ADNB050-12-1PM-C ARTESYN | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 21

Technical content

Rev.04.19.16_#1.1 ADNB 60W Series Page 1 Technical Reference Note ADNB 60W Series Up to 60 Watts Din Rail Total Power: Up to 60 Watts Input Voltage: 88 to 264 Vac 124 to 370 Vdc # of Outputs: Single Special Features

  • Universal AC input 88-264Vac
  • Installed on DIN rail TS35/7.5 or 15
  • Brown-out Protection
  • Protections:Short Circuit/Over load/Over voltage
  • All using 105degC long life electrolytic capacitors
  • High operation temperature up to OC
  • Withstand 2G vibration test
  • High efficiency, long life and high reliability
  • 3 Years Warranty Safety* UL /cUL 508 TUV EN60950-1 UL1310 class 2 LPS Pass Note* - Cover AC input only Product Descriptions The ADNB 60W series features a universal 88-264Vac input – enabling it to be used anywhere in the world – and is also capable of operating from a 124- 370Vdc Input. The ADNB 60W series offers a power rating up to 60W with convection cooling, and it provides precisely regulated output voltages of 12V, 15V, 24V and 48Vdc. The ADNB 60W series power supply is comprehensively protected against over voltage, over load and short-circuit conditions.

Artesyn Embedded Technologies Rev.04.19.16_#1.1 ADNB 60W Series Page 2 Model Numbers Options None Model Output Voltage Minimum Load Maximum Load Effici ency 1 ADNB050-12-1PM-C 12Vdc 0A 5.0A 86% ADNB040-15-1PM-C 15Vdc 0A 4.0A 87% ADNB025-24-1PM-C 24Vdc 0A 2.5A 87% ADNB012-48-1PM-C 48Vdc 0A 1.25A 88% Note 1 - Typical value at nominal input voltage(230Vac) and maximum load.

Table 1. Absolute Maximum Ratings: Note 1 - Derate each output at 2.5% per degree C from 50 OC to 70 OC. Stress in excess of those listed in the “Absolute Maximum Ratings” may cause permanent damage to the power supply. periods may adversely affect the power supply’s reliability.

Table 2. Input Specifications:

1 All V IN,AC 88 115/230 264 Vac

Table 3. Output Specifications: Note 1 - Constant current and Auto recovery after fault condition is removed.

Artesyn Embedded Technologies Rev.04.19.16_#1.1 ADNB 60W Series Page 10 Protective Function Specifications Over Voltage Protection (OVP) The power supply output voltage latches off during output overvoltage with the AC line recycled to reset the latch. ADNB050-12-1PM-C ADNB040-15-1PM-C ADNB025-24-1PM-C ADNB012-48-1PM-C Parameter Min Nom Max Unit 12V Vo Output Overvoltage 13.8 / 18 V Parameter Min Nom Max Unit 15V Vo Output Overvoltage 17.25 / 22.5 V Parameter Min Nom Max Unit 48V Vo Output Overvoltage 55.2 / 72 V Parameter Min Nom Max Unit 24V Vo Output Overvoltage 27.6 / 36 V

Artesyn Embedded Technologies Rev.04.19.16_#1.1 ADNB 60W Series Page 11 Over Current Protection (OCP) ADNB 60W series power supply includes internal current limit circuitry to prevent damage in the event of overload or short circuit. In the event of overloads, it will go to constant current model, the output voltage may deviate from the regulation band but recovery is automatic when the load is reduced to within specified limits. ADNB050-12-1PM-C ADNB040-15-1PM-C ADNB025-24-1PM-C ADNB012-48-1PM-C Parameter Min Nom Max Unit 12V Vo Output Overcurrent 5.1 / / A Parameter Min Nom Max Unit 15V Vo Output Overcurrent 4.08 / / A Parameter Min Nom Max Unit 48V Vo Output Overcurrent 1.275 / / A Parameter Min Nom Max Unit 24V Vo Output Overcurrent 2.55 / / A

Artesyn Embedded Technologies Rev.04.19.16_#1.1 ADNB 60W Series Page 12 Mechanical Specifications Mechanical Drawing (Dimensioning and Mounting Locations)

Artesyn Embedded Technologies Rev.04.19.16_#1.1 ADNB 60W Series Page 13 Weight The ADNB 60W series packing weight is 0.661lb/300g typical.

Table 4. Environmental Specifications:

within other equipment and must not be operated as a stand alone product. Table 5. Safety Certifications for ADNB 60W series power supply system:

15) and CISPR 22 (EN55022) for emissions and relevant sections of EN61000 (IEC 61000) for immunity. The unit is enclosed inside a metal box, tested at full load using resistive load. ground and can be broadband in nature. Table 6. Conducted EMI emission specifications of the ADNB 60W series

Artesyn Embedded Technologies Rev.04.19.16_#1.1 ADNB 60W Series Page 17 Radiated Emissions Unlike conducted EMI, radiated EMI performance in a system environment may differ drastically from that in a stand-alone power supply. It is thus recommended that radiated EMI be evaluated in a system environment. The applicable standard is EN55022 Class B (FCC Part 15). Testing ac-dc convertors as a stand-alone component to the exact requirements of EN55022 can be difficult, because the standard calls for 1m leads to be attached to the input and outputs and aligned such as to maximize the disturbance. In such a set-up, it is possible to form a perfect dipole antenna that very few ac-dc convertors could pass. However, the standard also states that ‘an attempt should be made to maximize the disturbance consistent with the typical application by varying the configuration of the test sample.

Artesyn Embedded Technologies Rev.04.19.16_#1.1 ADNB 60W Series Page 18 Operating Temperature The ADNB 60W series start and operate within stated specifications at an ambient temperature from -25 OC to 70 OC under all load conditions (see below derating curves for other amount of convection and orientation. Derate output current and power by 2.5% per degree above 50 OC. Maximum operating ambient temperature is 70 OC (which implies a 50% derating at max 70 OC ambient). Under convection cooling condition, the maximum output power derates linearly from full load. When input voltage is 90Vac, the maximum output power will derate to 90% full load. Derating Curve

Artesyn Embedded Technologies Rev.04.19.16_#1.1 ADNB 60W Series Page 19 Storage and Shipping Temperature / Humidity The ADNB 60W series can be stored or shipped at temperatures between -40 OC to +85 OC and relative humidity from 10% to 95%, non-condensing. Humidity The ADNB 60W series will operate within specifications when subjected to a relative humidity from 20% to 90% non- condensing. The ADNB 60W series can be stored in a relative humidity from 10% to 95% non-condensing. Vibration The ADNB 60W series will pass the following vibration specifications: Acceleration 2 gRMS Frequency Range 10-500 Hz Duration 10 mins Direction 3 mutually perpendicular axis PSD Profile SLOPE PSD FREQ dB/oct g2/Hz 10-500 Hz --- ---

Artesyn Embedded Technologies Rev.04.19.16_#1.1 ADNB 60W Series Page 20 Application Notes Block Diagram DC OK Relay Contact Contact Close When the output voltage reaches the adjusted output voltage Contact Open When the output voltage drop below 90% o utput voltage Contact Ratings(max.) 30V/1A resistive load

For more information: www.artesyn.com/power For support: productsupport.ep@artesyn.com Rev.04.19.16_#1.1 ADNB 60W Series Page 21 Output Ripple and Noise Measurement The setup outlined in the diagram below has been used for output voltage ripple and noise measurements on the ADNB 60W series . When measuring output ripple and noise, a scope jack in parallel with a 0.1uF ceramic chip capacitor, and a 47uF aluminum electrolytic capacitor should be used. Oscilloscope should be set to 20MHz bandwidth for this measurement.