JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA Phone: 315-437-5866 1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com Data Sheet 603051 V3.00/EN/00439872 Surface-mounting thermostats, type series AMTHF with 2, 3 or 4 1-pole snap switches Types Types Switching function Circuit stageswith rigid shaft with capillary AMTHFs-13 AMTHF f-13 TR 2 AMTHFs-133 AMTHF f-133 TR 3 AMTHFs-1333 AMTHF f-1333 TR 4 AMTHFs-23 AMTHF f-23 TW 2 AMTHFs-233 AMTHF f-233 TW 3 AMTHFs-2333 AMTHF f-2333 TW 4 Type AMTHFs-13 Type AMTHFf-13 Brief description Add-on thermostats are used to control and monitor thermal processes. The devices of type series AMTHF are available with 2, 3 or 4 switching stages as temperature controllers (TR) and temperature monitors (TW). The sequential gap in Kelvin for the individual circuit stages is fac- tory-set fixed as per customer request. Add-on thermostats operate according to the fluid ex- pansion principle, a microswitch is used as an electrical switching element. Switching function Temperature controller (TR) and temperature monitor (TW) If the temperature exceeds the setpoint value set on the temperature probe, the microswitch will be tripped by the transmission mechanics and the current circuit opened or closed. The mi- croswitch is reset to its original status once the setpoint value set is gone below (by the hyster- esis). Special features
- Protection rating IP 54
- tested as per DIN EN 14597 (replacement for DIN 3440)
V3.00/EN/00439872 Page 2/9 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: 315-437-5866 1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com Technical data Control range and probe table — fluid-filled 1 Values in brackets only on request taking the operating statuses and the desired capillary length into consideration Control range and probe table — gas-filled Capillary and temperature probe Note: If the max. admissible temperature is not reached on the probe, capillary and switching head, it is possible to increase the capillary length, where it is limited to 1, 2 or 3 m as per the control range and probe table, on request. Please specify the temperature values occurring on the thermostats. Control / limit value ranges Hysteresis max. probe temperature max. switch head temperature possible capillary lengths in m max. sequential gap K Probe length dimension "L" in mm, Probe Ø "d" in mm Ø" 6 "=S t a n d a r d ø 6 ø 8 -20 to +040 2.5 + 050 + 050 + 095 + 100 +050 +050 +050 (80) +050 (80)1 245 245 138 103 145 145 0 to +050 2.5 + 060 + 060 + 105 + 110 +060 +060 +060 (80) +060 (80)1 283 283 159 117 165 165 101 +20 to +090 2.5 + 115 + 115 + 140 + 175 +080 +080 +080 +080 210 210 121 127 127 0 to +100 2.5 + 125 + 125 + 165 + 200 +080 +080 +080 +080 100 157 157 100 100 +30 to +110 2.5 + 135 + 135 + 170 + 200 +080 +080 +080 188 188 110 116 116 0 to +150 2.5 + 173 + 173 + 200 +080 +080 +080 113 113 0 to +200 1 2.5 + 230 + 080 1 20 40 113 78 +50 to +200 1 2.5 + 230 + 080 1 15 30 139 92 +50 to +250 2.5 + 228 + 228 + 300 +080 +080 +080 100 105 105 +50 to +300 1 2.5 + 345 + 345 +080 +080 2 25 50 87 61 Control / limit value ranges Hysteresis max. probe temperature max. switch head temperature possible capillary lengths in m max. sequential gap K Probe length dimension "L" in mm, Probe Ø "d" in mm Ø" 6 "=S t a n d a r d ø 6 ø 8 +20 to +400 6 + 460 + 500 +080 +080 5 75 200 237 127 137 +20 to +500 + 530 + 575 + 575 +080 +080 +080 250 278 176 158 106 Type Scale limit value Capillary Temperature probe Remarks AMTHF up to 200 °C Copper (Cu), ø 1.5mm Material No. Cu-DHP Copper (Cu), Material No. Cu-DHP hard soldered – up to 350 °C Copper (Cu), ø 1.5mm Material No. Cu-DHP Stainless steel (CrNi), Material No. 1.4571 hard soldered – up to 500 °C Stainless steel (CrNi), ø 1.5mm Stainless steel (CrNi), Material No. 1.4571 welded – up to 350 °C Stainless steel (CrNi), ø 1.5mm Stainless steel (CrNi), Material No. 1.4571 welded against surcharge Capillary length 1000 mm, max. 5000 mm as standard min. bending radius of the capillary 5m m
V3.00/EN/00439872 Page 3/9 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: 315-437-5866 1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com Electrical data Operating data Switching element 2, 3 or 4 1-pole snap switch Microswitch with change-over contact max. contact rating Hysteresis switching function N/C contact, terminal 2 N/O contact, terminal 4 TR, TW AC 230 V +10%, DC 230 V +10%, 0.25A AC 230 V +10%, DC 230 V +10%, 0.25A TR, TW 1% , 3% DC 230 V +10%, 0.25A Contact reliability To ensure high switching reliability, we recommend a minimum load of: AC / DC = 24 V, 20 mA Rating surge voltage 1500 V (via the switching contacts 400 V) Overvoltage category II Required fuse rating see max. contact rating Electrical connection Screw connection up to 2.5 mm2 cable cross section Hysteresis in % of the control / limit value range Switching function with fluid-filled measuring system Rated value Possible process value TR, TW 2.5 2.5 max. 3.5 serial 55 m a x . 6 o n r e q u e s t 77 m a x . 8 o n r e q u e s t 11 m a x . 2 S u r c h a r g e with gas-filled measuring system 55 m a x . 1 1 s e r i a l 6 6 max. 14 on request 10 10 max. 16 on request 3 2.5 max. 4 Surcharge Sequential gap for multi-pin version with hysteresis Sequential gap from the scale range Switching point accuracy of the sequential gaps from the scale rangeminimum maximum 2.5% 3%, 5% 6%, 7%, 10% as per control range table ≤ 1% ≤ 1% <2 % <3 % The sequential gap is specified in K in relation to the set point value of contact deck I. Prefix - = switching prior to reaching the set point value, Prefix + = switching after reaching the set point value. Enter "0" for the sequential gap for a simultaneously switching version. Switching point accuracy in % of the control/limit value range Switching function Hysteresis in the upper third of the scale or limit valuefluid-filled gas-filled T R 1% , 2 . 5% 3% , 5% 6% , 1 0% ±1.5 % ±3 % ±4 % T W 1% , 2 . 5% 3% , 5% 6% , 1 0% ±1.5 % ±3 % ±4 % medium ambient temperature influence When the ambient temperature on the switch head and/or the capillary deviates from the calibration temperature +22 °C, a switch point offset occurs. Higher ambient temperatures = lower switching point Lower ambient temperature = higher switching point For temperatures with scale limit value / limit value TR, TW TR, TW TR, TW Hysteresis in % 1/2 . 5 5 7 1/2 . 5 5 3/5 6 1 0 Ambient temperature influence on the switch head in %/K Ambient temperature influence on the capillary in %/m 0.05 · K · m 0.09 · K · m 0.04 · K · m 0.05 · K · m If the operating temperature on the switch head deviates essentially from the ambient calibration temperature +22 °C, this can be taken into account on request during adjustment against surcharge.
V3.00/EN/00439872 Page 4/9 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: 315-437-5866 1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com Operating data Case Process connection* Note: Physical and toxic features of the expansion means, which could occur in the event of a measuring system break. 1 There is currently no statement by the health authority concerning hazards to health in the event of short-term exposure and low concentration, e.g. measuring system break. Approvals/approval marks Permissible storage temperature -50 to 50 °C admissible ambient temperature during use max. 80 °C Rated position as per DIN 16257, NL 0 to NL 90 (different rated positions on request) serial Case lid: Polycarbonate, shock resistant Case bottom section: Die-cast aluminum, lacquered Color: pebble gray RAL 7032 Color: anthracite gray RAL 7015 Set point adjustment AMTHF.-1... Switching point adjustable from the outside using the rotary knob AMTHF.-2... The switching point can be adjusted by means of a screwdriver once the case lid has been removed Protection class EN 60 529-IP 54 Cable inlet serial: self-sealing grommet M 20 × 1.5, sealing range 8-10 mm Weight approx. 0.8 kg Switch head fastening, type series AMTHFf with capillary serial Screw-connection by means of co unter nut M 18 × 1 on the case stud, capillary outlet on the case stud Extra code 711 with 2 screws through the case bottom section, lateral capillary outlet on the case, lid and bottom part made of plastic
764 Fastening flange made of steel sheet, capillary outlet on the case stud
248 Wall bracket
150 °C Sheath "20“ Scale limit value exceeding 150 °C Sheath "30“ Screw-in sleeve with screw-in spigot G 1/2 form A as per DIN 3852/ Screw-in sleeve with screw-in journal G 1/2 form A as per DIN 3852/2 and intermediate piece, to ensure that the max. admissible ambient temperature of +80 °C is not exceeded on the case Type series AMTHFf with capillary plain cylindrical probe "10" (standard) Screw-in sheath "20" (on request) Screw-in sleeve with screw-in spigot G 1/2 form A as per DIN 3852/2 and clamping piece with locking screw to lock the probe Material Sheath "20“ Sheath "30“ up to +150 °C CuZn as a standard over +150°C CrNi over +150 °C CrNi Fitting length S Standard lengths: 100, 120, 150, 200 or 300; different lengths on request Immersion tube Ø D = 8 mm, D = 10 mm Control range with scale limit value Hazardous re- actions Fire and explosion hazard hazardous to waters Information about toxicology Ignition temperature Explosion limit irritant dangerous to health toxic < +200 °C no + 355 °C 0.6 - 8 V% Yes Yes 1 no ≥ 200 °C ≤ +300 °C no + 490 °C - - Yes Yes 1 no > 350 °C ≤ +500 °C no no no no no no no Approval marks Inspection authority Certificates/ inspection number Inspection basis Valid for EAC Gost Norm AG on demand Techni cal rules of the customs union Russia/Belarus/Kazakhstan AMTHF
V3.00/EN/00439872 Page 5/9 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: 315-437-5866 1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com Connection diagrams Dimensions AMTHF-13 AMTHF-23 AMTHF-133 AMTHF-233 AMTHF-1333 AMTHF-2333 AMTHFs-1... Process connection "20" with screw-in sheath AMTHFs-2... Process connection "30" with screw-in sheath and intermediate piece for scale value exceeding +150 °C 120 G D S 120 S ca. 91 D Ø9 0
V3.00/EN/00439872 Page 6/9 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: 315-437-5866 1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com Dimensions AMTHFf-1... Process connection "10" plain cylindrical probe AMTHFf-2.../711 Capillary outlet lateral on the case, with plain cylindrical probe, process connec- tion "10" AMTHFf-2.../764 with "72" sheet steel flange with screw-in sheath "20" 120 d L 120 d L D Ø 6.5 G 69 71 S 120
V3.00/EN/00439872 Page 7/9 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: 315-437-5866 1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com Dimensions AMTHFf-1.../248 with "73" wall support with screw-in sheath "20" S D G 120
V3.00/EN/00439872 Page 8/9 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: 315-437-5866 1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com Order details Surface-mounting thermostats, type series AMTHF Order code (1) Basic type
603051 Surface-mounting thermostat, type series AMTHF with 2, 3 or 4 1-pole snap switches
(2) Basic type ex tension (function) 0013 AMTHF.-13 Temperatu re controller 2-pin 0023 AMTHF.-23 Temperature monitor 2-pin 0133 AMTHF.-133 Temperature controller 3-pin 0233 AMTHF.-233 Temperature monitor 3-pin 1333 AMTHF.-1333 Temperature controller 4-pin 2333 AMTHF.-2333 Temperature monitor 4-pin (3) Design 1A M T H F s with rigid shaft 2A M T H F f with capillary (4) Control / limit value ranges 013 -20 to + 040 °C 021 0 to + 050 °C 041 +20 to + 090 °C 025 0 to +100 °C 052 +30 to +110 °C 027 0 to +150 °C 028 0 to +200 °C 062 +50 to +200 °C 063 +50 to +250 °C 064 +50 to +300 °C 045 +20 to +400 °C 046 +20 to +500 °C (5) Hysteresis 10 1% of the scale range with flui d-filled measuring systems25 2.5% 50 5% 70 7% 30 3% of the scale range with gas-filled measuring systems50 5% 60 6% 01 10% (6) Capillary length (specifications in mm) 0A M T H F s without capillary 1000 1000 mm 2000 2000 mm 3000 3000 mm 4000 4000 mm 5000 5000 mm . . . . (Special length, spec ifications in plain text) (7) Capillary material
00 AMTHF s without capillary
40 Cu (Copper)
20 CrNi (stainless steel)
V3.00/EN/00439872 Page 9/9 JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. East Syracuse, NY 13057, USA Phone: 315-437-5866 1-800-554-5866 Fax: 315-437-5860 E-mail: info.us@jumo.net Internet: www.jumousa.com Order details Surface-mounting thermostats, type series AMTHF ** For different connection types and sheaths, please refer to data sheet 606710. Sequential gap for 2-, 3- and 4-pin devices: Please specify in plain text (e.g. +2K, +5K, +8K) Order code (8) Process connection* 10 plain cylindrical probe (only for AM. f)
20 Screw-in sheath
30 Screw-in sheath
(9) Thread of process connection* 00 without thread (proce ss connection "10")
13 External thread G 1/2
(10) Material of process connection 00 only with proc ess connection "10"
46 CuZn (Brass)
20 CrNi (Stainless steel 1.4571) (11) Fitting length "S“ (i mmersion tube length)
000 AMTHF f without sheath
. . . . (Special length, spec ifications in plain text) (12) Diameter "D" (immersion tube diameter)
00 AMTHF f without sheath
(13) Diameter "d" (probe diameter) 66 m m 88 m m (14) Extra codes 000 no extra code
711 Switch head fastening with 2 scre ws through the case bottom section,
lateral capillary outlet on the case, lid and bottom part made of plastic Sequential gap: Order code: Order example: 603051 / 0133 - 2 - 025 - 25 - 2000 - 40 - 10 - 00 - 00 - 000 - 00 - 6 / 248