Ver.1.02 CPSA-PCB100 1 CONPROSYS Alpha Series PLC-Backup CPSA-PCB100 * Specifications, color and design of the products are subject to change without notice. * CODESYS® is a registered trademark of 3S-Smart Software Solutions GmbH. This product is a controller which periodically obtains and saves the programs and the configured data as well as the parameters of PLC used in a control device so that they can be restored easily when the system fails. It supports the PLCs of the most major manufacturers and backs up the specified area required by user. Setting the backup area can be specified with ease through a browser. * The contents in this document are subject to change without notice. * Specifications, color and design of the products are subject to change without notice. * Visit the CONTEC website to check the latest details in the document. * The information in the data sheets is as of April 2019. Features - PLCs of the most major manufacturers supported PLCs including TOYOPUC-PC10G series by JTEKT, JW300 series, JW50H/70H/100H series, and JW30H series by SHARP, MELSEC-Q series and MELSEC-FX series by MITSUBISHI are supported. - Backup Backup areas including PLC's "parameter", "program", and "setting data" can be specified. Moreover, up to 3 most recent backup data can be stored, and backup scheduling and manual setting can be performed. *Refer to the Reference Manual on the CONTEC website for available backup items and device ranges. - Monitoring function Backup history and elapsed days of PLC battery can be monitored. In addition, battery change date or the prospective day can be managed as well. - Compact design Compact design, 44.7(W)×94.7(D)×124.8 (H), features flexibility in installation. - Adaptable to a temperature range between -20 and +60°C The product is capable of operating in the temperature between -20 and + 60°C. It can be installed in the various environments. - A powerful running platform without fan The product contains the ARM ® Cortex®-A8 processor (600MHz) and the DDR3 512MB system memory. - Installation easy with two pieces of terminal support and DIN rail You can install and remove a terminal connector without a screwdriver so that it can shorten the time of the replacement. As the product can be mounted on a DIN rail, removing and replacing are easy as well. - Equipped with LED for an operation check The product has LED for an operation check, which helps you visually confirm the communication status of each interface. - No electrolytic capacitor battery No electrolytic capacitor is used. The Contec is creating the product with a longer life. Specifications Functional Specifications Item Description CODESYS Compatible Function Version V3.5 SP7 Patch2 or any later version Language LD, SFC, FBD, ST, IL, CFC (IEC61131-3 compliant) Field Bus Modbus TCP Master / Slave Communication Protocol OPC-UA Ser ver Program Size ROM Size 1MB The Number of Maximum Steps 250K steps CPU Basic Performance Basic Command Operation Speed (LD) 1.6nsec Applied Command Operation Speed (ST) 5.8nsec Jitter Maximum 300 μsec approx. Scan Time 74 μsec (at 20000 steps) Hardware Specifications Item Description CPU ARM Cortex-A8 600MHz Memor y On Board 512MB DDR3 SDRAM ROM On-Board 32MB NOR Flash for OS LAN Tran smission standard 10BASE-T/100BASE-TX The number of channels 2 Connector RJ-45 Connector LED Speed (Y ellow), Link/Act (Green) USB (reser ved) Tran smission standard USB2.0 stan dard follow The number of channels 1ch Connector TYPE-A SD card slot Standard SD standard follow (occupied) Connector SD memor y card slot LED Read/Write (Green) RS-232C Baud Rate 300bps - 115.2kbps Data length 5, 6, 7, 8 bit 1, 1.5, 2 stopbit Parity check Even, Odd, Non-parity Isolation/Resistance Non-isolated The number of channels 1 Connector 9-pin D-SUB connector (Male) LED Tran smission (Green), Reception (Green) Digital input and Output (reser ved) Input type Opto-coupler Isolation Input (Compatible with current sink output) (negative logic) *1 Input isolation Opto-cou pler Isolation Input voltage resistance 1000V The number of input signal channels

Ver.1.02 CPSA-PCB100 2 Item Description Open-circuit impedance 10kΩ or more Short-circuit impedance 500Ω or less Response time (digital input) Within 200μsec Interrupt (digital input) 4 interrupt input signals are arranged into a single output of interrupt signal. An interrupt is generated at the falling edge (HIGH-to-LOW transition) or rising edge (LOW-to-HIGH transition). (setting can be done by software) Output type Semiconductor relay output Output isolation Semiconductor relay isolation Output voltage resistance 1000V The number of output signal channels 4 *usable as digital input or digital output Maximum output voltage/current 13.2V/100mA Response time Within 2msec ON resistance 8Ω or less (at 25 °C) OFF leakage current 4μA or less (at 25 °C) Surge protection element Interactive TVS Diode Stand off voltage: ±30V, Peak pulse power : 400W (1ms) LED DI0-DI3 (Green) Connector 2-piece 3.81mm pitch 6-pin Terminal (N.C, DIO3, DIO2, DIO1, DIO0, MCOM) Applicable wire AWG28 - 16 Stack Bus The maximum number of stack buses 16 *2 LED Power (Green)/Status 1(Green) / Status2(Red)/ Error (Red) Switch (reser ved) Power SW, Rotary SW, DIP SW RTC RTC built-in (batter y within) Power su pply Rated input voltage 24VDC Input voltage range 21.6 - 26.4VDC Power con sumption Controller alone: 24V 0.3A (Max.) With module(s): 24V 3.6A (Max.) Connector 2-piece 3.5mm pitch 3-pin terminal (V+, V-, FG) Applicable wire AWG20 - 16 Surge protection element V+ - V-, V- - FG Interactive TVS diode Stand off voltage: ±30V, Peak pulse power: 400W (1msec) Physical dimensions (mm) 44.7(W) x 94.7(D) x 124.8(H) (No projection included) Weight 300g Installation method Quick mounting on the 35mm DIN rail OS Linux kernel 3.2 *1 Data 0 corresponds to High level and Data 1 corresponds to Low level. *2 The total current consumption of the devices should be less than 3.3A *3 Use power cable within 3meters. Installation Environment Requirements Item Description Operating ambient temperature -20 - +60°C *4 Operating ambient humidity 10 - 90%RH (No con densation) Non-operating ambient temperature -20 - +60°C Non-operating ambient humidity 10 - 90%RH (No con densation) Floating dust particles Not to be excessive Corrosive gases None Line-noise resistance Line noise AC Line/±2kV *4 Signal Line /±1kV (IEC61000-4-4 Level 3, EN61000-4-4 Level 3) Static electricity resistance Touch /±4kV (IEC61000-4-2 Level 2, EN61000-4-2 Level 2) Air /±8kV (IEC61000-4-2 Level 3, EN61000-4-2 Level 3) Vibration resistance Sweep resistance 10 - 57Hz *5 /semi-amplitude vibration 0.15mm, 57 - 150Hz/2.0G 40minutes each in X, Y, and Z directions (JIS C60068-2-6-compliant, IEC60068-2-6-compliant) Shock resistance 15G half-sine shock for 11ms in X, Y, a nd Z d ir ectio ns (JIS C 60068-2-27 –compliant, IEC 60068-2-27 -compliant) Grounding Class D grounding (previous class 3 grounding), SG-FG/ non-conduction Standard VCCI Class A, FCC Class A, CE Marking (EMC Directive Class A, RoHS Directive) *4 If you use the USB with bus power, operate the product at between -20 and +55°C. *5 When you use an optional power product *6 When you use an optional power product: 10-55Hz (See the manual of optional power product for details) PLC Specifications Item Description Supported PLCs *7 The same series of up to five PLCs can be connected. PLC by SHARP JW300 series "Configured data" backup available JW50H/70H/100H series, JW30H series "Program" "Configu red data" backup available PLC by Mitsubishi Electric MELSEC-Q series "Parameter" "Program" "Configured data" backup available MELSEC-FX series "Configured data" backup available PLC by JTEKT PC10G series "Configured data" backup available Communication method Ethernet or RS-422 (one-on-one connection) Communication speed 4800/9600/19200 BPS *7 Refer to the Reference Manual on the CONTEC website for available backup items and device ranges.。 CAUTION You can set the modules as you desire to the configurable controller up to 16 modules. The total current consumption of the modules should be less than 3.3A. Packing List - Product…1 - End Cover (attached to the product)…1 - Product Guide…1 - Warranty Certificate…1 - Serial Number Label…1 - 3-pin Connector…1 - 6-pin Connector…1 - DIN rail…1 - CODESYS Runtime license…1 (attached on the side of the product) * This product is verified in conformity with our recommended power supply. In case you use other power supplies, thus, it may not be able to fulfil certification requirements. Please see the Contec website regarding power supply recommendation (https://www .contec.com/). * Use the supplied plastic DIN rail when connecting this product and a module on a desk top for system development or validation. If you use the supplied plastic DIN rail in the field, it cannot be covered by warranty. Therefore, when you set the product and module in the field, use the commercially available DIN rail. Physical Dimensions [mm] 94.75.1 44.7 124.8 (14) Open Lock (18)

Ver.1.02 CPSA-PCB100 3 List of Options DIN rail fitting power supply CPS-PWD-90AW24-01 Fitting power supply 90W (Input: 100 - 240VDC, Output: 24VDC 3.8 CPS-PWD-30AW24-01 Fitting power supply 30W (Input: 100 - 240VDC, Output: 24VDC 1.3 Configurable type module CPS-COM-2PD with RS-422A/485 (2 ports) * Visit Contec website regarding the information on the optional products. Component Name No. Name Function

1 Stack Bus Used for power supply and communication with the configurable type

module. 2 Maintenance Connector Do not use it. 3 Power Connect or Use the 3-pin connector, included in the package. 4 LED Indicator 1 This indicates status of the product. 5 Rotar y Switch For both H and L of ID, use with the setting [00]. 6 Digital I/O Connector Do not use it. 7 LAN Port This is a connector for LAN. 8 DIP Switch Do not use it. 9 Power Switch This is used for controlling of the power supply. 10 SD Card Slot This product is equipped with SD card containing application software. 11 LED Indicator 2 This indicates the status of the product. 12 USB Port Do not use it. 13 RS-232C Serial Port This is a RS-232C serial port s (male).