) Load regulation 2.0 % V in = Vin (nom); Iout (min) to Iout (max) Output current continuous Iout 0.00 6.0 A DC Output current - short circuit I sc 10 12 A rms Continuous, unit auto recovers from short, Vo < 100mV Output voltage - noise V p-p 40 70 mV pk-pk Measurement bandwidth 20 MHz Vrms 14 20 mV rms See Application Note 116 for measurement set-up details Characteristic Symbol Min Typ Max Units Notes and Conditions Input current - operating I in 0.271 0.274 A DC V in = Vin (nom); Iout = Iout (max.); Vo = Vo (nom) Input current - maximum I in (max.) 0.399 0.404 A DC V in = Vin (min); Iout = Iout (max.); Vo = Vo (nom) (measured at converter) Reflected ripple current I in (ripple) 1.8 mA RMS I out = Iout (max.), measured 5 mA pk-pk with external filter. See Application Note 116 for details Input capacitance - internal C input 1.5 µF Internal to converter filter Input capacitance - external C bypass 0 µF Recommended customer bypass added capacitance
CXE15 Single Series | 10.8 to 15W DC/DC 7 www.artesyn.com High Efficiency DC/DC converters Protection and Control Features CXE15-48S1V8 Model Efficiency CXE15-48S1V8 Model Characteristic Symbol Min Typ Max Units Notes and Conditions Efficiency η 82 83 % I out = 100% Iout (max), Vin = Vin (nom) Efficiency η 78 80 % I out = 50% Iout (max), Vin = Vin (nom) Electrical Characteristics - O/P CXE15-48S1V8 Model Characteristic Symbol Min Typ Max Units Notes and Conditions Load transient response - V dynamic 150 mV Peak deviation for 50% to 75% peak deviation step load, di/dt = 100mA/µsec Load transient response - T recovery 400 µsec Settling time to within 1% of recovery output set point voltage for 50% to 75% step load External load capacitance C ext 0 10,000 µF Characteristic Symbol Min Typ Max Units Notes and Conditions Overvoltage clamp voltage V ov 2.2 3.0 V DC Non-latching. Refer to Application Note 116 for details Overcurrent limit inception I oc 7.5 8.4 A DC V o = 90% of Vo (nom) Output voltage trim range 110 % Trim up (% of V o nom) 90 % Trim down (% of V o nom) See Application Note 116 for details of trim equations and trim curves Open sense voltage V DC No sense option
SXA10 Series | 15W DC/DCCXE15 Single Series | 10.8 to 15W DC/DC High Efficiency DC/DC converters Input Characteristics CXE15-48S2V5 Model Electrical Characteristics - O/P CXE15-48S2V5 Model Characteristic Symbol Min Typ Max Units Notes and Conditions Nominal set-point voltage V o (nom.) 2.44 2.50 2.56 VDC V in = Vin (nom); Iout = Iout (nom) Worst case condition over line, load, temperature and life Total regulation band V o 2.42 2.58 VDC For all line, static load and temperature until end of life Line regulation 0.5 % I out = Iout (nom); Vin (min) to Vin (max) Load regulation 1.5 % V in = Vin (nom); Iout (min) to Iout (max) Output current continuous I out 0.00 6 ADC Output current - short circuit I sc 10 12 A RMS Continuous, unit auto recovers from short, Vo < 100mV Output voltage - noise V p-p 40 70 mV pk-pk Measurement bandwidth 20 MHz Vrms 14 20 mV rms See Application Note 116 for set-up details Characteristic Symbol Min Typ Max Units Notes and Conditions Input current - operating I in 0.367 0.372 ADC V in = Vin (nom); Iout = Iout (max.); Vo = Vo (nom) Input current - maximum I in (max.) 0.541 0.548 ADC V in = Vin (min); Iout = Iout (max.); Vo = Vo (nom) Reflected ripple current I in (ripple) 1.8 mA RMS I out = Iout (max.), measured 5 mA pk-pk with external filter. See Application Note 116 details Input capacitance - C input 1.5 µF Internal to converter internal filter Input capacitance - C bypass 0 µF Recommended customer External bypass added capacitance
CXE15 Single Series | 10.8 to 15W DC/DC 9 www.artesyn.com High Efficiency DC/DC converters CXE15-48S2V5 Model Electrical Characteristics - O/P CXE15-48S2V5 Model Efficiency CXE15-48S2V5 Model Characteristic Symbol Min Typ Max Units Notes and Conditions Efficiency η 84 85 % Iout = 100% Iout (max), Vin = Vin (nom) Efficiency η 81 83 % I out = 50% Iout (max), Vin = Vin (nom) Characteristic Symbol Min Typ Max Units Notes and Conditions Load transient response - V dynamic 150 mV Peak deviation for 50% to 75% peak deviation step load, di/dt = 100 mA/µsec Load transient response - T recovery 400 µsec Settling time to within 1% of recovery output set point voltage for 50% to 75% step load External load capacitance C ext 0 10,000 µF Protection and Control Features Characteristic Symbol Min Typ Max Units Notes and Conditions Overvoltage clamp voltage V ov 2.7 3.75 V DC Non-latching Refer to Application Note 116 Overcurrent limit inception I oc 7.5 8.4 A DC V o = 90% of Vo (nom) Allowable output voltage 110 % Trim up (% of V o nom). Note trim range that the maximum output power is still 15W. Derate the maximum output current accordingly 90 % Trim down (% of V o nom) See Application Note 116 for details of trim equations and trim curves Open sense voltage V DC No sense function
SXA10 Series | 15W DC/DCCXE15 Single Series | 10.8 to 15W DC/DC High Efficiency DC/DC converters Input Characteristics CXE15-48S3V3 Model Electrical Characteristics - O/P CXE15-48S3V3 Model Characteristic Symbol Min Typ Max Units Notes and Conditions Nominal set-point voltage Vo (nom) 3.24 3.30 3.38 V DC V in = Vin (nom); Iout = Iout (nom) Worst case condition over line, load, temperature and life Total regulation band V o 3.19 3.41 V DC For all line, static load and temperature until end of life Line regulation 0.10 % I out = Iout (nom); Vin (min) to Vin (max) Load regulation 0.50 % V in = Vin (nom); Iout (min) to Iout (max) Output current continuous I out 0.00 4.5 A DC Output current - short circuit I sc 8.0 10 A rms Continuous, unit auto recovers from short, Vo < 100mV Output voltage - noise V p-p 70 100 mV pk-pk Measurement bandwidth: Vrms 20 35 mV rms 20 MHz. See Application Note 116 for measurement set-up details Characteristic Symbol Min Typ Max Units Notes and Conditions Input current - operating I in 0.360 0.364 A DC V in = Vin (nom); Iout = Iout (max.); Vo = Vo (nom) Input current - maximum I in (max.) 0.529 0.536 A DC V in = Vin (min); Iout = Iout (max.); Vo = Von o m(measured at converter) Reflected ripple current I in (ripple) 1.8 mA RMS I out = Iout (max.), measured 5 mA pk-pk with external filter. See Application Note 116 details Input capacitance - C input 1.5 µF Internal to converter internal filter Input capacitance - C bypass 0 µF Recommended customer external bypass added capacitance
CXE15 Single Series | 10.8 to 15W DC/DC 11 www.artesyn.com High Efficiency DC/DC converters CXE15-48S3V3 Model Electrical Characteristics - O/P CXE15-48S3V3 Model Efficiency CXE15-48S3V3 Model Characteristic Symbol Min Typ Max Units Notes and Conditions Efficiency η 85 86 - % Iout = 100% Iout (max), Vin = Vin (nom) Efficiency η 83 85 - % I out = 50% Iout (max), Vin = Vin (nom) Characteristic Symbol Min Typ Max Units Notes and Conditions Load transient response - V dynamic 100 mV Peak deviation for 50% to 75% peak deviation step load, di/dt = 100 mA/µsec Load transient response - T recovery 400 µsec Settling time to within 1% of recovery output set point voltage for 50% to 75% step load External load capacitance C ext 0 10,000 µF Protection and Control Features Characteristic Symbol Min Typ Max Units Notes and Conditions Overvoltage clamp voltage V ov 3.6 5.0 V DC Non-latching Refer to Application Note 116 Overcurrent limit inception I oc 5.6 6.3 A DC V o = 90% of Vo (nom) Allowable output voltage 110 % Trim up (% of V o nom). Note trim range that the maximum output power is still 15W. Derate the maximum output current accordingly 90 % Trim down (% of V o nom) See Application Note 116 for details of trim equations and trim curves Open sense voltage V DC No sense function
SXA10 Series | 15W DC/DCCXE15 Single Series | 10.8 to 15W DC/DC High Efficiency DC/DC converters Input Characteristics CXE15-48S05 Model Electrical Characteristics - O/P CXE15-48S05 Model Characteristic Symbol Min Typ Max Units Notes and Conditions Nominal set-point voltage V o (nom.) 4.90 5.00 5.10 VDC V in = Vin (nom); Iout = Iout (nom) Worst case condition over line, load, temperature and life Total regulation band V o 4.83 5.17 VDC For all line, static load and temperature until end of life Line regulation 0.1 % I out = Iout (nom); Vin (min) to Vin (max) Load regulation 0.3 0.5 % V in = Vin (nom); Iout (min) to Iout (max) Output current continuous I out 0.00 3 ADC Output current - short circuit I sc 5.5 7.0 A RMS Continuous, unit auto recovers from short, Vo < 100mV Output voltage - noise V p-p 70 100 mV pk-pk Measurement bandwidth 20 MHz Vrms 20 35 mV rms See Application Note 116 for set-up details Characteristic Symbol Min Typ Max Units Notes and Conditions Input current - operating I in 0.359 0.364 ADC V in = Vin (nom); Iout = Iout (max.); Vo = Vo (nom) Input current - maximum I in (max.) 0.529 0.541 ADC V in = Vin (min); Iout = Iout (max.); Vo = Vo (nom) Reflected ripple current I in (ripple) 1.4 mA RMS I out = Iout (max.), measured - 5.0 mA pk-pk with external filter. See Application Note 116 details Input capacitance - C input 1.5 µF Internal to converter internal filter Input capacitance - C bypass 0 µF Recommended customer External bypass added capacitance
CXE15 Single Series | 10.8 to 15W DC/DC 13 www.artesyn.com Protection and Control Features CXE15-48S05 Model Efficiency CXE15-48S05 Model High Efficiency DC/DC converters Characteristic Symbol Min Typ Max Units Notes and Conditions Efficiency η 86 87 % I out = 100% Iout (max), Vin = Vin (nom) Efficiency η 82 84 % I out = 50% Iout (max), Vin = Vin (nom) Electrical Characteristics - O/P CXE15-48S05 Model Characteristic Symbol Min Typ Max Units Notes and Conditions Load transient response - V dynamic 100 mV Peak deviation for 50% to 75% peak deviation step load, di/dt = 100mA/µsec Load transient response - T recovery 400 µsec Settling time to within 1% of recovery output set point voltage for 50% to 75% step load External load capacitance C ext 0 10,000 µF Characteristic Symbol Min Typ Max Units Notes and Conditions Overvoltage clamp voltage V ov 5.5 7.2 V DC Non-latching Refer to Application Note 116 Overcurrent limit inception I oc 3.7 4.2 A DC V o = 90% of Vo (nom) Allowable output voltage 110 % Trim up (% of V o nom). Note trim range that the maximum output power is still 15W. Derate the maximum output current accordingly 90 % Trim down (% of V o nom) See Application Note 116 for details of trim equations and trim curves Open sense voltage V DC No sense function
SXA10 Series | 15W DC/DCCXE15 Single Series | 10.8 to 15W DC/DC High Efficiency DC/DC converters 1.000 (25.40)TOP VIEW SIDE VIEW BOTTOM VIEW 2.000 (50.80) 0.800 (20.32) 0.200 (5.08) 0.300 (7.62) 0.10 (2.54) 0.400 (10.16) 0.800 (20.32) 0.120 (3.05) 0.100 (2.54) 0.800 (20.32) Case Outline 0.400 (10.16) 0.200 (5.08) 0.200 (5.08) .060 (1.52) Standoff (4 places) Plated Through Hole Recommended Hole Pattern 0.400 (10.16) 0.600 (15.24) 0.040 (1.02) Dimensions in Inches [mm] Figure 45: Dimensions and Pinout Pin Connections Pin No. Function
1 Vin -
3 On/Off (Optional)
4 Vout +
5 Trim (Optional)
6 Vout -
Hot spot temperature is defined as the highest temperature measured at any one of the specified hotspot checkpoints. See Figure 46: Hotspot temperature check points. Note 2 The control pin is referenced to Vin-. Note 3 The CXE15 is supplied as standard with active high logic. Control input pulled low: Unit disabled. Control input left open: Unit enabled. Note 4 Thermal reference set up: Unit mounted on an edge card test board 215mm x 115mm. Test board mounted vertically. For test details and recommended set-up see Application Note 116. CAUTION: Hazardous internal voltages and high temperatures. Ensure that unit is accessible only to trained personnel. The user must provide the recommended fusing in order to comply with safety approvals. CXE15 Single Series | 10.8 to 15W DC/DC High Efficiency DC/DC converters 23 www.artesyn.com Figure 46: Hot Spot Location on all Models
LFDS_CXE15_20021001.PDF Long Form Data Sheet Artesyn Technologies® 2001 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. CXE15 Single Series | 10.8 to 15W DC/DC High Efficiency DC/DC converters NORTH AMERICA e-mail: sales.us@artesyn.com 800 769 7274 +508 628 5600 EUROPEAN LOCATIONS e-mail: sales.europe@artesyn.com IRELAND +353 24 93130 AUSTRIA +43 1 80150 FAR EAST LOCATIONS e-mail: sales.asia@artesyn.com HONG KONG +852 2699 2868 24 www.artesyn.com