Features

This product supports industrial Ethernet protocols of differing makers, and can connect to the network of PROFINET, EtherNet/IP, Modbus TCP , CC-Link IE Field Basic, and EtherCAT with the switches on the product. 8 channels of independent IO-Link port 8 channels of IO-Link port (Class A) allow parameters to be set independently, and IO-Link mode and SIO mode can be set per port. In addition, digital input during IO-Link communication is achievable since No.2 pin of IO-Link port can be used as a digital terminal. Easy settings through a web browser Network settings and status check can be easily done through a web browser on the network from your PC. Adaptable to a temperature range between -20 and +60°C The product is capable of operating in the temperature between - 20 and + 60°C. It can be installed in the various environments. IP67 dust-proof and water-proof features With its dust-proof and water-proof design to meet the IP67 rating, the product can be used in locations subject to water or dust particles. (*IP67 is the performance indication when the waterproof caps specified by the CONTEC are set to all connectors.) M12 power connector adopted As for a power connector, M12 power connector (L-coded) is adopted. It supplies a large amount of power with its compact size. This product also has a FG terminal (functional grounding) for a power connector. Output terminal for power supply The power input in the power input terminal is branched and it will be output from the power output terminal. Since it can be used as the power for other devices, you can connect them in the daisy-chain connection. Equipped with LED for an operation check The product has LED for an operation check, which helps you visually confirm the communication status of each interface. Installation on the wall with screws The product can be installed on the wall with screws. Specifications Function specifications < 1 / 2 > Item Specifications LAN Transmission standard 100BASE-TX Data rate 10/100Mbps The number of ports Connector M12(D-coded, Female, 4-pin) LED ACT(Orange), LINK(Green) IO-Link Transmission scheme IO-Link protocol (Ver.1.0/Ver.1.1) The number of ports Connector M12(A-coded, Female, 5-pin)*1 Communication speed COM1: 4.8kbp, COM2: 38.4kbps, COM3: 230.4kbps Port class Type A Rated voltage 24VDC (typ.) Max. load current 200mA/port *2 Isolation specification Non-isolated LED A(Orange),ST(Green/Red), B(Orange) IO-Link (in SIO(DI)mode) Input type Current source output (PNP output ) support Rated voltage 24VDC (typ.) Input current 5mA (typ.) ON/OFF voltage 15VDC min. / 5VDC max. *3 IO-Link (in SIO(DI) mode) Output type Push-pull output *3 Rated voltage 24VDC (typ.) Output current 200mA/port *2 Output registance 3Ω max. IO-Link (Digital inputs for pin 2) Input type Current source output (PNP output ) support Rated voltage 24VDC (typ.) Input current 2mA (typ.) ON/OFF voltage 15VDC min. / 5VDC max. *3 LED ST(Green/Red)、BF/NS/ERR(Green/Red)、 SF/MS/RUN(Green/Red)、 SYS(Green, Orange) Switch Mode setting switch, Address setting selection switch, Address setting switch×2, Protocol setting switch *1 Connector pin 5 is left unconnected. *2 The total current of the C/Q, L+ line in all ports should be less than 1.6A. *3 Data 0 corresponds to Low level and Data 1 corresponds to High level.

Ver.1.04 CPSL-08P1EN 2 Function specifications < 2 / 2 > Item Specifications Power input *4*5 Rate input voltage (current) US : 24VDC (1.8A), UA : 24VDC (0.1A) Max. input current US : 12A, UA : 12A Input voltage range US : 20.4 – 26.4VDC, UA : 20.4 – 26.4VDC Device current comsumption US : 0.2A(Max.), UA : 0.1A(Max.) Connector M12(L-coded, Male, 5(4+FE)pin) Power output *4 Output voltage *6 US : US input voltage (Max.), UA : UA input voltage (Max.) Max. output current *7 US : 12A, UA : 12A Connector M12(L-coded, female, 5(4+FE)pin) Physical dimensions (mm) 69.0(W)×225.0(D)×18.0(H) (No projection included) Weight 600g Protective function IP67 *8 Installation method Installation with screws *9 *4 Use power cable within 3meters. *5 UA power is unavailable with this product. It is not necessary to supply power to UA when you only use the device on its own. *6 The voltage input to the power input terminal is output as it is, but if the current from the output terminal is large, a voltage drop may occur due to the internal resistance. *7 The total current from the power output current, device consumption current, and output current to the IO-Link port should be supplied to the power supply input terminal. *8 Do not use this product immersed in water. *9 The commercial screws are required individually. Installation Environment Requirements Item CPS-MM-LC Operating ambient temperature -20 - +60°C Operating ambient humidity 10 - 90%RH (No condensation) Non-operating ambient temperature -20 - +60°C Non-operating ambient humidity 10 - 90%RH (No condensation) Corrosive gases None Line-noise resistance Line noise AC line/±2kV *10 Signal line/±1kV(IEC61000-4-4 Level 3, EN61000-4-4 Level 3) Static electricity resistance Touch/±4kV(IEC61000-4-2 Level 2, EN61000-4-2 Level 2) Air/±8kV(IEC61000-4-2 Level 3, EN61000-4-2 Level 3) Vibration resistance (The product alone) *9 Sweep resistance 10 - 57Hz *11 / semi-amplitude vibration 0.15mm, 57 - 150Hz/2.0G 40minutes each in X, Y, and Z directions (JIS C60068-2-6- compliant, IEC60068-2-6-compliant) Altitude 5000m or less Shock resistance (The product alone) *10 15G half-sine shock for 11ms in X, Y, and Z directions (JIS C 60068-2-27 –compliant, IEC 60068-2-27 -compliant) Grounding Class D grounding (previous class 3 grounding) Standard VCCI ClassA, FCC ClassA, CE Marking(EMC Directive Class A, RoHS Directive) *10 When you use the CPS-PWD-90AW24-01 (optional power product) *11 When you use an optional power product:10 - 55Hz (See the manual of optional power product for details) Physical Dimensions Circuit Block Diagram Component Name No. Name Function 1 LAN Port It is a connector for Ethernet communuication. 2 FE Terminal It is a terminal for functional groudning. (This hole is also used to secure the main body with a screw). 3 Status LED Status of the product is indicated with LEDs. 4 Mode Setting Switch It is a switch for boot mode setting. (Do not perform any operations other than those described in this manual.) 5 Maintenance Connector Do not use this.

6 Address Setting Selection

It is a switch to select a setting method for the IP address of the product. 7 Address Setting Switch It is a switch to set an address of the product. 8 Protocol Setting Switch It is a switch to select an Ethernet protocol. 9 IO-Link Connector It is an IO-Link communication connector. 10 Screw Mounting Hole It is a hole to fix and secure the main body with a screw. 11 Power Input Connector It is a connector to supply power. 12 Power Output Connector It is a connector to send power to the outside. LAN Port Pin number Signal number Description

1 TX+

Transmission data (+) Output

2 RX+ Reception data (+)

3 TX- Transmission data (-)

4 RX- Reception data (-)

  • LAN Cable Compatible Connector M12 (For Ethernet), D-coded, 4-pin, Male Category Category 5e or better, a shielded cable (Double shield cable recommended) Cable Length Within 100 meters

Ver.1.04 CPSL-08P1EN 3 Protocol Setting Switch Setting value Setting contents [Factory settings] PROFINET

1 EtherNet/IP

2 Modbus TCP

3 CC-Link IE Field Basic

4 EtherCAT

5 - F Do not set anything. Address Setting Selection Switch Setting value Setting contents [Factory settings] DHCP *1

1 BOOTP *2

When using the product with fixed Set with the address setting switch. *1 3 - F Do not set anything. *1 Do not set this when setting PROFINET protocol / EtherCAT protocol. *2 Do not set this except when setting EtherNet / IP protocol. Address Setting Switch*1 When using the product with fixed addresses.(192.168.1.1 - 192.168.1.254). Set an IP address when choosing [2] in "Address Setting Selection Switch". There are two switches for setting addresses and the addresses are set in hex. “H” and “L” represent high bits and low bits respectively. The setting range is 01 - FEh (1 - 254). Setting value Setting contents 00h [Factory settings] Start up with the IP address set in CONPROSYS WEB Setting. 01 - FEh It is a setting range for addresses. FFh Set to "FF" and turn on the power. This restores IP address to the default settings. The SYS of the LED turns green. Check the green is on, and set back to "00", then start up again. [H] [L] *1 Do not set this when setting PROFINET protocol / EtherCAT protocol. IO-Link Connector Pin number Signal name Description

1 L+ Power supply to the connected

device (+)

2 DI Digital input

3 L- Power supply to the connected

device (-)

4 C/Q IO-Link communication/Digital

5 N.C. This is left unconnected - IO-Link Cable Compatible Connector M12, A-coded, 3 to 5-pin (in accordance with your use) , Male Cable Use a cable that withstands the temperature of 75°C and higher. Cable Length Within 20 meters - An example of connecting with the IO-Link device - An example of connecting with a 3-line sensor - An example of connecting with a 2-line sensor - A connecting example of DO output Power Input Connector Pin number Signal name Description

1 US I/O power /system power

2 GND_UA Ground of the auxiliary power

3 GND_US Ground of I/O power/system power

4 UA Auxiliary power

(Unavailable with this product) FE FE It is a terminal for functional grounding. Connect this to earth ground. - Power Input Cable Compatible Connector M12, L-coded, 5(4+FE)-pin, Female Cable Use a cable that withstands the temperature of 75°C and higher. Cable Length Within 3 meters Power Output Connector Pin number Signal name Description

1 US I/O power/system power

It is a terminal for functional grouding. It is connected to the FG termial at the top of the device. - Power Output Cable Compatible Connector M12, L-codec, 5(4+FE)-pin, Male Cable Use a cable that withstands the temperature of 75°C and higher. Cable Length Within 3 meters Product Configuration List Product …1 Product Guide … 1 Warranty Certificate …1 Serial number Label …1 Waterproof cap …1 Optional Products DIN rail fitting power supply CPS-PWD-90AW24-01: Fitting power supply 90W (Input: 100 - 240VAC, Output: 24VDC 3.8 A) CPS-PWD-30AW24-01: Fitting power supply 30W (Input: 100 - 240VAC, Output: 24VDC 1.3 A) * When connecting to the optional power supply of the CONTEC, alterations need to be undertaken to connect the M12 connector cable to the terminal. * Visit the Contec website for the latest optional products.