DC/DC CONVERTERS 10W DC/DC Converters 1

2 YEAR WARRANTY

  • 4:1 input voltage range
  • Approved to EN60950, UL1950, CSA C22.2 No. 950
  • Operating ambient temperature of -40°C to +70°C in still air
  • High demonstrated reliability with conservative component deratings
  • Complies with ETS 300 019-1-3/2-3
  • Complies with ETS 300 132-2 input voltage and current requirements
  • Fully compliant with ETS 300 386-1
  • Pin compatible with NFC10 and BXA10 series
  • Basic insulation system (input to output) The CXA10 series comprising of five different models delivers single and dual output voltages covering 3.3V, 5V, 12V, ±5V, ±12 and ±15V. The series has a wide 4:1 input voltage range of 18 to 75VDC. The CXA10 has been designed as a competitive open-frame alternative for the communications market. The product is supplied in the industry standard footprint of 2.0 x 1.0 x 0.394 inches. Other product features include overvoltage protection, short circuit protection and remote on/off. All components are placed in a fully automated environment. Planar magnetics are used in the design to improve the reliability and reduce the profile of the DC/DC converter. The series has full international safety approval to EN60950 and UL1950 reducing system compliance costs, and it has a basic insulation system from input to output making it suitable for a wide variety of applications. All specifications are typical at nominal input, full load at 25°C unless otherwise stated EMC CHARACTERISTICS ETS 300 386-1 table 5 Conducted emissions EN55022 (See Note 6) Level A EN55022, external filter, Level B VDE0878, 48V models Radiated emissions See Application Note 100 ESD air EN61000-4-2, level 3 ESD contact EN61000-4-2, level 4 Surge (500V) EN61000-4-5, level 3, 4 Fast transients EN61000-4-4, level 3, 4 Radiated immunity EN61000-4-3, level 3 Conducted immunity EN61000-4-6, level 3 GENERAL SPECIFICATIONS Efficiency See table Isolation voltage Input/output test voltage 1500VDC Switching frequency Fixed 400kHz Approvals and standards EN60950, UL1950 (See Notes 7,8,9,10,11) CSA C22.2 No. 950 Material flammability UL94V-0 Weight 12g (0.42 oz) MTBF MIL-HDBK-217F 456,621 hours (Representative model Parts stress method 48S05 @ 48Vin) Ground Benign @ 25°C ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating ambient -40°C to +70°C, temperature See curves Non-operating -55°C to +105°C ETS 300 019-2-3 Classes T3.1 to T3.5 Air temperature Low: IEC 68-2-1 -40°C High: IEC 68-2-2 +70°C Change: IEC 68-2-14 -40°C to +70°C Relative humidity IEC 68-2-56 10% to 100% RH IEC 68-2-30 Condensation Vibration, Class 3M5 IEC68-2-6 2 to 9Hz, 3mm disp. 9 to 200Hz 1g MIL-STD-202F Method 204 cond. A Shock, Class 3M5 IEC-68-2-29 Method 213B cond. A MIL-STD-202F OUTPUT SPECIFICATIONS Voltage accuracy ±1.0% Line regulation Singles/dual positives ±0.1% (LL to HL) Dual negatives ±0.2% Load regulation Full load to ±0.15% (not incl. cross reg.) minimum load Min. load All outputs 10% Ripple and noise 3.3V and 5.0V 30mV pk-pk 20MHz bandwidth All others 60mV pk-pk All models 12mV rms Temperature coefficient ±0.01%/°C Overvoltage protection Clamp type (See table and Notes 3, 4) Short circuit protection Hiccup Continuous Short <20mΩ auto. recovery Transient response Min. load to FL ±1.0% Load cross regulation Min. load to FL (See Note 1) ±5.0% INPUT SPECIFICATIONS Input voltage range 48Vin nominal 18 to 75VDC Input fuse (See Note 10) 1.5A HRC Max. input rise 48V ETS300 132-2 5V/ms and fall time UVLO turn ON voltage (See Note 5) 94% UVLO turn OFF voltage (See Note 5) 86% Remote ON/OFF (See Note 7) Logic compatibility CMOS/TTL/Open Collector ON Open circuit OFF <1VDC SPECIFICATIONS File Name: CXA10.PDF Rev: 11 Jan 2002

Data Sheet © Artesyn Technologies® 2002 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. For the most current data and application support visit www.artesyn.com/powergroup/products.htm Notes 1 Negative output voltage deviation when positive load is changed. 2 Guaranteed minimum output voltage range. 3 TVS spec: See Application Note 100 on our web site. 4 On dual output models, OVP protection is on negative outputs only. 5 With respect to minimum input voltage. 6 With one external ITW Paktron 4.7µF film capacitor across the input.

7 For units with optional remote ON/OFF , please add the suffix ‘-S’ to the

model number, e.g. CXA10-48S05-S. Additional alphanumeric suffixes maybe added to indicate minor modifications not affecting the safety approvals. 8 Unit provides basic insulation up to the 75VDC maximum input voltage. 9 Maximum continuous output power not to exceed 10 Watts. 7.9 Watts for the 3V3 model. 10 User must provide 1.5A in line fuse in order to comply with safety approvals.

11 Maximum temperature on components Q100, CR101, CR102 not to

° C. See Application Note 100 for details. CXA10 Series Single and dual output DC/DC CONVERTERS 10W DC/DC Converters 2 Please consult our website for the following items: 4 Application Note 4 Longform Data Sheet www.artesyn.com File Name: CXA10.PDF Rev: 11 Jan 2002 INPUT OUTPUT OVERVOLTAGE OUTPUT TYPICAL MODEL VOLTAGE VOLTAGE PROTECTION (3,4) CURRENT (MAX.) (9) EFFICIENCY NUMBER (7) 18-75VDC 3.3V 3.9V 2.4A 78% CXA10-48S3V3 18-75VDC 5.0V 6.8V 2.0A 81% CXA10-48S05 18-75VDC 12V 16V 0.83A 83% CXA10-48S12 18-75VDC ±5V ±6.8V 1.0A 81% CXA10-48D05 18-75VDC ±12V ±16V 0.41A 83% CXA10-48D12 18-75VDC ±15V ±19V 0.33A 81% CXA10-48D15 DERATING CURVE (Output Power %) AMBIENT TEMPERATURE (°C) Figure 1: Natural Convection (0.1m/s) Typical derating - See Application Note 100 100% 75% 50% 25% 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C 80°C 90°C 100°C Output Power (%) 27.5% 0.400 (10.16) 0.200 (5.08) 0.300 (7.62) Ø0.040 –0.002 Dia. (Ø1.02 –0.05) 0.020 (0.50) 0.100 (2.54) 345 621 0.142 (3.60) – 0.012 (0.3) –0.020 (0.5) 2.000 (50.80) 0.800 (20.32) 0.600 (15.24) 1.000 (25.40) – 0.020 (0.5) 0.394(10.00) Max. HEIGHT ALL DIMENSIONS IN INCHES (mm) Tolerance on all dimensions of – 0.005 (0.127) Unless otherwise specified – 0.012 (0.3) 0.536 (13.60) 0.400 (10.16) 0.400 (10.16) OPEN- FRAME PIN CONNECTIONS PIN NUMBER SINGLE OUTPUT DUAL OUTPUT 1 + Input + Input 2 – Input - Input 6 * Remote ON/OFF Remote ON/OFF 3 + Output + Output

4 No Pin Common

  • Optional remote ON/OFF pin. Please add the suffix ‘-S’ to the model number, e.g. CXA10-48S05-S (See Note 7). CAUTION: Hazardous internal voltages and high temperatures. Ensure that unit is not user accessible.