V4.00/EN/00311468/2021-04-12 Page 1/10Data Sheet 902020 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUD‰H )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -802,QVWUXPHQW&R/WG -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF 0\\HUV5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 90202000T10Z001K000 Screw-in RTD temperature probe With form B terminal head

  • For temperatures between -50 to +600 °C
  • Comes with replac eable measuring insert
  • Available as single and double RTD temperature probe
  • Terminal head form B, BUZ, BUZH, BBK, AB7, and KGI-1
  • Available with transmitter Brief description Screw-in RTD temperature probes are predominantly used for measuring temperatures in liquids and gases. The reliable tightnes s of this installation type und er negative pressure as well as overpressure is an important selection criterion. The application areas are, among others, in air- conditioning and refrigeration technology as well heater and furnace construction and apparatus engineering. The terminal head is suitable for temperatures up to +100 °C. In addition to the standard form B connection head, the BUZ, BUZH, BBK, AB7, and KGI-1 design types are also available. A Pt100 temperature sensor according to DIN EN 60751:2009 / IEC 60751:2008 (temperature coefficient α = 3.850 × 10-3 °C-1), class B in two-wire circuit, is used as standard as the measur- ing insert; versions with Pt500 or Pt1000 are also possible. The connection is optionally possible in a three-wire and four-wire circuit. A transmitter can be integrated into the terminal head as an option. Approvals and approval marks

V4.00/EN/00311468/2021-04-12 Page 2/10Data Sheet 902020 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUD‰H )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -802,QVWUXPHQW&R/WG -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF 0\\HUV5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 90202000T10Z001K000 Technical data Terminal head Form B DIN EN 50446, aluminum die-cast, M20 × 1.5; I P65, ambient temperature -40 to +100 °C Form BUZ, aluminum die-cast, M20 × 1.5; IP65, ambient temperature -40 to +100 °C Form BUZH, aluminum die-cast, M20 × 1.5; IP65, ambient temperature -40 to +100 °C Form BBK, plastic, M20 × 1.5; IP54, ambient temperature -30 to +130°C Caution: reduced ambient temperature when using transmitters, data sheets 707010, 707030, 707050, 707060, and 707080 Insofar as the design type allows it, yellow terminal heads are used for SIL and PL applications (extra codes 658 or 659). Exceptions to this are probes for use in alkaline environments and probes where it is strictly necessary that they are PWIS-free. Extension tube Stainles s steel 1.4571, length 130 mm Process connection Thread, stainless steel 1.4571 Protection tube Stainless s teel 1.4571, Ø 9 mm, Ø 11 mm, Ø 12 mm Measuring insert Exchangeable, P t100 temperature sensor, DIN EN 60751:2009 / IEC 60751:2008, class B, two- wire circuit Response times t 0.9 approx. 50 s, in water 0.2 m/s, Ø 9 mm Vibration resistance 20 g (pea k-to-peak) at the tip of the measuring insert Transmitters Progra mmable transmitter, data sheet 707010 Analog transmitter, data sheet 707030 Programmable transmitter, data sheet 707050 Programmable two-channel transmitter with HART®/SIL, data sheet 707080 Programmable Wtrans B head transmitter with wireless data transmission, data sheet 707060 (suitable Wtrans receivers according to data sheet 902931) Accessories Thermowell, data sheet 909710

V4.00/EN/00311468/2021-04-12 Page 3/10Data Sheet 902020 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUD‰H )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -802,QVWUXPHQW&R/WG -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF 0\\HUV5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 90202000T10Z001K000 Functional safety Approvals and approval marks With this product, JUMO provides a number of different possibilities in terms of functional safety to realize a completely or partially certified solution. If you require consulting with regard to the safety integrity level (SIL) or performance level (PL), you can contact us at sil@jumo.net to arrange a personal appointment. The safety data (MTBF, MTTFD, and FIT values) can also be accessed on demand for this item under sensors@jumo.net. SIL Test facility TÜV SÜD Certificate/test no. Z10 17 05 01028 001 Inspection basis IEC 61508-1(ed.2) IEC 61508-2(ed.2) IEC 61508-3(ed.2) IEC 61508-4(ed.2) Valid for in conjunction with two- channel transmitter JUMO dTRANS T07 B SIL (type 707081) SIL QUALIFIED Test facility - Certificate/test no. - Inspection basis - Valid for Extra codes 658/659 in c onjunction with declaration of manufacturer PL QUALIFIED Test facility - Certificate/test no. - Inspection basis - Valid for Extra codes 658/659 in c onjunction with declaration of manufacturer

V4.00/EN/00311468/2021-04-12 Page 4/10Data Sheet 902020 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUD‰H )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -802,QVWUXPHQW&R/WG -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF 0\\HUV5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 90202000T10Z001K000 Dimensions RTD temperature probe dimensions Insofar as the design type allows it, yellow terminal heads are used for SIL and PL applications (extra codes 658 or 659). Exc eptions to this are probes for use in alkaline environments and probes where it is strictly necessary that they are PWIS-free. Basic type 902020/10 Basic type 902020/11 Basic type 902020/20 Basic type 902020/21 G 130 EL D Ø12 G 130 EL EL G D Ø12 G EL

V4.00/EN/00311468/2021-04-12 Page 5/10Data Sheet 902020 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUD‰H )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -802,QVWUXPHQW&R/WG -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF 0\\HUV5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 90202000T10Z001K000 Dimensions of the terminal heads Wtrans B – head transmitter with wireless data transmission Terminal head form BUZ Terminal head form BUZH Terminal head form BBK Extra code 320 Extra code 321 Extra code 322 Terminal head form KGI-1 Terminal head form AB7 Extra code 326 Extra code 924 ~ 58~ ~73~ ~ 64~ ~112~ ~ 60~ ~80~ 50~~ 61~ ~ ~ 78~ ~ 91.6~ The Wtrans B head transmitter with wireless data transmission (data sheet 707060) is used in conjunction with a Wtrans receiver (data sheet 902931) for stationary or mobile acquisition of temperatures with RTD temperature probes or thermocouples. The measured values are transmitted wirelessly to the receiver of the Wtrans measuring system. The measured values are displayed on the receiver and are available in digital format on the RS485 interface and as analog outputs. Alternatively, different alarms can be signaled with two relay outputs. This head transmitter, designed for industrial applications, comprises a transmitter with integrat- ed transmission unit and an antenna-battery housing. The transmitter is designed for mounting in form B terminal heads and works in an ambient temperature range of -30 to +85 °C. The radio frequency of the Wtrans measuring system is 868.4 MHz. This frequency is largely im- pervious to external interference and allows data to be transmitted even in harsh industrial envi- ronments. When using the antenna holder for wall mounting with the 3 m antenna cable for the receiver, the open air range is 300 m. A 3.6 V, 2.2 Ah (size AA) lithium battery is used for the head transmitter voltage supply. A setup program is available as an accessory for easy configuration and parameterization of the head transmitter and the Wtrans receiver on a PC. The OnlineChart function can be used option- ally to record the measured values on a PC.

V4.00/EN/00311468/2021-04-12 Page 6/10Data Sheet 902020 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUD‰H )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -802,QVWUXPHQW&R/WG -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF 0\\HUV5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 90202000T10Z001K000 Order details (1) Basic type 902020/10 Screw-in RTD temperature probe with extension tube, continuous protection tube 902020/11 Screw-in RTD temperature probe with extension tube, reduced protection tube insertion length (EL) max. 700 mm (2) Operating temperature (additional versions upon request) x x 386 -50 to +260 °C x x 402 -50 to +400 °C (standard) x x 415 -50 to +600 °C (3) Measuring insert (additional versions upon request) x x 1001 1× Pt100 in three-wire circuit x x 1003 1× Pt100 in two-wire circuit x x 1011 1× Pt100 in four-wire circuit x x 2001 2× Pt100 in three-wire circuit x x 2003 2× Pt100 in two-wire circuit (4) Tolerance class according to DIN EN 60751:2009 / IEC 60751:20 08 (additional versions upon request) x x 1 Class B (standard) (-50 to +500 °C) x x 2 Class A (-30 to +300 °C) (5) Protection tube diameter D x9 Ø 9 m m x 9 Ø 9 mm reduced to Ø 6 mm x1 1 Ø 1 1 m m x 12 Ø 12 mm reduced to Ø 9 mm (6) Insertion length EL in mm (EL up to 1000 mm) x x ... Specification in plain text (7) Process connection (additional versions upon request) x x 104 Screw connection G 1/2 x x 105 Screw connection G 3/4 x x 106 Screw connection G 1 (8) Extra codes x x 000 None x x 306 Extension tube 70 mm (instead of 130 mm) x x 320 Terminal head form BUZ x x 321 Terminal head form BUZH x x 322 Terminal head form BBK x x 326 Terminal head form KGI-1 x x 424 Terminal head with M12 machine connector (can only be sele cted in the case of measuring inserts with max. 4 wires, e.g. 1003, 1011, or 2003) x x 924 Terminal head form AB7 with LC plug-in display (only in conjunction with extra code 866 or 867) x x 925 Terminal head form BUZH with LC plug-in display (only in c onjunction with extra code 866 or 867) x x 330 1× analog transmitter (type 707031 according to data sheet 707030), output 4 to 20 mA, (only for measuring insert 1× Pt100 in two-wire or three-wire circuit, not in conjunction with extra codes 658 or 659) x x 331 1× programmable transmitter (type 707014 according to data sheet 707010), output 4 to 20 mA/20 to 4 mA, (only for measuring insert 1× Pt100, not in conjunction with extra codes 658 or 659, suitable setup program part no. 00605080) x x 333 1× analog transmitter (type 707033 according to data sheet 707030), output 0 to 10 V, (only for measuring insert 1× Pt100 in two-wire or three-wire circuit, not in conjunction with extra codes 658 or 659) GD EL GEL D

V4.00/EN/00311468/2021-04-12 Page 7/10Data Sheet 902020 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUD‰H )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -802,QVWUXPHQW&R/WG -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF 0\\HUV5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 90202000T10Z001K000 Note: For extra code transmitter please specify measuring range and, if applicable, output signal in plain text. x x 334 2× analog transmitter s (type 707031 according to data sheet 707030), output 4 to 20 mA, (only for measuring insert 2× Pt100 in two-wire or three-wire circuit and with extra code 321, not in conjunction with extra codes 658 or 659) x x 335 2× programmable transmi tters (type 707014 according to data sheet 707010), output 4 to 20 mA/20 to 4 mA, (only for measuring insert 2× Pt100 and with extra code 321, not in conjunction with extra codes 658 or 659, suitable setup program part no. 00605080) x x 337 2× analog transmitters (ty pe 707033 according to data sheet 707030), output 0 to 10 V, (only for measuring in- sert 2× Pt100 in two-wire or three-wire circuit and with extra code 321, not in conjunction with extra codes 658 or 659) x x 550 1× programmable transmitter (type 707050 according to data sheet 707050), output 4 to 20 mA/20 to 4 mA (USB), (only for measuring insert 1× Pt100, not in conjunction with extra codes 658 or 659, suitable setup pro- gram part no. 00574959) x x 551 2× programmable transmi tters (type 707050 according to data sheet 707050), output 4 to 20 mA/20 to 4 mA (USB), (only for measuring insert 2× Pt100 and with extra code 321, not in conjunction with extra codes 658 or 659, suitable setup program part no. 00574959) x x 859 1× programmable head transmi tter Wtrans B with wireless data transmission (type 707060 according to data sheet 707060), (not in conjunction with extra codes 658 or 659, suitable setup program part no. 00488887) x x 866 1× programmable two-channel transmitter with HART® (type 7 07080 according to data sheet 707080), output 4 to 20 mA, (not in conjunction with extra codes 658 or 659, suitable software available for free – Device Type Manager (DTM) for PACTware) x x 867 1× programmable two-channel t ransmitter with HART®/SIL (type 707081 according to data sheet 707080), out- put 4 to 20 mA, (not in conjunction with extra codes 658 or 659, suitable software available for free – Device Type Manager (DTM) for PACTware) x x 658 SIL and PL compatible (only i n conjunction with JUMO SIL-certified safety temperature limiters and monitors according to data sheet 701150, not in conjunction with extra codes 330, 331, 333, 334, 335, 337, 550, 551, 859, 866, and 867) x x 659 SIL and PL compatible (only in conjunction with dTRANS T06 temperature transmitter according to data sheet 707071, not in conjunction with extra codes 330, 331, 333, 334, 335, 337, 550, 551, 859, 866, and 867) Order code - - - - - - / , ... a a List extra codes in sequence and separate using commas. Order example 902020/10 - 402 - 1003 - 1 - 9 - 250 - 104 / 000

V4.00/EN/00311468/2021-04-12 Page 8/10Data Sheet 902020 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUD‰H )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -802,QVWUXPHQW&R/WG -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF 0\\HUV5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 90202000T10Z001K000 (1) Basic type 902020/20 Screw-in RTD temperature probe without extension tube, continuous protection tube 902020/21 Screw-in RTD temperature probe without extension tube, reduced protection tube, insertion length (EL) max. 700 mm (2) Operating temperature (additional versions upon request) x x 386 -50 to +260 °C x x 402 -50 to +400 °C (standard) x x 415 -50 to +600 °C (3) Measuring insert (additional versions upon request) x x 1001 1× Pt100 in three-wire circuit x x 1003 1× Pt100 in two-wire circuit x x 1011 1× Pt100 in four-wire circuit x x 2001 2× Pt100 in three-wire circuit x x 2003 2× Pt100 in two-wire circuit (4) Tolerance class according to DIN EN 60751:2009 / IEC 60751:20 08 (additional versions upon request) x x 1 Class B (standard) (-50 to +500 °C) x x 2 Class A (-30 to +300 °C) (5) Protection tube diameter D x9 Ø 9 m m x 9 Ø 9 mm reduced to Ø 6 mm x1 1 Ø 1 1 m m x 12 Ø 12 mm reduced to Ø 9 mm (6) Insertion length EL in mm (EL up to 1000 mm) x x ... Specification in plain text (7) Process connection (additional versions upon request) x x 104 Screw connection G 1/2 x x 105 Screw connection G 3/4 x x 106 Screw connection G 1 (8) Extra codes x x 000 None x x 320 Terminal head form BUZ x x 321 Terminal head form BUZH x x 322 Terminal head form BBK x x 326 Terminal head form KGI-1 x x 424 Terminal head with M12 machine connector (can only be sele cted in the case of measuring inserts with max. 4 wires, e.g. 1003, 1011, or 2003) x x 924 Terminal head form AB7 with LC plug-in display (only in conjunction with extra code 866 or 867) x x 925 Terminal head form BUZH with LC plug-in display (only in c onjunction with extra code 866 or 867) x x 330 1× analog transmitter (type 707031 according to data sheet 707030), output 4 to 20 mA, (only for measuring insert 1× Pt100 in two-wire or three-wire circuit, not in conjunction with extra codes 658 or 659) x x 331 1× programmable transmitter (type 707014 according to data sheet 707010), output 4 to 20 mA/20 to 4 mA, (only for measuring insert 1× Pt100, not in conjunction with extra codes 658 or 659, suitable setup program part no. 00605080) x x 333 1× analog transmitter (type 707033 according to data sheet 707030), output 0 to 10 V, (only for measuring insert 1× Pt100 in two-wire or three-wire circuit, not in conjunction with extra codes 658 or 659) x x 334 2× analog transmitter s (type 707031 according to data sheet 707030), output 4 to 20 mA, (only for measuring insert 2× Pt100 in two-wire or three-wire circuit and with extra code 321, not in conjunction with extra codes 658 or 659) GEL D GEL D

V4.00/EN/00311468/2021-04-12 Page 9/10Data Sheet 902020 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUD‰H )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -802,QVWUXPHQW&R/WG -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF 0\\HUV5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 90202000T10Z001K000 Note: For extra code transmitter please specify measuring range and, if applicable, output signal in plain text. Stock versions x x 335 2× programmable transmi tters (type 707014 according to data sheet 707010), output 4 to 20 mA/20 to 4 mA, (only for measuring insert 2× Pt100 and with extra code 321, not in conjunction with extra codes 658 or 659, suitable setup program part no. 00605080) x x 337 2× analog transmitters (ty pe 707033 according to data sheet 707030), output 0 to 10 V, (only for measuring in- sert 2× Pt100 in two-wire or three-wire circuit and with extra code 321, not in conjunction with extra codes 658 or 659) x x 550 1× programmable transmitter (type 707050 according to data sheet 707050), output 4 to 20 mA/20 to 4 mA (USB), (only for measuring insert 1× Pt100, not in conjunction with extra codes 658 or 659, suitable setup pro- gram part no. 00574959) x x 551 2× programmable transmi tters (type 707050 according to data sheet 707050), output 4 to 20 mA/20 to 4 mA (USB), (only for measuring insert 2× Pt100 and with extra code 321, not in conjunction with extra codes 658 or 659, suitable setup program part no. 00574959) x x 859 1× programmable head transmi tter Wtrans B with wireless data transmission (type 707060 according to data sheet 707060), (not in conjunction with extra codes 658 or 659, suitable setup program part no. 00488887) x x 866 1× programmable two-channel transmitter with HART® (type 7 07080 according to data sheet 707080), output 4 to 20 mA, (not in conjunction with extra codes 658 or 659, suitable software available for free – Device Type Manager (DTM) for PACTware) x x 867 1× programmable two-channel t ransmitter with HART®/SIL (type 707081 according to data sheet 707080), out- put 4 to 20 mA, (not in conjunction with extra codes 658 or 659, suitable software available for free – Device Type Manager (DTM) for PACTware) x x 658 SIL and PL compatible (only i n conjunction with JUMO SIL-certified safety temperature limiters and monitors according to data sheet 701150, not in conjunction with extra codes 330, 331, 333, 334, 335, 337, 550, 551, 859, 866, and 867) x x 659 SIL and PL compatible (only in conjunction with dTRANS T06 temperature transmitter according to data sheet 707071, not in conjunction with extra codes 330, 331, 333, 334, 335, 337, 550, 551, 859, 866, and 867) Order code - - - - - - / , ... a a List extra codes in sequence and separate using commas. Order example 902020/20 - 402 - 1003 - 1 - 9 - 250 - 104 / 000 Order code Part no. 902020/10-402-1003-1-9-160-104/000 00055562 902020/10-402-1003-1-9-250-104/000 00055563 902020/10-402-1003-1-9-400-104/000 00055564 902020/10-402-2003-1-9-160-104/000 00055565 902020/10-402-2003-1-9-250-104/000 00055566 902020/10-402-2003-1-9-400-104/000 00055567 902020/10-402-1001-1-9-160-104/330 (0 to 100 °C) 00054616 902020/10-402-1001-1-9-160-104/330 (0 to 200 °C) 00087522 902020/10-402-1001-1-9-250-104/330 (0 to 200 °C) 00087527 902020/10-402-1001-1-9-400-104/331 (0 to 100 °C) 00335111

V4.00/EN/00311468/2021-04-12 Page 10/10Data Sheet 902020 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUD‰H )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -802,QVWUXPHQW&R/WG -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF 0\\HUV5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 90202000T10Z001K000 Accessories Accessories for programmable two-wire transmitter, type 707010 Accessories for programmable two-wire transmitter, type 707050 Accessories for programmable Wtrans B head transmitter with wireless data transmission, type 707060 Accessories for programmable two-channel transmitter with HART®, type 707080 or programmable two-channel transmitter with HART®/SIL, type 707081 Trademark information

  • HART® is a registered trademar k of FieldComm Group Inc., Austin, TX 78759, US. Designation Part no. PC interface with USB/TTL converter 00456352 Special programming (standard measuring range 0 to 100 °C) - Setup program on CD-ROM, multilingual 00605080 Designation Part no. Setup program on CD-ROM, multilingual 00574959 USB cable, type A USB connector on Mini-B USB connector, length 3 m 00506252 Designation Part no. Lithium battery 3.6 V, 2.2 Ah (size AA) 00547559 PC interface with USB/TTL converter 00456352 Setup program on CD-ROM, multilingual 00488887 Setup program including OnlineChart on CD-ROM, multilingual 0054 9067 OnlineChart activation 00549188 Designation Part no. HART® modem USB 00443447 JUMO dTRANS T07 B 707080 – Device Type Manager (DTM) software program 00687789