Features

Ver.1.12 ADA16-8/2(LPCI)L 2 (2/2) Item Specification Digital I/O Number of input channels Unisolated input 4ch (TTL level positive logic) Number of output channels Unisolated output 4ch (TTL level positive logic) Counter Number of channels 1ch Counting system Up count Max. count FFFFFFFFh (Binary data,32bit) Number of external inputs 2 TTL level (Gate/Up)/ch Gate (High level), Up (Rising edge) Number of external outputs TTL level Count match output (positive logic, pulse output) Response frequency 10MHz (Max.) Common section I/O address 64 ports Interruption level Errors and various factors, One interrupt request line as INT A Connector 10250-52A2JL[3M] Power consumption 5VDC 380mA (Max.) Operating condition 0 - 50°C, 10 - 90%RH (No condensation) PCI bus specification 32bit, 33MHz, Universal key shapes supported *3 Dimension (mm) 121.69 (L) x 63.41 (H) Weight 60g *1 The non-linearity error means an error of approximately 0.1% occurs over the maximum range at 0°C and 50°C ambient temperature. *2 At the time of the source use of a signal which built in the high-speed operational amplifier. *3 This board requires power supply at +5V from an expansion slot (it does not work on a machine with a +3.3V power supply alone). Board Dimensions Windows version of analog I/O driver API-AIO(WDM) [Stored on the bundled disk driver library API-PAC(W32)] The API-AIO(WDM) is the Windows version driver library software that provides products in the form of Win32 API functions (DLL). Various sample programs such as Visual Basic and Visual C++, etc and diagnostic program *1useful for checking operation is provided. For more details on the supported OS, applicable language and new information, please visit the CONTEC’s Web site. Linux version of analog I/O driver API -AIO(LNX) [Stored on the bundled disk driver library API-PAC(W32)] The API-AIO(LNX) is the Linux version driver software which provides device drivers (modules) by shared library and kernel version. Various sample programs of gcc are provided. For more details on the supported OS, applicable language and new information, please visit the CONTEC’s Web site. Data Logger Software C-LOGGER [Stored on the bundled disk driver library API-PAC(W32)] C-LOGGER is a data logger software program compatible with our analog I/O products. This program enables the graph display of recorded signal data, zoom observation, file saving, and dynamic transfer to the spreadsheet software “Excel”. No troublesome programming is required. For more details on the supported OS, applicable language and new information, please visit the CONTEC’s Web site. Data Acquisition library for MATLAB ML-DAQ (Available for downloading (free of charge) from the CONTEC web site.) This is the library software which allows you to use our analog I/O device products on MATLAB by the MathWorks. Each function is offered in accordance with the interface which is integrated in MATLAB’s Data Acquisition Toolbox. For more details on the supported OS, applicable language and new information, please visit the CONTEC’s Web site. Data acquisition VI library for LabVIEW VI -DAQ (Available for downloading (free of charge) from the CONTEC web site.) This is a VI library to use in National Instruments LabVIEW. VI-DAQ is created with a function form similar to that of LabVIEW's Data Acquisition VI, allowing you to use various devices without complicated settings. For more details on the library and download of VI-DAQ, please visit the CONTEC’s Web site. Cable (Option) Shield Cable with 50-Pin Mini-Ribbon Connectors at either Ends : PCB50PS-0.5P (0.5m) : PCB50PS-1.5P (1.5m) Shield Cable with 50-Pin Mini-Ribbon Connector at one End : PCA50PS-0.5P (0.5m) : PCA50PS-1.5P (1.5m) Accessories (Option) Screw Terminal Unit (M3 x 50P) : EPD-50A *1 *6 Buffer Amplifier Box for Analog Input Boards (8ch type) : ATBA-8L *1*3 Buffer Amplifier Box for Analog Input Boards (16ch type) : ATBA-16L *1*3 BNC Terminal Unit (for analog input 8ch) : ATP-8L *1*5 *1 PCB50PS-0.5P or PCB50PS-1.5P optional cable is required separately. *3 An external power supply is necessary (optional AC adaptor POA200-20 prepared.) *5 Capable of using the analog input of up to 8ch, and analog output of up to 2ch. *6 “Spring-up” type terminal is used to prevent terminal screws from falling off. * Check the CONTEC’s Web site for more information on these options. Board [ADA16-8/2(LPCI)L] …1 First step guide … 1 Disk *1 [API-PAC(W32)] …1 Standard size bracket …1 Warranty Certificate …1 Serial Number Label …1 *1 The bundled disk contains the driver software and User’s Guide The standard outside dimension(L) is the distance from the end of the board to the outer surface of the slot cover. [mm] 121.69(L) 63.41(H) Cable & Connector Accessories Packing List Support Software

Ver.1.12 ADA16-8/2(LPCI)L 3 Connector shape To connect an external device to this board, plug the cable from the device into the interface connector (CN1) shown below. * Please refer to page 2 for more information on the supported cable and accessories. Connector Pin Assignment Pin Assignments of Interface Connector(CN1) Analog Input00 - Analog Input07 Analog input signal. The numbers correspond to channel numbers. Analog Output00 - Analog Output01 Analog output signal. The numbers correspond to channel numbers. Analog Ground Common analog ground for analog I/O signals. AI External Start Trigger Input External trigger input for starting analog input sampling. AI External Stop Trigger Input External trigger input for stopping analog input sampling. AI External Sampling Clock Input External sampling clock input for analog input. AO External Start Trigger Input External trigger input for starting analog output sampling. AO External Stop Trigger Input External trigger input for stopping analog output sampling. AO External Sampling Clock Input External sampling clock input for analog output. Digital Input00 - Digital Input03 Digital input signal. Digital Output00 - Digital Output03 Digital output signal. Counter Gate Control Input Gate control input signal for counter. Counter Up Clock Input Count-up clock input signal for counter. Counter Output Counter output signal. Digital Ground Common digital ground for digital I/O signals, external trigger inputs, external sampling clock inputs, and counter I/O signals. Reserved Reserved pin. N.C. No connection to this pin. Do not connect any of the outputs and power outputs to the analog or digital ground. Neither connect outputs to each other. Doing either can result in a fault. If analog and digital ground are shorted together, noise on the digital signals may affect the analog signals. Accordingly, analog and digital ground should be separated. Leave "Reserved" pins unconnected. Connecting these pins may cause a fault in the board. Analog signal input types are divided into single- ended input and differential input. This board uses single-ended input fixed. The following examples show how to connect analog input signals using a flat cable and a shielded cable. Single-ended Input The following figure shows an example of flat cable connection. Connect separate signal and ground wires for each analog input channel on CN1. Single-ended Input Connection (Flat Cable) The following figure shows an example of shield cable connection. Use shielded cable if the distance between the signal source and board is long or if you want to provide better protection from noise. For each analog input channel on CN1, connect the core wire to the signal line and connect the shielding to ground. Single-ended Input Connection (Shield Cable) * The number of channels depends on each board. This product has eight channels. 8 single-end Analog Inputs

4 Digital Input / 4 Digital Output

2 Analog Outputs

  • Connector used 50-pin mini-ribbon connector 10250-52A2JL[mfd.by 3M] - Applilcable connector 10150-6000EL[mfd. by 3M] CN1 Interface connector (CN1) N.C. AGND N.C. AGND AI 04 N.C. AI 05 N.C. AGND AGND AI 06 N.C. AI 07 N.C. AO START AO STOP AO EXCLK DGND DO 00 DO 01 DO 02 DO 03 DGND CNT UPCLK Reseved AO 00 AGND AO 01 AGND AI 00 N.C. AI 01 N.C. AGND AGND AI 02 N.C. AI 03 N.C. AI START AI STOP AI EXCLK DGND DI 00 DI 01 DI 02 DI 03 DGND CNT GATE CNT OUT Analog Output 00 Analog Ground ( for AO ) Analog Output 01 Analog Ground ( for AO ) Analog Input 00 Non Connect Analog Input 01 Non Connect Analog Ground ( for AI ) Analog Ground ( for AI ) Analog Input 02 Non Connect Analog Input 03 Non Connect AI External Start Trigger Input AI External Stop Trigger Input AI External Sampling Clock Input Digital Ground Digital Input 00 Digital Input 01 Digital Input 02 Digital Input 03 Digital Ground Counter Gate Control Input Counter Output Non Connect Analog Ground ( for AO ) Non Connect Analog Ground ( for AO ) Analog Input 04 Non Connect Analog Input 05 Non Connect Analog Ground ( for AI ) Analog Ground ( for AI ) Analog Input 06 Non Connect Analog Input 07 Non Connect AO External Start Trigger Input AO External Stop Trigger Input AO External Sampling Clock Inpu Digital Ground Digital Output 00 Digital Output 01 Digital Output 02 Digital Output 03 Digital Ground Counter UP Clock Input Reserved CAUTION Analog Input 0..15*1 Analog Ground BOARD CN1 Cable Signal Source Analog Ground Shield cable Analog Input 0..15*1 BOARD CN1 Signal Source How to connect the connectors Block Diagram Analog Input Signal Connection

Ver.1.12 ADA16-8/2(LPCI)L 4 If the signal source contains over 1MHz signals, the signal may effect the cross-talk noise between channels. If the board and the signal source receive noise or the distance between the board and the signal source is too long, data may not be input properly. An input analog signal should not exceed the maximum input voltage (relate to the board analog ground). If it exceeds the maximum voltage, the board may be damaged. Connect all the unused analog input channels to analog ground. The signal connected to an input pin may fluctuate after switching of the multiplexer. If this occurs, shorten the cable between the signal source and the analog input pin or insert a high-speed amplifier as a buffer between the two to reduce the fluctuation. An input pin may fail to obtain input data normally when the signal source connected to the pin has high impedance. If this is the case, change the signal source to one with lower output impedance or insert a high-speed amplifier buffer between the signal source and the analog input pin to reduce the effect. This section shows how to connect the analog output signal by using a flat cable or a shielded cable. The following figure shows an example of flat cable connection. Connect the signal source and ground to the CN1 analog output. Analog Output Connection (Flat Cable) The following figure shows an example of shield cable connection. Use shielded cable if the distance between the signal source and board is long or if you want to provide better protection from noise. For each analog input channel on CN1, connect the core wire to the signal line and connect the shielding to ground. Analog Output Connection (Shield Cable) * The number of channels depends on each board. This product has two channels. If the board or the connected wire receives noise, or the distance between the board and the target is long, data may not be outputted properly. For analog output signal, the current capacity is ±3mA (Max.). Check the specification of the connected device before connecting the board. Do not short the analog output signal to analog ground, digital ground, and/or power line. Doing so may damage the board. Do not connect an analog output signal to any other analog output, either on the board or on an external device, as this may cause a fault on the board. The following sections show examples of how to connect digital I/O signals, counter I/O signals, and other control I/O signals (external trigger input signals, sampling clock input signals, etc.). All the digital I/O signals and control signals are TTL level signals. Digital Input Connection Digital Output Connection About the counter input control signal Counter Gate Control Input (refer to the page 3 Connector Pin Assignment) acts as an input that validate or invalidate the input of an external clock for the counter. This function enables the control of an external clock input for the counter. The external clock for the counter is effective when input is "High", and invalid when input is "Low". If unconnected, it is a pull-up in the board (card) and remains "High". Therefore the external clock for the counter is effective when the counter gate control input is not connected. Do not short the output signals to analog ground, digital ground, and/or power line. Doing so may damage the board. CAUTION Analog Output 0..3*2 Analog Ground BOARD CN1 Cable Target Analog Ground Shield cable Analog Output 0..3*2 BOARD CN1 Target CAUTION 10kΩ Digital Input Digital Ground BOARD CN1 Cable Target Digital Ground BOARD CN2 Cable TargetDigital Output IOL=24mA CAUTION Digital I/O signals, Counter signals and Control signals Connection Analog Output Signal Connection