V9.00/EN/00485235/2025-10-27 Page 1/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 JUMO heatTHERM-AT/-DR with single-pole snap switch Special features
- -connection technology - reduced installation time by 50 %
- Stable switching point position due to am bient temperature compensation (standard)
- Max. switching capacity 16 A, 230 V
- Tested according to DIN EN 14597
- Operating life at least 250,000 switching cycles for TR and TW
- Switching point deviation during the entire operating life of up to ±5 %
- Protection type max. IP54
- UL approval (extra code 061)
Description
High application flexibility and the latest connection technology are the essential equipment fea- tures of this new thermostat series. The thermostat case is suitable for all common installation types such as wall mounting, immer- sion sleeve, and contact fastening. It can be used universally and reduces the variant range be- cause different mounting types must no longer be taken into account. The JUMO heatTHERM-DR (type 7 + 8) type is a specific variation with a special housing bottom section for DIN rail or wall mounting. As a result, easy mounting on mounting rails TH35 accord- ing to DIN EN 60715 (e.g. in control cabinets) is possible. This variant considerably reduces the mounting time. The flue gas automatic reset temperature limiter JUMO heatTHERM-AT locks the gas/oil vessel that is connected in parallel with the wood vessel to a chimney. For these international innovative surface-mounted thermostats with PUSH IN terminal technol- ogy, the connection wires are only inserted into the terminal point up to the stop - that's it! No tool is required for connecting the wire or strand with a ferrule and the wiring becomes safer. In this manner, the costs and time required for connecti on are considerably reduced compared to the conventional screw terminal. The PUSH IN terminal technology allows direct switching of loads up to 16 A at AC 230 V. The installation costs can be reduced further because a load contactor is no longer required. Available are temperature controllers (TR), temperature monitors (TW), safety temperature mon- itors (STW), safety temperature limiters (STB) as single or double thermostats, and flue gas tem- perature monitors (ATW). Approvals according to DIN EN 14597, DGRL, and UL indicate the high quality standards for this product series. Type 603070/0170 (TR/STB) Type 603070/0001 (TR) Type 603070/0002 (TW) Type 603070/0002 (TW)
V9.00/EN/00485235/2025-10-27 Page 2/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Approval marks and certificates Designation DIN Testing agency DIN CERTCO Certificates/certification numbers TR1191 Inspection basis DIN EN 14597 Valid for Type 603070/0001 (TR), Type 603070/0120 (TR), Type 603070/0170 (TR) Designation DIN Testing agency DIN CERTCO Certificates/certification numbers TW1192 Inspection basis DIN EN 14597 Valid for Type 603070/0002 (TW), Type 603070/0202 (TW) Designation DIN Testing agency DIN CERTCO Certificates/certification numbers STW(STB)1193 Inspection basis DIN EN 14597 Valid for Type 603070/0020 (STW), Type 603070/0070 (STB), Type 603070/0120 (STW), Type 603070/0170 (STB) Designation DIN Testing agency DIN CERTCO Certificates/certification numbers STB1194 Inspection basis DIN EN 14597 Valid for Type 603070/0070 (ATW) Designation DIN Testing agency DIN CERTCO Certificates/certification numbers ATW1218 Inspection basis DIN EN ISO 13849-1 Valid for Type 603070/0020 (ATW) Designation B10d Testing agency TÜV SÜD Certificates/certification numbers C-T 1355-03/11 a a For further details see Safety manual JUMO heatTHERM (-AT), (-DR) 602031, 603070. Switching capacity check implemented at 16 A, 230 V, ohmic load. Inspection basis DIN EN 14597, DIN EN ISO 13849-1, draft DIN EN 13611 A2 Designation UL Testing agency UL Certificates/certification numbers E66358 Inspection basis UL 873, C22.2 No. 24-1993 Designation PED Testing agency TÜV Süd Certificates/certification numbers Z-IS-TAF-MUC-18-05-2652099-02162623 Inspection basis 2014/68/EU, DIN EN 14597 Valid for Type 603070/0020 (STW), Type 603070/0070 (STB), Type 603070/0120 (STW), Type 603070/0170 (STB) Designation UKCA Testing agency TÜV Süd BABT Certificates/certification numbers C-IS-TAF-MUC-23-01-2652099-23132407 Inspection basis 2014/68/EU, DIN EN 14597 PED Pressure Equipment Directive
V9.00/EN/00485235/2025-10-27 Page 3/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Technical data Switching functions Temperature compensation Temperature controller TR/ temperature monitor TW If the temperature on the temperature probe exceeds the setpoint value, the microswitch is activat- ed by the transmission mechanics and the electrical circuit is opened or closed.If the temperature falls below the selected setpoint value (by the amount of the switching differential), the microswitch is reset to its initial position. Safety temperature monitor STW If the temperature on the temperature probe exceeds the setpoint value, the snap-action switch is activated and the electrical circuit is opened or closed. If the temperature falls below the selected setpoint value (by the amount of the switching differential), the snap-action switch is reset to its initial position. The electrical circuit 1 - 2 opens when the probe of STW (STB) and STB cools down to the nega- tive temperature range, but it closes again automatically if the temperature rises. If the measuring system is destroyed (i.e. if the expansion fluid emerges) the pressure in the dia- phragm drops and permanently opens the electrical circuit. Safety temperature limiter STB If the temperature on the temperature probe exceeds the switching point, the snap-action switch is activated, the electrical circuit is opened or closed, and the snap-action switch is mechanically locked.The unlocking difference depends on the control range. Exact values are available from the respective types. They are also available upon request. If the temperature falls below the selected setpoint value (by the amount of the unlocking difference) then the snap-action switch can be man- ually unlocked again. The electrical circuit 1 - 2 opens when the probe of STW (STB) and STB cools down to the nega- tive temperature range, but it closes again automatically if the temperature rises. If the measuring system is destroyed (i.e. if the expansion fluid emerges) the pressure in the dia- phragm drops and permanently opens the electrical circuit. Unlocking is no longer possible. When the ambient temperature on the switching head and the capillary deviates (from the calibration ambient temperature of 22 °C) a switching point offset occurs. This switching point offset is reduced to a minimum due to the temperature compensation.
V9.00/EN/00485235/2025-10-27 Page 4/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Housing Electrical data Type 5 + 6 Type 7 + 8 Case bottom section PA (reinforced) Color Silver-gray RAL 7001 (for TZ 061 black) Case lid ABS with inspection glass (PMMA) – Color Cobalt-blue RAL 5013 (for TZ 061 light-gray, RAL 7035) Setpoint adjustment TR Switching point can be adjusted externally with the rotary knob. TW, STW, STB, ATW Switching point can be adjusted with a screw- driver once the case lid has been removed. The set switching point can be checked through the inspection glass. Switching point can adjusted with a screwdriver. Protection type EN 60529 EN 60529 IP40 or IP54 (for extra code 402) IP20 Cable inlet Cable gland M20 x 1.5, for cable-∅ 6-12 mm Cable connection directly on terminals Capillary Ø 1.25 mm Min. bending radius 5m m Material Copper (Cu) or stainless steel (CrNi, 1.4301) Case fastening Pipe mounting with clamping belt for pipe diam- eter 15 to 100 mm, thermowell mounting, wall mounting Wall mounting, DIN rail installation TH35 ac- cording to DIN EN 60715 Weight Approx. 0.2 kg Electric contact Snap-action switch with single-pole changeover contact Switching capacity TR/TW/STW/ATW STB On the N/C contact (contact deck 1 - 2): DC 230 V +10 %, 0.25 A On the N/C contact (contact deck 1 - 2): DC 230 V +10 %, 0.25 A On the N/O contact (contact deck 1 - 4): DC 230 V +10 %, 0.25 A On the signal contact (contact deck 1 - 4): DC 230 V +10 %, 0.25 A Electrical connection contact (plug-type terminal) Connection cross section 0.75 to 2.5 mm 2 fine wired (single-wire, fine wired with ferrule) Switching reliability To ensure the greatest possible switching reliability, we recommend a minimum load of: AC/DC = 24 V, 100 mA for silver contacts AC/DC = 10 V, 5 mA for gold-plated contacts (extra code 702)
V9.00/EN/00485235/2025-10-27 Page 5/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Operating data Connection diagram Switching point accuracy TR, TW STW, STB with a setting range of: 20 to 80 °C 70 to 130 °C Switching differ- ential 2.5 % In the "first half" (20 to 50 °C) In the "second half" (50 to 80 °C) In the "first half" (70 to 100 °C) In the "second half" (100 to 130 °C) In the upper third of the scale ±3 %, at scale beginning ±6 % Temperature compensation When the ambient temperature on the switching head and the capillary deviates (from the calibra- tion ambient temperature of 22 °C) a switching point offset of approx. -0.1 K/K occurs (switching point change referring to the ambient temperature change, measured at limit value 120 °C permanently set and capillary length 2,000 mm). This switching point offset is reduced to a minimum due to the standard temperature compensa- tion. Limit value temperatures Transport and storage -30 to +80 °C In use 0 to 80 °C With UL approval Max. 65 °C Design type 7 Max. 55 °C Design type 6+ 8 Max. 50 °C Pipe mounting Pipe temperature Max. 120 °C Rated position (NL) According to DIN 16257, NL 0 to NL 90 (different NL upon request) TR, TW, STW STB
V9.00/EN/00485235/2025-10-27 Page 6/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Devices in stock: JUMO heatTHERM-AT Temperature controller TR, design type 5 Type 603070/0001a a Further design versions (control range, switching differential, process connection) upon request. Minimum order quantity 100 pieces.
- Protection type IP54
- Compensation of the ambient temperature
- Individual limitation of the control range Part no. Type Control range Capillary Probe-Ø (d) × L Switching differential Process connection °C mm mm
60003185 JUMO
0 to 120 2,000 6 × 87 Approx. 3 K With internal capillary and contact probe
60003186 Thermowell: brass nickel-plated
PP
V9.00/EN/00485235/2025-10-27 Page 7/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Temperature monitor TW Type 603070/0002a a Further design versions (control range, switching differential, process connection) upon request. Minimum order quantity 100 pieces.
- Protection type IP54
- Compensation of the ambient temperature
- Switching value check through inspection window in the case lid
- UL approval (extra code 061) Part no. Type Control range Capillary Probe-Ø (d) × L Switching differential Process connection °C mm mm
60003187 JUMO
0 to 120 2,000 6 × 87 Approx. 3 K With internal capillary and contact probe 60003441 b b UL approval (extra code 061).
60003188 Thermowell: brass nickel-plated
60003440b 0 to 200 6 × 78 Approx. 5 K With internal capillary and contact probe PP
V9.00/EN/00485235/2025-10-27 Page 8/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Safety temperature monitor STW, design type 5 Safety temperature limiter STB, design type 5 Type 603070/0020a a Further design versions (control range, switching differential, process connection) upon request. Minimum order quantity 100 pieces.
- Protection type IP54
- Compensation of the ambient temperature
- Switching value check through inspection window in the case lid
- Capillary break protection Part no. Type Control range Capillary Probe-Ø (d) × L Switching differential Process connection °C mm mm
60003229 JUMO
20 to 80 2,000 6 × 66 Approx. 10 K With internal capillary and contact probe 60003189 70 to 130 6 × 66 Thermowell: brass nickel-plated Type 603070/0070 a a Further design versions (control range, switching differential, process connection) upon request. Minimum order quantity 100 pieces.
- Protection type IP54
- Compensation of the ambient temperature
- Switching value check through inspection window in the case lid
- External acknowledgment of the switching point is possi- ble
- Capillary break protection
- UL approval (extra code 061) Part no. Type Control range Capillary Probe-Ø (d) × L Unlocking difference Process connection °C mm mm
60003230 JUMO
70 to 130 2,000 6 × 66 Approx. 10 K With internal capillary and contact probe
60003190 Thermowell: brass nickel-plated
b b UL approval (extra code 061). 50 to 300 6 × 85 Approx. 25 K With internal capillary and contact probe 60003443b 20 to 150 6 × 66 Approx. 15 K
V9.00/EN/00485235/2025-10-27 Page 9/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Room thermostat temperature controller TR, design type 6 Room thermostat temperature limiter TW, design type 6 Type 603070/0001a a Further design versions (control range, switching differential, process connection) upon request. Minimum order quantity 100 pieces.
- Protection type IP54
- Wall mounting
- Individual limitation of the control range Part no. Type Control range Capillary Probe-Ø (d) × L Switching differential Process connection °C mm mm
60003191 JUMO
-10 to +40 – – 1.5 - 2 K Spiral probe 60003192 0 to 50 Type 603070/0002 a a Further design versions (control range, switching differential, process connection) upon request. Minimum order quantity 100 pieces.
- Protection type IP54
- Wall mounting
- Switching value check through inspection window in the case lid Part no. Typ e Control range Capillary Probe-Ø (d) × L Switching differential Process connection °C mm mm
60003193 JUMO
-10 to +40 – – 1.5 - 2 K Spiral probe 60003194 0 to 50
V9.00/EN/00485235/2025-10-27 Page 10/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Temperature controller/safety temperature monitor TR/STW, design type 5 Typ 603070/0120a a Further design versions (control range, switching differential, process connection) upon request. Minimum order quantity 100 pieces.
- Protection type IP54
- Compensation of the ambient temperature
- Switching value check through inspection window in the case lid
- Capillary break protection for STW Part no. Type Control range Capillary Probe-Ø (d) × L Switching dif- ferential Process connection °C mm mm
60003195 JUMO
TR: 0 to 120 2,000 6 × 87 Approx. 3 K With internal capillary and contact probe STW: 70 to 130 6 × 66 Approx. 10 K 60003231 TR: 0 to 120 6 × 87 Approx. 3 K Thermowell: brass nickel-plated STW: 70 to 130 6 × 66 Approx. 10 K
V9.00/EN/00485235/2025-10-27 Page 11/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Temperature controller/safety temperature limiter TR/STB, design type 5 Type 603070/0170a a Further design versions (control range, switching differential, process connection) upon request. Minimum order quantity 100 pieces.
- Protection type IP54
- Compensation of the ambient temperature
- Switching value check through inspection window in the case lid
- Capillary break protection for STW Part no. Type Control range Capillary Probe-Ø (d) × L Switching differential/ unlocking difference Process connection °C mm mm
60003196 JUMO
TR: 0 to 120 2,000 6 × 87 Approx. 3 K With internal capillary and con- tact probeSTW: 70 to 130 6 × 66 Approx. 10 K 60003232 TR: 0 to 120 6 × 87 Approx. 3 K Thermowell: brass nickel-plated STW: 70 to 130 6 × 66 Approx. 10 K
V9.00/EN/00485235/2025-10-27 Page 12/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Room thermostat temperature monitor/temperature monitor TW/TW, design type 6 Type 603070/0202a a Further design versions (control range, switching differential, process connection) upon request. Minimum order quantity 100 pieces.
- Protection type IP54
- Wall mounting
- Switching value check through inspection window in the case lid Part no. Typ e Control range Capillary Probe-Ø (d) × L Switching differential Process connection °C mm mm
60003212 JUMO
-10 to +40 – – 1.5 - 2 K Spiral probe 60003213 0 to 50
V9.00/EN/00485235/2025-10-27 Page 13/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Flue gas temperature monitor with mounting sleeve, design type 5 Type 603070/0020a a Further design versions (control range, switching differential, process connection) upon request. Minimum order quantity 100 pieces.
- Switching value check through inspection window in the case lid
- Max. allowable probe tem- perature 600 °C
- Approval as ATW with capil- lary break protection accord- ing to DIN EN 14597
- Time constant t 0.632 ≤ 45 sec. in flue gas Part no. Typ e Control range Capillary Probe-Ø (d) × L Switching differential Process connection °C mm mm
60003390 JUMO
20 to 280 – 6 × 150 Approx. 1.5 K Intermediate piece with mounting flange
V9.00/EN/00485235/2025-10-27 Page 14/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Devices in stock: JUMO heatTHERM-DR Thermostat for DIN rail installation TH35, according to DIN EN 60715, design type 7 Type 603070/....-a a Further design versions (control range, switching differential, process connection) upon request. Minimum order quantity 100 pieces.
- Protection type IP20
- DIN rail installation TH35
- Easy to assemble and user friendly Part no. Type Control range Capillary Probe-Ø (d) × L Switching differential Process connection °C mm mm Temperature monitor TW 60003283 603070/0002 0 to 120 2,000 6 × 87 Approx. 3 K With capillary and contact probe 60003284 0 to 200 6 × 78 Approx. 5 K 60003285 50 to 300 6 × 66 Approx. 6 K Safety temperature monitor STW 60003286 603070/0020 70 to 130 2,000 6 × 66 Approx. 10 K With capillary and contact probe Safety temperature limiter STB Unlocking difference 60003287 603070/0070 70 to 130 2,000 6 × 66 Approx. 10 K With capillary and contact probe 60003299 20 to 150 6 × 60 In the upper third approx.
15 K, at the scale begin-
ning approx. 30 K 60003300 50 to 300 6 × 87 In the upper third approx.
25 K, at the scale begin-
ning approx. 45 K a a
V9.00/EN/00485235/2025-10-27 Page 15/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Thermostat for DIN rail installation TH35, according to DIN EN 60715, design type 8 Type 603070/0002-8a a Upon request. Minimum order quantity 100 pieces.
- Protection type IP20
- DIN rail installation TH35
- Easy to assemble and user friendly 1 Fastening hole = Ø 4.5 mm a a a a a
V9.00/EN/00485235/2025-10-27 Page 16/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Order details (1) Basic type
603070 JUMO heatTHERM-AT/-DR
(2) Basic type extensions
0001 Temperature controller (TR)
0002 Temperature monitor (TW)
0020 Safety temperature monitor (STW) or flue gas temperature monitor (ATW)
0070 Safety temperature limiter (STB)
0120 Temperature controller/Safety temperature monitor (TR/STW)
0170 Temperature controller/Safety temperature limiter (TR/STB)
0202 Temperature monitor/Temperature monitor (TW/TW)
(3) Design type
5 Surface-mounted thermostat with thermowell, flange sleeve, capillary, or as surface probe
6 Bimetal room thermostat with coil sensor
7 DIN rail thermostat with remote sensor
8 DIN rail room thermostat with coil sensor
(4) Control range 1 a
000 With permanently set limit value
016 -10 to +40 °C TR, TW 021 0 to 50 °C TR, TW 026 0 to 120 °C TR, TW 028 0 to 200 °C TR, TW 040 20 to 80 °C STW 043 20 to 150 °C TR, TW, STB 064 50 to 300 °C TR, TW, STB with protec tive sleeve (process connection 76) 671 70 to 130 °C STW, STB 384 20 to 280 °C ATW (only with process connection 80) (5) Control range 2 a
000 Single thermostat
016 -10 to +40 °C TR, TW (adjustable) 021 0 to 50 °C TR, TW (adjustable) 671 70 to 130 °C STW, STB (adjustable) (6) Limit value 1 095 95 °C 100 100 °C 110 110 °C (7) Limit value 2
000 With adjustable control range
095 95 °C 100 100 °C 110 110 °C (8) Switching differential 1
00 Without switching differential (STB)
25 2.5 % of the scale range 70 7 % (9) Switching differential 2 25 2.5 % of the scale range 70 7 % (10) Capillary length 1 b
V9.00/EN/00485235/2025-10-27 Page 17/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000
0 Only for room thermostat
1000 1,000 mm 2000 2,000 mm 3000 3,000 mm 4000 4,000 mm 5000 5,000 mm (11) Capillary length 2b 1000 1,000 mm 2000 2,000 mm 3000 3,000 mm 4000 4,000 mm 5000 5,000 mm (12) Material of capillary 1
00 None
20 CrNi (Stainless steel)
40 Cu (Copper)
(13) Material of capillary 2 (14) Process connection
10 Plain cylindrical probe/surface probe
15 Spiral probe
80d Intermediate piece with mounting flange (15) Probe diameter 1 6Ø 6 m m 17 Ø 17 mm e (16) Probe diameter 2
00 Single thermostat
6Ø 6 m m 17 Ø 17 mme (17) Probe material 1 (18) Probe material 2 (19) Type of remote sensor protective hose
00 Without
13 PVC hose, black
(20) Protective hose length (insulation from housing)
0 Without
(21) Extra codes
000 Without
061 UL approval
402 Case protection type IP54
702 Snap-action switch with gold plating
749 Setting range with 250 angular degrees (only STB/STW)
V9.00/EN/00485235/2025-10-27 Page 18/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Trademark information All trademarks and trade and company names used are the property of their rightful owners or authors.
758 Tightening band for surface probe
a Further control ranges/limit value ranges up to 350 °C upon request (up to 500 °C without approval). b Special length upon request. c For a control range end value greater than 150 °C, select process connection 76 for mounting with a protective sleeve. Choose the protective sleeve according to data sheet 606710, screw-in sleeve "20" with thread G 1/2 made of stainless steel (CrNi). d Only selectable with control range 20 to 280 °C (ATW). e Spiral probe for room thermostat (with process connection 15). Order example 603070 / 0001 - 5 - 021 - 671 - 000 - 000 - 70 - 00 - 2000 - 00 - 40 - 00 - 10 - 6 - - - - / ,... a a List extra codes in sequence, separated by commas. 00 - 20 - 20 - 00 - 0 / 000
V9.00/EN/00485235/2025-10-27 Page 19/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Accessories (according to product group 606710) Thermowell set Thermowell with sealing collar Clamp for strain relief Plate for surface-mounted thermostat Screw for surface- mounted thermostat Suitable for 1 probe Part no. Type Abbre- viation Connection Ø sleeve × fitting length EL Material Pressure loading capacity at 150 °C
60003177 Thermowell for
heatTHERM, 1 probe
28 G 1/2 8 × 100 mm Brass/
60003203 8 × 150 mm 60003171 8 × 200 mm 60003172 8 × 100 mm Stainless steel/ 1.4571 88 bar 60003205 8 × 150 mm 60003173 8 × 200 mm Thermowell set Thermowell with sealing collar Clamp for strain relief Plate for surface-mounted thermostat Screw for surface- mounted thermostat Suitable for 2 probes Part no. Type Abbre- viation Connection Ø sleeve × fitting length EL Material Pressure loading capacity at 150 °C
60003178 Thermowell for
THERM, 2 probes
29 G 1/2 2 × 8 × 100 mm Brass/
60003204 2 × 8 × 150 mm 60003174 2 × 8 × 200 mm Thermowell set Thermowell with sealing collar Pressure spring Clamp for strain relief Plate for surface-mounted thermostat Screw for surface- mounted thermostat Suitable for 2 probes Part no. Type Abbre- viation Connection Ø sleeve × fitting length EL Material Pressure loading capacity at 150 °C
60003175 Thermowell for
THERM, 2 probes
49 G 1/2 15 × 100 mm Stainless steel/
1.4571 48 bar 60003206 15 × 150 mm 60003176 15 × 200 mm Adapter piece for thermowell a a Necessary for thermowell with process connection "20" or "23. Material Part no. Steel/nickel-plated 00507273
V9.00/EN/00485235/2025-10-27 Page 20/20Data Sheet 603070 -802*PE+ &R.* 'HOLYHU\\DGGUHVV 0DFNHQURGWVWUDH )XOGD*HUPDQ\\ 3RVWDODGGUHVV )XOGD*HUPDQ\\ 3KRQH )D[ (PDLO PDLO#MXPRQHW ,QWHUQHW ZZZMXPRQHW -8028./7' -802+RXVH 7HPSOH%DQN5LYHUZD\\ +DUORZ(VVH[&0'<8. 3KRQH )D[ (PDLO VDOHV#MXPRFRXN ,QWHUQHW ZZZMXPRFRXN -8023URFHVV&RQWURO,QF -R\\5RDG (DVW6\\UDFXVH1<86$ 3KRQH )D[ (PDLO LQIRXV#MXPRQHW ,QWHUQHW ZZZMXPRXVDFRP 60307000T10Z003K000 Use of electroplated nickel-plated brass protective sleeves Electroplated nickel-plated brass protective sleeves are generally suitable for permanent contact with drinking water under the following conditions:
- The nickel plating is intact and the coating is undamaged.
- The fitting is regularly inspected for corrosion or damage.
- Damaged surfaces are repaired or the fittings are replaced. Regular inspection and evaluation of electroplated nickel-plated brass protective sleeves, as determined by the user, is essential.