JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc.

6733 Myers Road

East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com Page 1/16 V3.00/EN/00541528 JUMO dTRANS AS 02 Transmitter/controller for standard signals and temperature Brief description The JUMO dTRANS AS 02 is a compact, modular instrument. It is highly flexible (for example 3 slots for optional boards) and capable of performi ng a wide range of tasks. Resistance thermometers Pt100 or Pt1000, NTC/PTC or standard signals 0(4) to 20 mA or 0 to 10 V can be connected to the main input of the JUMO dTRA NS AS 02. The two binary inputs can be used as initiators for actions (for example HOLD, keypad lock). The high-contrast graphic display allows for several options including display of input signal with numbers or as bar graph. Parameters are displayed in plain text for easily comprehensible and reliable operation. The JUMO dTRANS AS 02 can be used as a two-point or three-point controller, a three-point modulating controller, or as a continuous controller. All controller outputs can be configured to P , PI, PD or PID action. The software for the controllers includes parameter set selection, a math module and more. A setup program is available for convenient configuration via PC. The instrument can be integrated into a data networ k by means of an RS422/485 or PROFIBUS-DP interface. Screw terminals on the back are used for the electrical connection. Some applications:

  • Free chlorine, total chlorine, hydrogen peroxide, peracetic acid, chlorine dioxide and ozone in combination with sensors as per data sheet 20263X.  The pH value or redox potential with 2-wi re transmitter JUMO digiLine – intelligent electronics with analog output type 202705/20-86-888.  (Hydrostatic) liquid levels with 2-wire transmitters (level and pressure measuring instruments) as per data sheet 402090 or data sheet 404391.  Flow rate in combination wi th relevant transmitters.  Two temperature measuring points. Special features  Display: mg/l, pH, mV, µS/cm, etc. Special visualizations are also possible with the setup program  A choice of display visualizations: large numbers, bar graph or tendency (trend) display  Integrated calibration routines: 1-point and 2-point  Math and logic module  Calibration logbook  Integrated washing ti mer to control the cleaning equipment  13 operator languages integrated; see order details  Setup program provides: convenient programming, system documentation  Flush-mounted instrument - just 96 mm × 48 mm × 95 mm Block diagram Optional boards A n a l o g i n p u t A n a l o g o u t p u t  Relay D o u b l e r e l a y  PROFIBUS-DP and RS422/485 interface  Datalogger function with RS485 Data Sheet 202553 JUMO dTRANS AS 02, type 202553/01... in panel case JUMO dTRANS AS 02, type 202553/05... in surface-mounted case Approval/approval marks (see Technical data) 20255300T10Z002K000

V3.00/EN/00541528 Page 2/16Data Sheet 202553 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 20255300T10Z002K000 Functional description The instrument is a modularly designed indicator/controller for use in both simple and demanding control tasks. It can be integrated into the PLC via interfaces To make programming and operation easy, all parameters are clearly assigned to levels and displayed in plain text. Operation is protected by a code word. Operation can be adapted on an individual basis be cause parameters can be generally enabled or assigned to the protected area. A setup program for the PC is available as a more convenient config uration option, rather than using the instrument keypad. User data Up to 8 parameters that are frequently changed by the user can be combined in the user level under "Use r data" (via setup program only). Displays and controls (1) Binary outputs (relays) Output active if symbol is visible. (2) Binary input Input closed if symbol is visible. (3) Keypad lock Keys locked if symbol is visible. (4) Alarm message ALARM (flashing): Broken sensor or overrange, etc. AL R1: Controller monitoring alarm from controller channel 1. AL R1: Controller monitoring alarm from controller channel 2. CALIB: Calibration mode active. CALIB (flashing): Calibration timer elapsed. (5) Output mode MAN.: Manual mode active. HOLD: Hold mode active. (6) Top display Measured value and unit of the variable set by parameter "Top display". (6) (8) (7) Display modes The following display modes are available: Normal display In this display meth od the measurements appear in numbers, as usual. Large display This method uses the complete display height. Tendency display In this display a symb ol is added to the numerical value to indicate the direction and speed of change for the measurement value. This can be very usef ul for optimizing the controller, for example. From left to right: Fast, medium and slow rise, steady, slow, medium and fast fall. Bar graph In this display mode, it only takes a glance to ascertain the range for the current measurement. Any scale can be used for the bar graph. Tendency curve (data monitor) The ring buffer contains about 100 measuring points. The sampling and storage rates can be adjusted. (7) Bottom display Measured value and unit of the variable set by parameter "Bottom display". (8) Operating mode MEASURING: Standard measuring mode is active. Boards PSU board (1) This board is always fitted in the instrument and no variations are possible. The board includes the following items:  The voltage supply for the JUMO dTRANS AS 02.  The voltage supply for external 2-wire transmitters.  2 relays with changeover contacts. Main board (2) This board can not be changed subsequently! The main board (AS) has:  The main input for connecting a temperature sensor Pt100, Pt1000, a resistance transmitter or a standard signal 0(4) to 20 mA or 0 to 10 V.  2 binary inputs.  The setup interface (for PC interface adapter). Optional board (1), (2) or (3) These boards are combinable and can be ordered in the following versions:  1 analog input  1 continuous output  1 relay (changeover)  2 relays (NO with common pin) 1 T r i a c ( 1 A ) 1 P h o t o M O S ® relay (0.2 A) The following boards can only be placed in slot 3, either:  Modbus/Jbus  PROFIBUS-DP  Datalogger For versions with a wall-mounted case the (re)placement of the optional boards by the customer is not possible. (1) PSU board (2) Main board (a) Optional board 1 (b) Optional board 2 (c) Optional board 3 c b a

V3.00/EN/00541528 Page 3/16Data Sheet 202553 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 20255300T10Z002K000 Function modes of the main board Main board input 0(4) to 20 mA; 0 to 10 V and Pt100/Pt1000/ NTC/PTC (max. 30 kΩ)/cust. specs. Typical application: Compensation input for temperature compensation of the main measurement variable. Linear scaling Select this mode when the input signal will be displayed linearly. One of the following units is used for display or control: µ S / c m m S / c m m V p H  ppm  Cust. specs. (5 characters) Sensors can be connect ed to the instrument for the following measurement variables, for example:  Free chlorine, chlorine dioxide, ozone, hydrogen peroxide and peracetic acid as per data sheet 202630.  pH value odr Redox potential.  Liquid level measurements.  Flow rate measurements. e t c . The instrument has three calibration options available in this function mode: Z e r o p o i n t  Limit value  Zero point and limit value This allows optimum adaptation of the instrument to the sensor. Conductivity This mode is intended for sensors that make uncorrected standard signals available. µS/ cm or mS/cm are the units used for display or control. Different calibration routines can be activated:  Calibrating the cell constant. Because of manufacturing constraints, the cell constant of a conductivity measuring cell may differ slightly from its nominal value (the value printed on it). Wear or the accumulation of deposits during operation can also cause the cell constant to change. This changes the output signal from the measuring cell. With this instrument, the user has the opportunity to compensate for deviations in the nominal value of the cell constant by manual input (80 to 120 % range) or automatic calibration of the relative cell constant K rel.  Calibrating the temperature coefficient α The conductivity of virtually all solutions is temperature-dependent. To ensure correct measurement both the temperature and the temperature coefficient α [%/K] of the measurement solution must therefore be known. The temperature can either be measured automatically with a Pt100 or Pt1000 temperature probe or the user must set the temperature by hand. The temperature coefficient can be determined automatically by the instrument or entered manually in the 0t o5 . 5% / K r a n g e . Concentration In this mode, the concentration of a liquid can be determined from its uncompensated conductivity. % or "Cust. specs." are the units used for display and control. Concentration measurement: The cell constant can be calibrated. pH or redox Connection option for tr ansmitters that emit an uncalibrated pH or redox standard signal, such as 2-wire transmitter JUMO digiLine – intelligent electronics with analog output type 202705/20-86-888. The dTRANS AS 02 provides the required voltage supply for th is type of 2-wire transmitter. pH: a pH calibration (zer o point or zero point and slope) can be perf ormed, as well as the option of temperature compensation. "pH" display and control variable. Redox: Both relative and absolute calibration are possible (zero point or as a percentage, using reference values). "mV" or "%" display and control variables. Cust. specs. with table Non-linear correlations between the input and output variable can be processed in this mode. Typical applications include measuring the level of liquid in horizontal, cylindrical containers or simp ly measuring the concentration. The input values are processed in a table (max. 20 value pairs). Values can only be entered in the table using the optional setup program. Caustic soda N a O H 0t o1 5% b y w e i g h t NaOH 25 to 50 % by weight Nitric acid HNO 3 0t o2 5% b y w e i g h t HNO3 36 to 82 % by weight Sulfuric acid H2SO4 0t o2 8% b y w e i g h t H2SO4 36 to 85 % by weight H2SO4 92 to 99 % by weight Hydrochloric acid H C l 0t o1 8% b y w e i g h t HCl 22 to 44 % by weight The units used for display and control are: µ S / c m m S / c m  Cust. specs. (5 characters)  Use the offset para meter to adjust the display. Temperature compensation The instrument is able to perform an automatic temperature compensation. The conductivity or resistance of aqueous solutions often depends greatly on the temperature. The instrument provides the following procedures for temperature compensation, depending on the display size:  Off (e.g. USP) L i n e a r A S T M  Natural waters (EN 27888/ISO 7888) Function modes of the optional inputs, "Multi-channel mode" I f a n a l o g i n p u t s h a v e been fitted (optional board), the device wi ll have multi-channel functions. The following signal types can be processed: 0 ( 4 ) t o 2 0 m A 0 t o 1 0 V  Pt100/Pt1000 Sensors that return one of the output signals listed above can be connected to the instrument for the following measurement variables, for example:  Free chlorine, chlorine dioxide, ozone, hydrogen peroxide and peracetic acid as per data sheet 202630.  pH value or redox potential as per data sheet 202705.  Liquid level measurements.  Flow rate measurements. e t c . The instrument provides the following calibration options in this function mode: Z e r o p o i n t  Limit value  Zero point and limit value  Cell constant  Temperature coefficient This allows optimum adaptation of the instrument to the sensor. Linear scaling Select this mode when the input signal will be displayed linearly. One of the following units is used for display or control: µ S / c m m S / c m m V p H p p m  Cust. specs. (5 characters)

V3.00/EN/00541528 Page 4/16Data Sheet 202553 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 20255300T10Z002K000 Electrolytic conductivity µS/cm or mS/cm are the units used for display and control. Specific resistance (ultra-pure water) Display/control with the unit kΩ x cm or MΩ x cm. TDS Display/control with the unit ppm. The specific TDS factor can also be entered in this mode. Concentration In this mode, the concentration of a liquid can be determined from its uncompensated conductivity. % or "Cust. specs." are the units used for display and control. Concentration measurement: Cust. specs. with table Non-linear correlations between the input and output variable can be processed in this mode. Typical applications include measuring the level of liquid in horizontal, cylindrical containers or simply measuring the concentration. The input values are processed in a table (max. 20 value pairs). Values can only be entered in the table us ing the optional setup program. The units used for display and control are: µ S / c m m S / c m  Cust. specs. (5 characters)  Use the offset parameter to adjust the display. Calibration Calibration logbook The last five successful calibrations can be accessed from the calibration logbook. This makes it possible to evaluate the aging of the connected sensor. The logbook can be deleted if necessary (useful when changing the sensor). If a datalogger has been fitted (optional board), additional information such as the date and time are documented. Caustic solution N a O H 0t o1 5% b y w t . 0t o9 0° C NaOH 25 to 50 % by wt. 0 to 90 °C Nitric acid HNO 3 0t o2 5% b y w t . 0t o8 0° C HNO3 36 to 82 % by wt. to20 to 80 °C Sulfuric acid H2SO4 0t o2 8% b y w t . 0t o1 0 0° C H2SO4 36 to 85 % by wt. 0 to 115 °C H2SO4 92 to 99 % by wt. 0 to 115 °C Hydrochloric acid Hal 0 to 18 % by wt. 0 to 65 °C Hal 22 to 44 % by wt. -20 to 65 °C Calibration timer The calibration timer indicates (on request) a required routine calibration. The calibration timer is activated by entering the number of days that must expire before there is a scheduled re-calibration (specified by the system or the operator). Additional functions of the JUMO dTRANS AS Min/max value memory This storage records the minimum and maximum input quantities that have occurred. This information can be used, for example, to assess whether the design of the connected sensor is suitable for the values that actually occur. Binary input The following functions can be accessed through the binary input:  Key lock activation When this function is activated, operation is no longer possible via the keypad.  "HOLD" mode activation When this function is activated, the outputs (analog and relay) adopt the states previously defined.  Alarm suppression (controller alarm only) This function is used to temporarily deactivate alarm generation by means of the appropriately configured relay. Bridging the corresponding connection terminals with a floating contact (for example a relay) activates a predefined function. Wash timer A software function ca n be used to trigger cyclically recurring actions by controlling a relay. Control functions Functions can be assigned to the relays. The functions can be configured in turn by parameters P , PI, PD and PID structures can be freely programmed as control functions. Relay outputs Two relay changeover contacts are available for the main measurement variable and/or the temperature. The following functions can be programmed:  Switching direction (min/max)  Limit controller (on-delay/delayed release, hysteresis)  Pulse length output (see control functions)  Pulse frequency output (see control functions)  Modulating function (see control functions)  Pulse functions With this function, the output briefly switches on when the switching point is reached and then switches off again  Wash timer elapsed A l a r m  Sensor/range error  Behavior in the event of an alarm, underrange or overrange measurement, calibration and "HOLD" Datalogger Up to 43,500 data sets can be stored in the datalogger (ring buffer ). Depending on the resolution, that corresponds to a storage time ranging from about 10 hours to 150 days. Data can be read by means of the setup program and then further processed with an "Office" product. The datalogger makes it possible to record and document processes and supports analysis of the same processes. Contact functions Max. limit function Min. limit function Alarm window 1 Hysteresis Setpoint pH On Off Limit Hysteresis Limit pH On Off Setpoint Hysteresis Setpoint pH On Off Limit Distance

V3.00/EN/00541528 Page 5/16Data Sheet 202553 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 20255300T10Z002K000 Pulse contact: Triggering condition shorter than pulse duration Time On Off Pulse duration Pulse contact Time On Off Trigger condition Alarm window 2 Hysteresis Setpoint pH On Off Limit Distance Pulse contact: Triggering condition longer than pulse duration Time On Off Pulse duration Pulse contact Time On Off Trigger condition Pulse width controller (output active with x > w and P control structure) If actual value x exceeds setpoint w, the P controller will control in proportion to the control deviation. When the proportional range is exceeded, the controller operates with an output level of 100 % (100 % clock ratio). Pulse frequency controller (output active with x > w and P control structure) If actual value x exceeds setpoint w, the P controller will control in proportion to the control deviation. When the proportional range is exceeded, the controller operates with an output level of 100 % (maximum switching frequency). Process value X Setpoint W Proportional band XP 100% 50% Output level y Switching period 10% 90% 90% 10% tOn 50%50% tOff 10% 90% XP X - W0 1 100% 50% No pulses 50% of pulse frequency Maximum pulse frequency Setpoint W Proportional band XP XP X - W0 1 Output level y Process value X Math and logic module The math module makes it possible to integrate measurement value of the analog inputs into a mathematical formula so that the calculated process variable can be displayed. The logic module can be used, for example, to link binary inputs an d limit comparators with each other logically. Up to two math or logic formulas can be entered with the option al setup program and the results of calculations can be displayed or exported via outputs (via PC setup software only). Setup PC program (accessory) The setup PC program is available in German, English and French for configuring the instrument. You can use it to create and edit sets of data and tr ansfer them to the instrument, as well as read them out from it. The data can be stored and printed (via PC setup software only). Setup interface The setup interface is integrated into the JUMO dTRANS AS 02 by default. You can use it, together with the setup program (accessory) and a setup interface (accessory), to configure the instrument. RS232/RS485 interface The serial interface is used for communication with higher-level systems when the Modbus/ Jbus protocol is used. PROFIBUS-DP The JUMO dTRANS AS 02 can be integrated into a fieldbus system according to the PROFIBUS-DP standard via the PROFIBUS- DP interface. This PROFIBUS-DP version is specially designed for communication between automation systems and distributed peripheral devices at the field level and is optimized for speed. Data is transferred serially based on the RS485 standard.

V3.00/EN/00541528 Page 6/16Data Sheet 202553 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 20255300T10Z002K000 Technical data Inputs (main board) Resistance thermometer inputs (optional board) Standard signals inputs (optional board) Temperature compensation for conductivity Measuring circuit monitoring Measuring range/control range A ccuracy Effect of temperature Standard signal 0(4) to 20 mA, 0 to 1 V, 0 to 10 V 0.25 % of range 0.2 %/10 K Secondary input Temperature Pt100/1000 -50 to +250 °C a a Selectable in °F. ≤ 0.25 % of range 0.2 %/10 K Temperature NTC/PTC 0.1 to 30 k Ω Entry via table with 20 value pairs ≤ 1.5 % of range 0.2 %/10 K Resistance transmitter Minimum: 100 Ω Maximum: 3 kΩ ±5 Ω 0 . 1% / 1 0K Designation Connection Measuring range Measuring accuracy Effect of ambient temperature3-wire/4-wire 2-wire Pt100 DIN EN 60751 (factory-set) 2-wire/3-wire/ 4-wire -200 to +850 °C ≤ 0.05 % ≤ 0.4 % 50 ppm/K Pt1000 DIN EN 60751 (factory-set) 2-wire/3-wire/ 4-wire -200 to +850 °C ≤ 0.1 % ≤ 0.2 % 50 ppm/K Sensor lead resistance Maximum 30 Ω per line with 3- and 4-wire circuit Measurement current Approx. 250 µA Lead compensation Not required for 3- and 4-wire circuit. With a 2-wire circuit, lead resistance can be compensated in the software by correcting the process value. Designation Measuring range Measuring accuracy Effect of ambient temperature V o l t a g e 0 ( 2 )t o1 0V , 0t o1V Input resistanceE > 100 kΩ ≤ 0.05 % 100 ppm/K Electrical current 0(4) to 20 mA, voltage drop ≤ 1.5 V ≤ 0.05 % 100 ppm/K Resistance transmitter Minimum: 100 Ω Maximum: 4 kΩ ±4 Ω 100 ppm/K Type of compensation Range a a Note the sensor operating temperature range! Linear 0 to 8 %/K -10 to +160 °C ASTM D1125 - 95 (ultra-pure water) 0 to 100 °C Natural waters (ISO 7888) 0 to 36 °C Reference temperature Adjustable from 15 to 30 °C; preset to 25 °C (default) Inputs Underrange/overrange Short circuit Broken lead Temperature Yes Yes Yes Voltage 2 to 10 V 0t o1 0V 0t o1V Yes Yes Yes Yes No No Yes No No Current 4 to 20 mA 0t o2 0m A Yes Yes Yes No Yes No Resistance transmitter No No Yes

V3.00/EN/00541528 Page 7/16Data Sheet 202553 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 20255300T10Z002K000 Binary input Controller Outputs Display Activation Floating co ntact is open: function is not active Floating contact is closed: function is active Function Key lock, manual mode, HOLD , HOLD inverse, alarm suppression, freeze measured value, level lock, reset day counter, reset total counter, parameter set switchover Controller type Limit comparators, limit controllers, pulse length controllers, pulse frequency controllers, modulating controllers, continuous controllers Controller structure P/PI/PD/PID Relay (changeover) PSU board Contaact rating 5 A at AC 240 V resistive load Contact service life 350,000 operations at nominal load/750,000 operations at 1 A Voltage supply for 2-wire transmitter PSU board Electrically isolated, non-controlled DC 17 V at 20 mA, open-circuit voltage approx. DC 25 V Voltage supply for inductive proximity switch Optional board DC 12 V; 10 mA Relay (changeover) Optional board Contaact rating 8A a t A C2 4 0V r e s i s t i v e l o a d Contact service life 100,000 operations at nominal load/350,000 operations at 3 A Relay SPST (normally open) Optional board Contaact rating 3 A at AC 240 V resistive load Contact service life 350,000 operations at nominal load/900,000 operations at 1 A Semiconductor relay Optional board Contact rating 1 A at 240 V Protective circuit Varistor PhotoMOS® relay Optional board U ≤ DC 45 V U ≤ AC 30 V I ≤ 200 mA Voltage Optional board Output signals 0 to 10 V or 2 to 10 V Load resistance R load ≥ 500 Ω Accuracy ≤ 0.5 % Electrical current Optional board Output signals 0 to 20 mA or 4 to 20 mA Load resistance R load ≤ 500 Ω Accuracy ≤ 0.5 % Type LC graphic display, blue with background lighting, 122 × 32 pixels

V3.00/EN/00541528 Page 8/16Data Sheet 202553 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 20255300T10Z002K000 Electrical data Enclosure Interface Approvals/marks of conformity Voltage supply (switch-mode PSU) AC 110 to 240 V +10/-15 %; 48 to 63 Hz or AC/DC 20 to 30 V; 48 to 63 Hz Electrical safety To DIN EN 61010, Part 1 overvoltage category II, pollution degree 2 Power consumption Max. 14 VA (20 A fuse max.) Data backup EEPROM Electrical connection On the back via screw terminals, conductor cross-section up to max. 2.5 mm2 Electromagnetic Compatibility (EMC) DIN EN 61326-1 Interference emission Class A Interference immunity To industrial requirements Enclosure type Plastic encl osure for panel mounting to DIN IEC 61554 (indoor use) Depth behind panel 90 mm Ambient temperature -5 to +55 °C Storage temperature -30 to +70 °C Climatic rating Rel. humidity ≤ 90 % annual mean, no condensation Site altitude Up to 2000 m above sea level Operating position Horizontal Enclosure protection To DIN EN 60529 in panel case Front IP65, rear IP20 in surface-mounted case IP65 Weight (fully fitted) About 380 g Modbus Interface type RS422/RS485 Protocol Modbus, Modbus Integer Baud rate 9600, 19200, 38400 Device address 0 to 255 Max. number of nodes 32 PROFIBUS-DP Device address 0 to 255 Mark of conformity Testing laboratory Certificates/certification numbers Test basis valid for c UL us Underwriters Laboratories E 201387 UL 61010-1 CAN/CSA-C22.2 No. 61010-1 Type 202553/01...

V3.00/EN/00541528 Page 9/16Data Sheet 202553 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 20255300T10Z002K000 Electrical connection Optional board (row 1, slot a, b or c) (1) Row 1 (a) Option 1 (b) Option 2 (c) Option 3 (2) Row 2 Main board (standard signal/resistance/temperature) (3) Row 3 PSU board (volta ge supply/2× relays) Function Symbol Terminal for slot (a) Terminal for slot (b) Terminal for slot (c) Analog input Temperature sensor in a 2-wire circuit Pt100 or Pt1000 Temperature sensor in a 3-wire circuit Pt100 or Pt1000 Resistance transmitter 2 Electrical current 3 Voltage 0(2) to 10 V Voltage 0t o1V Continuous output Current or voltage 2 Modbus interface RS422 --9 RS485 -- 1 1 123 4 1234 5678 678910 9101112

4 L1(L+)5689111213151617 N(L-)

(a)(b)(c) (1) (2) (3) /c74 /c74 E S A RxD- RxD+ TxD- TxD+ RxD/TxD- RxD/TxD+ Mounting information for conductor cross-sections and ferrules Ferrule Conductor cross-section Minimum ferrule length or stripping Minimum Maximum Without ferrule 0.34 mm 2 2.5 mm2 10 mm (stripping) Without collar 0.25 mm 2 2.5 mm2 10 mm With collar up to 1.5 mm2 0.25 mm2 1.5 mm2 10 mm Twin, with collar 0.25 mm 2 1.5 mm2 12 mm

V3.00/EN/00541528 Page 10/16Data Sheet 202553 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 20255300T10Z002K000 Main board (row 2) Function Symbol Terminal for slot (a) Terminal for slot (b) Terminal for slot (c) PROFIBUS-DP interface --9 Datalogger interface RS485 -- 1 0 Relay (1× changeover) K3 1 K4 5 K5 9 Relay (2× NO, common pin) K3 1 K6 3 -K 5 9 K8 11 Triac (1 A) K3 2 K4 6 K5 10 PhotoMOS ® relay (0.2 A) K3 1 K4 5 K5 9 K6 3 K7 7 K8 11 Voltage supply for proximity switch Function Symbol Terminal Standard signal input for electrical current 0(4) to 20 mA Standard signal input for voltage 0(2) to 10 V or 10 to 0(2) V Standard signal input for voltage 0t o1V Temperature sensor in a 2-wire circuit Pt100 or Pt1000 RxD/TxD-P(B) VP(+5V) DGND RxD/TxD-N(A) RxD/TxD- RxD/TxD+ S P O S P S /c74

V3.00/EN/00541528 Page 11/16Data Sheet 202553 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 20255300T10Z002K000 PSU board (row 3) Temperature sensor in a 3-wire circuit Pt100 or Pt1000 Temperature sensor in a 4-wire circuit Pt100 or Pt1000 Resistance transmitter 4 Binary inputs Binary input 1 6+ Binary input 2 7+ Function Symbol Terminal Voltage supply for JUMO dTRANS 02 Voltage supply: AC 110 to 240 V Voltage supply: AC/DC 20 to 30 V

1 L1 (L+)

2 N (L-)

n.c. 4 Voltage supply for external 2-wire transmitter

9 L −

(floating) Relay 2 Switching output K2 (floating) /c74 /c74 E S A S P O S P O

V3.00/EN/00541528 Page 12/16Data Sheet 202553 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 20255300T10Z002K000 Dimensions Panel case Surface-mounted case Close mounting Minimum spacing of panel cutouts Horizontal Vertical Without setup connector 30 mm 11 mm With setup connector (see arrow) 65 mm 11 mm (1) PC interface socket (2) Panel cutout to DIN IEC 61554: 2002-08 (1) Cable gland M16 (2) Cable gland M20 (1) (1) (2) (1) (2)

V3.00/EN/00541528 Page 13/16Data Sheet 202553 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 20255300T10Z002K000 Application examples Indicator/controller for pH (temperature compensation) (2) (1) (3) (4) (1) JUMO dTRANS AS 02 (2) JUMO digiLine pH with analog output type 202705 (3) pH combination electrode (4) Compensation thermometer, type 201085 Indicator/controller for free chlorine, chlorine dioxide, hydrogen peroxide, peracetic acid or ozone (with flow monitoring) (1) (2) (3) (1) JUMO dTRANS AS 02 (2) Measuring cell for free chlorine, type 202630 (3) Flow monitor, type 202811/20

V3.00/EN/00541528 Page 14/16Data Sheet 202553 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 20255300T10Z002K000 Indicator/controller for level or liquid level measurement (1) (2) (1) JUMO dTRANS AS 02 (2) Level measurement probe, type 402090 or type 404391

V3.00/EN/00541528 Page 15/16Data Sheet 202553 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 20255300T10Z002K000 Order details (1) Basic type 202553/01 JUMO dTRANS AS 02 - Transmitter/contro ller for standard signals and temperature in panel case, 96 mm × 48 mm (front IP65) 202553/05 JUMO dTRANS AS 02 - Transmitter/contro ller for standard signals and temperature in surface-mounted case (IP65) (2) Version

8 Standard with factory setting

9 Programming to customer specification

(3) Operating language

01 German

02 English

(4) Optional slot 1 0N o t u s e d 1A n a l o g i n p u t

2 Relay (changeover)

32 R e l a y ( n o r m a l l y o p e n )

52 P h o t o M O S

® relays 6S o l i d s t a t e r e l a y 1 A

7 Voltage supply output DC ±5 V

8 Voltage supply output DC 12 V

(5) Optional slot 2 0N o t u s e d 1A n a l o g i n p u t ® relays 6S o l i d s t a t e r e l a y 1 A (6) Option für Steckplatz 3 0N o t u s e d 1A n a l o g i n p u t ® relays 6S o l i d s t a t e r e l a y 1 A

10 Interface RS422/485

11 Data logger with interface RS422/485

12 PROFIBUS-DP interface

(7) Voltage supply

23 AC 110 to 230 V, +10/-15 %, 48 to 63 Hz

2 5 A C / D C2 0t o3 0V , 4 8t o6 3H z Order example 202553/01 - 8 - 01 - 2 - 2 - 4 - 23

V3.00/EN/00541528 Page 16/16Data Sheet 202553 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 20255300T10Z002K000 Stock version (delivery 3 working days after receipt of order) Accessories (delivery 10 working days after receipt of order) Order code Part no. 202553/01-8-01-4-0-0-23/000 00550842 Item Part no. Holder for C rail (PG 709710) 00375749 Dummy cover 96 mm × 48 mm (PG 709710) 00069680 Pipe mounting set (PG 209791) 00398162 Weather protection roof complete for basic type extension 05 (PG 209791) 00401174 PC setup software (PG 202599) 00560380 PC interface cable including USB/TTL converter and two adapters (USB connecting cable) (PG 709720) 00456352 Optional board Code Part no. Analog input (universal) 1 00442785 Relay (1× changeover) 2 00442786 Relay (2× NO) 3 00442787 Analog output 4 00442788

2 PhotoMOS® relay 5 00566677

Solid state relay 1 A 6 00442790 Supply voltage output DC ±5 V (e.g. for ISFET) 7 00566681 Supply voltage output DC 12 V (e.g. for inductive proximity switch) 8 00566682 Interface RS422/485 10 00442782 Datalogger with RS485 interface 11 00566678 PROFIBUS-DP interface 12 00566679