APR-B10 LEM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Features
- VFD and SCR waveforms current measurement
- True RMS output
- Split core type
- 5V & 10V switch selectable voltage output.
- DIN mounting & Panel mounting
- Eliminates insertion loss
- Switch selectable ranges Advantages
- Large aperture for cable up to Ø18mm
- High isolation between primary and secondary circuits
- Easy to mount
Applications
- VFD Controlled Loads: VFD output indicates how the motor and attached load are operating.
- SCR Controlled Loads: Acurate measurement of phase angle fired or burst fired (time proportioned) SCRs. Current measurement gives faster response than temperature measurement.
- Switching Power Supplies and Electronic Ballasts: True RMS sensing is the most accurate way to measure power supply or ballast input power. LEM Components www.lem.com Preliminary
Dimensions AP(R)-B10 (unit : mm, 1mm = 0.0394 inch) Mechanical characteristics
- General tolerance ±1 mm
- Primary aperture ∅ 18.5 mm
- Panel mounting 2 holes ∅ 4.0 mm
- Distance between holes 40.0 mm For panel mounting, replace M4 screws by new one (not supplied) with appropriate length to panel´s thickness. Connections
- Wires up to 2 mm ∅ LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. 2(out) 1(+)3(-) Output Range Switch 0-5, 10V Selectable AP/APR Connector Front Output Switch GND OUTPUT +24VDC R L