DC/DC CONVERTERS 72-132W Wide Input DC/DC Converters 1

2 YEAR WARRANTY

  • Board mounted full brick with industry standard footprint
  • Adjustable output voltage with output currents of 40A
  • No minimum load required
  • 2:1 input range for battery powered applications
  • Synchronizable and parallelable with load sharing
  • Overtemperature and short circuit protection
  • Current monitor and power good signal
  • Remote ON/OFF
  • ISO9001 certified manufacturing facilities BXF200 Series high power density DC/DC converters can provide up to 40A output current and have an industry-standard footprint, measuring just 2.40 x 4.60 x 0.52 inches. The converters are equally suitable for new designs or as replacement power sources in existing equipment. BXF200 Series converters are designed specifically for redundant and distributed power systems in the computer and telecommunications sectors, but their feature-rich specifications make them suitable for a very wide range of applications. Using Bellcore 332, the MTBF is over 1,000,000 hours. Aluminium baseplate technology and four threaded M3 inserts make heatsink attachment and thermal management easy. The BXF200 Series is approved by UL, CSA and VDE. All specifications are typical at nominal input, full load at 25°C unless otherwise stated EMC CHARACTERISTICS Conducted emissions Bellcore 332 Level A (See Note 8) FCC part 15 Level A EN55022, CISPR22 Level A GENERAL SPECIFICATIONS Efficiency See table Isolation voltage Input/case 1500VDC Input/output 1500VDC Output/case 1500VDC Switching frequency Fixed 550kHz typ. Approvals and VDE0805, EN60950, IEC950 standards (See Note 4) UL1950, CSA C22.2 No. 950 Case material Aluminium baseplate and plastic casing Material flammability UL94V-0 Weight 200g (7.06oz) MTBF Bellcore 332 >1,000,000 hours MIL-HDBK-217F >200,000 hours @ 40°C, 100% FL ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating case temp. -40°C to +100°C Non-operating -55°C to +125°C Altitude Operating 10,000 feet max. Non-operating 40,000 feet max. Vibration 5Hz to 500Hz 2.4G rms (approx.) OUTPUT SPECIFICATIONS Voltage adjustability Model specific Set point accuracy ±0.5% typ., ±1.6% max. Line regulation Low line to high line ±0.1% typ. Load regulation Full load to min. load ±0.15% typ. Minimum load 0A Overshoot 0V Undershoot At turn-on and turn-off 0V Ripple and noise 5Hz to 20MHz (See Note 1) 20mV rms Temperature coefficient ±0.01%/°C Transient response Recovery time (See Note 2) 500µs Peak deviation 2.0% Remote sense 0.5VDC transmission line drop compensation INPUT SPECIFICATIONS Input voltage range 48VDC nominal 36 to 75VDC Input current No load 65mA max. Remote OFF 15mA max. Input current (max.) (See Note 3) See table Input reflected ripple (See Note 5) 11mA pk-pk Active low remote ON/OFF (See Note 7) Logic compatibility ON 1.2VDC max. OFF Open circuit Undervoltage lockout 48Vin: power up 35V typ. 48Vin: power down 33V typ. Start-up time Power up 2.5ms typ. (See Note 6) Remote ON/OFF 1ms typ. SPECIFICATIONS File Name: BXF200.PDF Rev: 10 Jan 2001

For the most current data and application support visit www.artesyn.com/powergroup/products.htm Notes

1 Measured with 10µF tantalum capacitor and 1µF ceramic capacitor across

the output. 2 Iout = Inom; delta Iout = ±25% Iout (max), di/dt = 1A/µs. 3 Input fusing is required based on surge and maximum input current.

4 This product is only for inclusion by professional installers within other

equipment and must not be operated as a stand alone product.

5 Input reflected ripple current test set-up uses a Pi filter; 220µF , 12µH,

100µF . 6 Start-up into resistive load.

7 Active high remote on/off is available (standard product is active low),

designate with the suffix ‘H’ e.g. BXF200-48S2V5H. 8 Units should be characterised within systems. External components and filtering required. PROTECTION Short circuit protection Continuous, automatic recovery Overvoltage protection Latching Thermal protection 110°C baseplate, automatic recovery TELECOM SPECIFICATION Central office interface A ETS300-132-2 BXF200 Series Single output DC/DC CONVERTERS 72-132W Wide Input DC/DC Converters 2 Please consult our website for the following items: 4 Application Note www.artesyn.com File Name: BXF200.PDF Rev: 10 Jan 2001 OUTPUT INPUT OVP OUTPUT INPUT OUTPUT EFFICIENCY REGULATION MODELPOWER VOLTAGE VOLTAGE CURRENT CURRENT (TYP.) LINE LOAD NUMBER (7) (MAX.) (MAX.) (MAX.) PIN CONNECTIONS PIN NUMBER FEATURE

1 Power Good

2 Current Monitor

3 Parallel

4 Trim Adjust

International Safety Standard Approvals VDE0805/EN60950/IEC950 File No. 10401-3336-0148 UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C EXTERNAL OUTPUT TRIMMING Output can be externally trimmed by using the method shown. TRIM DOWN RT1 OR RT2 TRIM UP

1 All dimensions in INCHES (mm). 3 All pins are tin/lead plated brass. TOP VIEW WITH OVERALL DIMENSIONS 2.40 (61.0) 2.00 (50.8) THREADED INSERTS M3 x 0.5 THROUGH

4 PLACES

4.20 (106.7) 4.60 (116.8) SIDE VIEW 0.53 (13.5) 0.00 (0.0) 0.20 (5.1) MIN. 2.600 (66.04) BOTTOM VIEW PIN DETAILS

11 PLACES

0.100 (2.54)

5 PLACES

0.200 (5.08)

7 PLACES

3 PLACES

6 PLACES

0.50 (12.7) 1.50 (38.1) 0.000 (0.00) 0.100 (2.54) 4.20 (106.7) 4.40 (111.8) 0.20 (5.1) 0.70 (17.8) 0.500 (12.70) 0.000 (0.00) 0.300 (7.62) 0.500 (12.70) 0.700 (17.78) 0.900 (22.86) 1.20 (30.48) 1.50 (38.1) 1.70 (43.2) 4 Data Sheet © Artesyn Technologies® 2002 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. For the most current data and application support visit www.artesyn.com/powergroup/products.htm BXF200 Series Single output DC/DC CONVERTERS 72-132W Wide Input DC/DC Converters 3 Please consult our website for the following items: 4 Application Note www.artesyn.com File Name: BXF200.PDF Rev: 10 Jan 2001