Features
Rich set of basic functions Compact system providing high-precision bus isolation analog I/O. This product is a control signal(Isolation TTL level 6 points) of analog input(16bits, 8ch), analog output(16bits, 2ch), analog I/O. Digital inputs (Isolation TTL level four points), digital outputs (Isolation TTL level four points), and a counter (32-bit, Isolation TTL level one point) common to the three models. Bus isolation between PC and external I/O signals by a digital isolator Isolation between PC and external I/O circuit by a digital isolator improves noise tolerance. Substantial control functions Capable of analog input/output in either time-based mode or external- signal synchronous mode. Filter function facilitating external signal connection Digital filters provided for external control analog I/O signals, preventing chattering Buffer memory The analog inputs and outputs each have their own buffer memory. You can also perform analog input and output in the background, independent of software and the current status of the PC. Software-based calibration function Calibration of analog input/output can be all performed by software. Apart from the adjustment information prepared before shipment, additional adjustment information can be stored according to the use environment. Exchangeable Low Profile size and standard size slots Support for both of Low Profile size and standard size slots (interchangeable with a bundled bracket). Supported to the data logger software [C-LOGGER] (Analog input only) Supporting the data logger software [C-LOGGER] that enables the graph display of recorded signal data, file saving, and dynamic transfer to the spreadsheet software program “Excel” Plug-ins for the dedicated libraries, the board also supports MATLAB and LabVIEW. We offer a dedicated library [ML-DAQ], which allows you to use this product on MATLAB by the MathWorks as well as another dedicated library [VI-DAQ], which allows you to use the product on LabVIEW. These dedicated libraries are available, free of charge (downloadable), on our web site. Specification Item Specifications Analog input Isolated specification Bus-Isolated Input type Single-Ended Input Number of input channels 8ch Input range Bipolar ±10V Absolute max. input voltage ±20V Input impedance 1MΩ or more Resolution 16bit Non-Linearity error *1*2 ±16LSB Conversion speed 10µsec/ch*3 [100KSPS]*4 Buffer memory 1k Word Conversion start trigger Software / external trigger Conversion stop trigger Number of sampling times / external trigger/software External start signal Isolation TTL level (Rising or falling edge can be selected by software) Digital filter (1µsec can be selected by software) External stop signal Isolation TTL level (Rising or falling edge can be selected by software) Digital filter (1µsec can be selected by software) External clock signal Isolation TTL level (Rising or falling edge can be selected by software) Analog output Isolated specification Bus-Isolated Number of output channels 2ch Output range Bipolar ±10V Absolute max. input currency ±5mA Output impedance 1Ω or less Resolution 16bit Non-Linearity error *1 ±5LSB Conversion speed 10µsec [100KSPS]*4 Buffer memory 1k Word Conversion start trigger Software / external trigger Conversion stop trigger Number of sampling times / external trigger/software External start signal Isolation TTL level (Rising or falling edge can be selected by software) Digital filter (1µsec can be selected by software) External stop signal Isolation TTL level (Rising or falling edge can be selected by software) Digital filter (1µsec can be selected by software) External clock signal Isolation TTL level (Rising or falling edge can be selected by software) *1: The non-linearity error means an error of approximately 0.1% occurs over the maximum range at 0°C and 50°C ambient temperature. *2: At the time of the source use of a signal which built in the high-speed operational amplifier. *3: The required time is indicated in the analog to digital translation of one channel. When AD of two or more channels is converted, time of the a few minutes of the channel is necessary. Conversion time = Number of conversion channelsx10µsec *4: SPS = Samplings Per Second. The number of data that can be converted in one second is shown.
Ver.1.02 AIO-160802LI-PE 2 Item Specifications Digital I/O Number of input channels Isolated input 4ch (TTL level positive logic) Number of output channels Isolated input 4ch (TTL level positive logic) Counter Number of channels 1ch Counting system Up count Max. count FFFFFFFFh (Binary data,32bit) Number of external inputs
2 Isolation TTL level (Gate/Up)
Gate (positive logic/level), Up (Rising edge) Number of external outputs
1 Isolation TTL level Count match output (positive logic,
pulse output) Response frequency 1MHz (Max.) Common section I/O address 64 ports Interruption level Errors and various factors, One interrupt request line as INTA Connector 10250-52A2JL[3M] Power consumption 5VDC 680mA (Max.) Operating condition 0 - 50°C, 10 - 90%RH (No condensation) PCI bus specification 32bit, 33MHz, Universal key shapes supported *5 Dimension (mm) 121.69 (L) x 63.41 (H) Weight 65g Dimensions Support Software Windows version of analog I/O driver API-AIO(WDM) [Stored on the bundled disk driver library API-PAC(W32)] The API-AIO(WDM) is the Windows version driver library software that provides products in the form of Win32 API functions (DLL). Various sample programs such as Visual Basic and Visual C++, etc and diagnostic program *1useful for checking operation is provided. For more details on the supported OS, applicable language and new information, please visit the CONTEC’s Web site. Linux version of analog I/O driver API-AIO(LNX) [Stored on the bundled disk driver library API-PAC(W32)] The API-AIO(LNX) is the Linux version driver software which provides device drivers (modules) by shared library and kernel version. Various sample programs of gcc are provided. For more details on the supported OS, applicable language and new information, please visit the CONTEC’s Web site. Data Logger Software C-LOGGER [Stored on the bundled disk driver library API-PAC(W32)] C-LOGGER is a data logger software program compatible with our analog I/O products. This program enables the graph display of recorded signal data, zoom observation, file saving, and dynamic transfer to the spreadsheet software “Excel”. No troublesome programming is required. For more details on the supported OS, applicable language and new information, please visit the CONTEC’s Web site. Data Acquisition library for MATLAB ML-DAQ (Available for downloading (free of charge) from the CONTEC web site.) This is the library software which allows you to use our analog I/O device products on MATLAB by the MathWorks. Each function is offered in accordance with the interface which is integrated in MATLAB’s Data Acquisition Toolbox. For more details on the supported OS, applicable language and new information, please visit the CONTEC’s Web site. Data acquisition VI library for LabVIEW VI-DAQ (Available for downloading (free of charge) from the CONTEC web site.) This is a VI library to use in National Instruments LabVIEW. VI-DAQ is created with a function form similar to that of LabVIEW's Data Acquisition VI, allowing you to use various devices without complicated settings. For more details on the library and download of VI-DAQ, please visit the CONTEC’s Web site. Packing List Board [ADAI16-8/2(LPCI)L] …1 First step guide … 1 Disk *1 [API-PAC(W32)] …1 Standard size bracket …1 Warranty Certificate …1 Serial Number Label …1 *1 The bundled disk contains the driver software and User’s Guide. List of Options Shield Cable with 50-Pin Mini-Ribbon Connectors at either Ends :PCB50PS-0.5P (0.5m) :PCB50PS-1.5P (1.5m) Shield Cable with 50-Pin Mini-Ribbon Connector at one End :PCA50PS-0.5P (0.5m) :PCA50PS-1.5P (1.5m) Screw Terminal Unit (M3 x 50P) :EPD-50A *1*6 Buffer Amplifier Box for Analog Input Boards (8ch type) :ATBA-8L *1*2*3*4 Buffer Amplifier Box for Analog Input Boards (16ch type) :ATBA-16L *1*2*3 BNC Terminal Unit (for analog input 8ch) :ATP-8L *1*5 *1 PCB50PS-0.5P or PCB50PS-1.5P optional cable is required separately. *2 Only ADAI16-8/2(LPCI)L, ADI16-16(LPCI)L can be used. *3 An external power supply is necessary (optional AC adaptor POA200-20 prepared.) *4 As for the ADI16-16(LPCI)L, capable of using the analog input of up to 8ch. *5 Capable of using the analog input of up to 8ch, and analog output of up to 2ch. *6 “Spring-up” type terminal is used to prevent terminal screws from falling off. * Check the CONTEC’s Web site for more information on these options. How to connect the connectors Connector shape To connect an external device to this board, plug the cable from the device into the interface connector (CN1) shown below. The standard outside dimension(L) is the distance from the end of the board to the outer surface of the slot cover. [mm] 121.69(L) 63.41(H) - Connector used 50-pin mini-ribbon connector 10250-52A2JL[mfd.by 3M] - Applilcable connector 10150-6000EL[mfd. by 3M] CN1 Interface connector (CN1)
Ver.1.02 AIO-160802LI-PE 3 Connector Pin Assignment Pin Assignments of ADAI16-8/2(LPCI)L Interface Connector (CN1) Analog Input00 - Analog Input07 Analog input signal. The numbers correspond to channel numbers. Analog Output00 - Analog Output01 Analog output signal. The numbers correspond to channel numbers. Analog Ground Common analog ground for analog I/O signals. AI External Start Trigger Input External trigger input for starting analog input sampling. AI External Stop Trigger Input External trigger input for stopping analog input sampling. AI External Sampling Clock Input External sampling clock input for analog input. AO External Start Trigger Input External trigger input for starting analog output sampling. AO External Stop Trigger Input External trigger input for stopping analog output sampling. AO External Sampling Clock Input External sampling clock input for analog output. Digital Input00 - Digital Input03 Digital input signal. Digital Output00 - Digital Output03 Digital output signal. Counter Gate Control Input Gate control input signal for counter. Counter Up Clock Input Count-up clock input signal for counter. Counter Output Counter output signal. Digital Ground Common digital ground for digital I/O signals, external trigger inputs, external sampling clock inputs, and counter I/O signals. Reserved Reserved pin. N.C. No connection to this pin. CAUTION - Do not connect any of the outputs and power outputs to the analog or digital ground. Neither connect outputs to each other. Doing either can result in a fault. - If analog and digital ground are shorted together, noise on the digital signals may affect the analog signals. Accordingly, analog and digital ground should be separated. - Leave "Reserved" pins unconnected. Connecting these pins may cause a fault in the board. Analog Input Signal Connection Single-ended Input The following figure shows an example of flat cable connection. Connect separate signal and ground wires for each analog input channel on CN1. Single-ended Input Connection (Flat Cable) The following figure shows an example of shield cable connection. Use shielded cable if the distance between the signal source and board is long or if you want to provide better protection from noise. For each analog input channel on CN1, connect the core wire to the signal line and connect the shielding to ground. Single-ended Input Connection (Shield Cable) *1 The number of channels depends on each board. The ADAI16-8/2(LPCI)L has eight channels. CAUTION - If the signal source contains over 1MHz signals, the signal may effect the cross-talk noise between channels. - If the board and the signal source receive noise or the distance between the board and the signal source is too long, data may not be input properly. - An input analog signal should not exceed the maximum input voltage (relate to the board analog ground). If it exceeds the maximum voltage, the board may be damaged. - Connect all the unused analog input channels to analog ground. - The signal connected to an input pin may fluctuate after switching of the multiplexer. If this occurs, shorten the cable between the signal source and the analog input pin or insert a high- speed amplifier as a buffer between the two to reduce the fluctuation. - An input pin may fail to obtain input data normally when the signal source connected to the pin has high impedance. If this is the case, change the signal source to one with lower output impedance or insert a high-speed amplifier buffer between the signal source and the analog input pin to reduce the effect. - Analog ground of CN1 is isolated from the ground in the PC. Analog Output Signal Connection This section shows how to connect the analog output signal by using a flat cable or a shielded cable. The following figure shows an example of flat cable connection. Connect the signal source and ground to the CN1 analog output. Analog Output Connection (Flat Cable) The following figure shows an example of shield cable connection. Use shielded cable if the distance between the signal source and board is long or if you want to provide better protection from noise. For each analog input channel on CN1, connect the core wire to the signal line and connect the shielding to ground. Analog Output Connection (Shield Cable) *2 The number of channels depends on each board. The ADAI16-8/2(LPCI)L has two channels. CAUTION - If the board or the connected wire receives noise, or the distance between the board and the target is long, data may not be outputted properly. - Do not short the analog output signal to analog ground, digital ground, and/or power line. Doing so may damage the board. - Do not connect an analog output signal to any other analog output, either on the board or on an external device, as this may cause a fault on the board. - Analog ground of CN1 is isolated from the ground in the PC. Digital I/O signals, Counter signals and Control signals Connection The following sections show examples of how to connect digital I/O signals, counter I/O signals, and other control I/O signals (external trigger input signals, sampling clock input signals, etc.). All the digital I/O signals and control signals are TTL level signals. Digital Input Connection Digital Output Connection About the counter input control signal Counter Gate Control Input acts as an input that validate or invalidate the input of an external clock for the counter. This function enables the control of an external clock input for the counter. The external N.C. AGND N.C. AGND AI 04 N.C. AI 05 N.C. AGND AGND AI 06 N.C. AI 07 N.C. AO START AO STOP AO EXCLK DGND DO 00 DO 01 DO 02 DO 03 DGND CNT UPCLK Reseved AO 00 AGND AO 01 AGND AI 00 N.C. AI 01 N.C. AGND AGND AI 02 N.C. AI 03 N.C. AI START AI STOP AI EXCLK DGND DI 00 DI 01 DI 02 DI 03 DGND CNT GATE CNT OUT Analog Output 00 Analog Ground ( for AO ) Analog Output 01 Analog Ground ( for AO ) Analog Input 00 Non Connect Analog Input 01 Non Connect Analog Ground ( for AI ) Analog Ground ( for AI ) Analog Input 02 Non Connect Analog Input 03 Non Connect AI External Start Trigger Input AI External Stop Trigger Input AI External Sampling Clock Input Digital Ground Digital Input 00 Digital Input 01 Digital Input 02 Digital Input 03 Digital Ground Counter Gate Control Input Counter Output Non Connect Analog Ground ( for AO ) Non Connect Analog Ground ( for AO ) Analog Input 04 Non Connect Analog Input 05 Non Connect Analog Ground ( for AI ) Analog Ground ( for AI ) Analog Input 06 Non Connect Analog Input 07 Non Connect AO External Start Trigger Input AO External Stop Trigger Input AO External Sampling Clock Inpu Digital Ground Digital Output 00 Digital Output 01 Digital Output 02 Digital Output 03 Digital Ground Counter UP Clock Input Reserved Analog Input 0..15*1 Analog Ground BOARD CN1 Cable Signal Source Analog Ground Shield cable Analog Input 0..15*1 BOARD CN1 Signal Source Analog Output 0..3*2 Analog Ground BOARD CN1 Cable Target Analog Ground Shield cable Analog Output 0..3*2 BOARD CN1 Target Digital Input Digital Ground BOARD CN1 Cable Target10kΩ Digital Ground BOARD CN1 Cable TargetDigital Output IOL=16mA
Ver.1.02 AIO-160802LI-PE 4 clock for the counter is effective when input is "High", and invalid when input is "Low". If unconnected, it is a pull-up in the board (card) and remains "High". Therefore the external clock for the counter is effective when the counter gate control input is not connected. CAUTION - Do not short the output signals to analog ground, digital ground, and/or power line. Doing so may damage the board. - Do not connect a digital output signal to any other digital output, either on the board or on an external device, as this may cause a fault on the board. - Analog ground of CN1 is isolated from the ground in the PC. Block Diagram