701580 JUMOUKLTD | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 10

Technical content

Page 1/10Data Sheet 701580 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14

36039 Fulda, Germany

Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex, CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc.

6724 Joy Road

East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 70158000T10Z001K000 JUMO miroVIEW Smart digital indicator with limit value monitoring function Brief description The smart digital indicator is used for the electronic display of various process variables. The pro- cess variables are acquired by t he device via RTD temperature p robe, thermocouple, current 0(4) to 20 mA or voltage 0 to 10 V. Further functionalities are limit value monitoring, min/max val- ue storage, hold function and tare function. The device is avai lable with 2 relays or with 1 relay and 1 digital output (DC 0/14 V). The device is characterized by simple, clearly structured operation supported by texts in English, German, French, and Spanish. Process values, texts, and parameters are shown in two 18-seg- ment LCD displays. Additional display elements inform about the switch positions of the outputs, timer status, and temperature unit. Terminal blocks with PUSH IN technology enable fast electrical installation. Operation, parameterization, and configuration are carried out via a membrane keyboard with four keys. The setup program on a PC allows the device to be configured without any problems. No separate voltage supply is required when configuring via the USB interface (USB-powered). miroVIEW Type 701580 Block diagram Thermocouples Fe-CuNi "L", Fe-CuNi "J" , NiCr-Ni "K" 1 relay (changeover AC 250 V, 10 A) 1 digital output DC 0/14 V or Membrane keypad or Digital input for potential-free contact (not with 3-wire circuit) Digital input Type 701580 2-wire RTD temperature probe Pt100, Pt1000 - AC 230 V +10/-15 %, 48 to 63 Hz - AC 115 V +10/-15 %, 48 to 63 Hz - DC 12 to 24 V 15 %± Voltage supply USB device Analog input Setup interface 3-wire RTD temperature probe Pt100, Pt1000 0(4) to 20 mA 0 to 10 V or or or LCD display 1 relay (changeover AC 250 V, 10 A) 1 relay (NO contact AC 250 V, 5 A) Digital outputs Special features

  • Integrated timer function
  • Service and operating hours counter
  • Fast wiring through PUSH IN technology
  • High-quality display and intuitive opera- tion
  • Configuration on the device or with the setup program (accessories) via USB in- terface (USB-powered
  • Operator guidance with text support in 4 languages
  • Limit value monitoring function Approvals and approval marks (see technical data)

Page 2/10Data Sheet 701580 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex, CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 70158000T10Z001K000

Description

In addition to the classic display of the mea- sured value, the device has additional func- tions such as min/max value display, a hold function for freezing the measured value and a tare function for weighing applications. Some functions can be configured via the membrane keypad on the front. Inputs and outputs RTD temperature probe, thermocouple, cur- rent, voltage can be selected as analog input. A combination of 1 changeover contact and 1 normally open contact or 1 relay output in combination with a digital input is available as relay outputs. The digital input is provided to connect a potential-free contact. USB device interface The device is equipped with a USB device in- terface (micro-B socket on the rear side). This is intended for connecting to a PC and for con- figuring the device via the setup program. Thereby the device is powered via the USB in- terface. As a result, no mains supply is re- quired during the configuration. Electrical connection The electrical connection saves time by using practical spring-cage terminals (Push-In tech- nology). Limit value monitoring functions The device is equipped with three limit value monitoring functions, each with two configu- rable alarm functions. Any analog signal from a selector is selected as the value to be moni- tored. An absolute value serves as the limit value. Special functi ons such as switch-on/ switch-off delay, pulse function, alarm sup- pression in the switch-on phase or in case of a parameter change, alarm latch, and lock with acknowledgment are available. With the limit value monitoring function, extensive alarm and limit value functions can be implemented. Timer After the timer is started, a signal is output for the duration of the timer running time; this sig- nal is invertible. It is also possible to start the timer after the lead time has elapsed or after reaching a tolerance limit. A timer end signal can be output after the timer has elapsed (limit by time or acknowledgement). Service counter The service counter is used either to count the switching frequency of a binary signal or to de- termine its switch-on duration. When the set limit value is reached, a binary signal is acti- vated that needs to be acknowledged. In addition, an operating hours counter is available that deter mines the device's opera- tion time. Setup program The setup program, which is available as an accessory, provides the user with an easy and comfortable way to configure the device using a PC. This allows data records to be created, edited and transferred to the device, as well as read out from there. A recording function for start-up is available. Customer-specific Linearization Sensor signals with special characteristic line properties can also be used through custom- er-specific linearization. Programming is car- ried out in the setup program on the basis of a value table with up to 40 value pairs or through a formula (4th order polynomial).

Page 3/10Data Sheet 701580 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex, CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 70158000T10Z001K000 Technical data Analog input Thermocouples RTD temperature probe Voltage, current (standard signals) Measuring circuit monitoring The device behavior in the event of a malfunction is configurable. Designation Type Standard ITS Measuring range Accuracy a a Accuracy refers to the measuring range. Fe-CuNi "L" DIN 43710 (1985-12) IPTS-68 -200 to +900 °C ≤ 0.4 % Fe-CuNi "J" DIN EN 60584-1:2013 IEC 60584-1:2013 ITS-90 -210 to +1200 °C ≤ 0.4 % from -100 °C NiCr-Ni "K" DIN EN 60584-1:2013 IEC 60584-1:2013 ITS-90 -270 to +1300 °C ≤ 0.4 % from -80 °C Ambient temperature influence ≤ 300 ppm/K Cold junction Internal or external (constant) Cold junction temperature 0 °C (permanently set) Input filter Digital filter, 2nd order; filter constant can be set from 0 to 100.0 s Designation Standard ITS Connection type Measuring range Accuracy a Measuring current Pt100 DIN EN 60751:2008 IEC 60751:2008 ITS-90 Two/three-wire -200 to +600 °C ≤ 0.25 % 500 μA Pt1000 DIN EN 60751:2009 IEC 60751:2008 ITS-90 Two/three-wire -200 to +600 °C ≤ 0.25 % 100 μA Customer-specific 150 to 3000 Ω≤ 0.25 % < 500 μA a Accuracy refers to the measuring range. Ambient temperature influence ≤ 300 ppm/K Sensor line resistance Max. 30 Ω per line Input filter Digital filter, 2nd order; filter constant can be set from 0 to 100.0 s Designation Measuring range Accuracy a Input resistance or compli- ance voltage V o l t a g e 0t o1 0V ≤ 0.15 % > 100 kΩ C u r r e n t 4t o2 0m A ≤ 0.125 % < 2.5 V 0t o2 0m A ≤ 0.125 % < 2.5 V a Accuracy refers to the maximum measuring range. Small measuring spans lead to reduced linearization accuracy. Ambient temperature influence ≤ 100 ppm/K Deviation below/above the measuring range According to NAMUR recommendation NE 43 (only current input 4 to 20m A ) Input filter Digital filter, 2nd order; filter constant can be set from 0 to 100.0 s Measuring probe Measuring range un- derflow Measuring range overflow Short-circuit (probe/ line) Break (probe/line) Reverse polarity RTD temperature probe ++ ++ ++ ++ --- Thermocouple ++ ++ --- ++ (+) a Current 0 to 20 mA --- ++ --- --- ---

Page 4/10Data Sheet 701580 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex, CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 70158000T10Z001K000 Digital input Digital outputs Interface Display Current 4 to 20 mA ++ ++ ++ ++ ++ Voltage 0 to 10 V --- ++ --- --- ++ ++ = is detected --- = is not det ected (+) = is detected in certa in conditions a Dependent on the set characteristic line Measuring probe Measuring range un- derflow Measuring range overflow Short-circuit (probe/ line) Break (probe/line) Reverse polarity Input for potential-free contact Function Contact closed: input is active (R ON < 1 kΩ) Contact open: input is inactive (ROFF > 100 kΩ) 1 relay (changeover contact) Order code 23 Switching capacity Max. 10 A at DC 30 V or AC 250 V, resistive l oad Contact life 100,000 switching operations at rated load 1 relay (normally open contact) Switching capacity Max. 5 A at DC 30 V or AC 250 V, resistive lo ad Contact life 100,000 switching operations at rated load 1 relay (normally open contact) Order code 26 Switching capacity Max. 10 A at DC 30 V or AC 250 V, resistive l oad Contact life 100,000 switching operations at rated load 1 digital output DC 0/14 V Output signal DC 0/14 V ±15 % Current Max. 20 mA (at nominal voltage 14 V) USB device Connector type Micro-B (socket) Standard Low-Speed, Full-Speed Max. cable length 5 m 18-segment LCD displays Upper display: Lower display: Digit height 13 mm 4 mm Color white Green Places, including decimal places 4 7 Decimal places 0, 1, or automatic (configurable)

Page 5/10Data Sheet 701580 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex, CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 70158000T10Z001K000 Electrical data Environmental influences Voltage supply according to the ordered version

02 AC 230 V -15/+10 %, 48 to 63 Hz

05 AC 115 V -15/+10 %, 48 to 63 Hz

30 DC 12 to 24 V, -15/+15 % SELV

Electrical safety acc. to DIN EN 61010, part 1 Overvoltage category II to 300 V mains voltage, Pollution degree 2 Power consumption Type AC 230 V: Type AC 115 V: Type DC 12 to 24 V: Accuracy of timer 1 % Sampling rate 250 ms Electrical connection On the back v ia spring-cage terminals (PUSH IN technology) Conductor cross section, mechanical Wire or stranded wire (without ferrule) Min. 0.2 mm2, max. 1.5 mm2 Stranded wire with ferrule Without plastic collar: min. 0.2 mm 2, max. 1.5 mm2 With plastic collar: min. 0.2 mm2, max. 0.75 mm2 Stripping length 8 mm Conductor cross section, electric 5 A load current Min. 0.75 mm 2 10 A load current Min. 1.0 mm 2 16 A load current Min. 1.5 mm 2 Ambient temperature range Storage -30 to +70 °C Operation -10 to +55 °C Site altitude Max. 2000 m above sea level Climatic environmental influences According to DIN EN 60721-3 with extended temperature range Resistance to climatic conditions ≤ 90 % rel. humidity without condensation Storage According to class 1K2 Operation According to class 3K3 Mechanical environmental influences According to DIN EN 60721-3 Storage According to class 1M2 Transport According to class 2M2 Operation According to class 3M3 Electromagnetic compatibility (EMC) Product family standard DIN E N 61326-1 Interference emission Class B a a The product is suitable for industrial use as well as for households and small businesses Interference immunity Industrial requirement

Page 6/10Data Sheet 701580 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex, CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 70158000T10Z001K000 Case Approvals and approval marks The device is approved if the relevant approval mark is pictured on the device. Dimensions Type 701580 Case type Plastic case for panel mounting according to IEC 61554 (indoor use), cobalt blue RAL 5013 Case front Membrane keyboard, upper slope cobalt blue RAL 5013, lower slope silver grey RAL 7001 Panel thickness 1 to 10 mm Case mounting In panel using the supplied mounting frame or both mounting elements Operating position Any a a The maximum admissible ambient temperature only applies for the installation with the display in a vertical position. Protection type According to DIN EN 60529, IP65 on the front, IP20 on the back Weight Type 701580 Max. 154 g Approval mark Test facility Certificates/Certification numbers Inspection basis Valid for c UL us Underwriters Laboratories E201387 UL 61010-1 (3rd Ed.), CAN/CSA-22.2 No. 61010-1 (3rd Ed.) All types 4,8 68,5 73 7660 28 34,5 36

Page 7/10Data Sheet 701580 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex, CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 70158000T10Z001K000 Panel cut-outs Panel cut-outs according to DIN IEC 61554 Galvanic isolation Type Panel cut-out (width x height) Mounting depth with- out seal Minimum spacing of panel cut-outs (for close mounting) With terminal blocks Horizontal Vertical 701580 69 +1 mm × 28.5 +1 mm 62 mm 15 mm 30 mm (a) (1) AC 3000 V (b) (a) AC 3000 V (4) (5) (6) (7) (9) (3) (10) (a) (2) AC 3000 V (8) (a) AC 3000 V a The voltage specifications correspond to the test voltag- es (alternating voltage, rms values) according to DIN EN 61010-1 (VDE 0411-1):2020-03 b Functional galvanic isolation for connecting SELV or PELV electrical circuits

1 Type 701580 (order code 23):

2 relay outputs (changeover contact, normally open con- tact) The two relay outputs are not allowed to be operated on different mains voltage circuits. It is also not admissible to mix how the relay outputs are operated – using a SELV electrical circuit and a mains supply circuit. 2 Type 701580: Not available.

3 Type 701580 (order code 26):

1 relay output (normally open contact)

4 Type 701580 (order code 26):

1 digital output DC 0/14 V 5 or 6 Voltage supply DC 12 V to 24 V

7 Voltage supply 230 V, 48 to 63 Hz

1 1 5V , 4 8t o6 3H z

8 USB interface

9 Digital input 10 Analog input

Page 8/10Data Sheet 701580 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex, CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 70158000T10Z001K000 Display and control elements (1) (2) (7)(5) (8)(3)(4)(6) 1 Display 1 - 18-segment LCD display (e.g. analog in- put), 4-digit, white; also for displaying menu items, parameters and text 2 Display 2 - 18-segment LCD display (e.g. text), 7-digit green; displaying of menu items, parameters, text and values; here individually configured measuring point designa- tion (ZONE 1)

3 Timer (illuminated = on , flashing = started),

4 Switch position of the digital outputs (yellow = active)

5 Up (in the menu: increase value, select previous menu

item or parameter)

6 Down (in the menu: reduce value, select next menu

item or parameter)

7 Back (in menu: back to previous menu level, exit editing

mode without change; in basic status: configurable function)

8 Menu/OK (call up main menu, switch to submenu/level,

switch to editing mode, exit editing mode with change)

Page 9/10Data Sheet 701580 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex, CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 70158000T10Z001K000 Connection diagram The connection diagram in the data sheet provides information on product selection. For the electrical connection, only use the installation instructions or the operating manual. Type 701580 Terminal strip 2: Analog input, digital input Terminal strip 3: L1(L+), N(L-) Terminal strip 4: Digital outputs RTD temperature probe in three-wire circuit (no digi- tal input) Voltage supply (see name- plate) A C 2 3 0V , 4 8t o6 3H z or AC 115 V, 48 to 63 Hz or DC 12 to 24 V 1 relay changeover contact, 1 relay normally open contact Digital output 1 (changeover contact) and digital output 2 (normally open contact): RTD temperature probe in two-wire circuit and Digital input Thermocouple and digital input The two relays are not allowed to be operated on dif- ferent mains voltage circuits. It is also not admissible to mix how the relays are operated – using a SELV electrical circuit and a mains supply circuit. Current 0(4) to 20 mA and digital input 1 relay normally open contact, 1 digital output DC 0/14 V Digital output 1 (normally open contact) and digital output 2 (DC 0/14 V): Voltage 0 to 10 V and digital input 1 2 3 1 2 3 4 5 1 2 1 2 3 1 2 3 1 2 3 Ix 2 3 4 5 DC 0/14V 1 2 1 2 3 Ux

Page 10/10Data Sheet 701580 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 Email: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex, CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 62 50 29 Email: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: +1 315 437 5866 Fax: +1 315 437 5860 Email: info.us@jumo.net Internet: www.jumousa.com 70158000T10Z001K000 Order details Scope of delivery Accessories (1) Basic type 701580 Type 701580 with max. 2 relays, format (76 x 36 x 62) mm (2) Version

0 Standard version

1 Customized hardware

2 Customized software

3 Customized hardware and software

(3) Input (measurement input groups) a a It is not possible to switch from one measurement input group to another 01 1 RTD temperature probe Pt100 , Pt1000 in two-wire circuit, 1 digital input 02 1 RTD temperature probe Pt100, Pt1000 in three-wire circuit 04 1 thermocouple and 1 digital input 05 0(4) to 20 mA and 1 digital input (4) Output 23 1 relay (changeover contact AC 250 V, 10 A) and 1 relay (normal ly open contact AC 250 V, 5 A), resistive load 26 1 relay (normally open contact AC 250 V, 10 A) resistive load a nd 1 digital output DC 0/14 V b b Minimum order quantity 50 pieces (5) Voltage supply

02 AC 230 V, +10/-15 %, 48 to 63 Hz

05 AC 115 V, +10/-15 %, 48 to 63 Hz c

c Minimum order quantity 50 pieces

30 DC 12 to 24 V +15/-15 %

(6) Extra codes

000 None

Order example 701580 / 0 - 01 - 23 - 02 / 000 1 device in the ordered version 1 quick start guide 1 mounting frame Description Part no. Setup program 00777355 USB cable, A connector to Micro-B connector, length 3 m 00616250