603-1 TELEDYNE | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 3
Technical content
603 10 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2002 TELEDYNE RELAYS 603\\072002\\Q1 ENVIRONMENTAL SPECIFICATION Min Max Units Operating Temperature Storage Temperature –55 +100 °C Junction Temperature (TJ) 150 °C Dielectric Strength 1500 Vac Isolation 10 9 Ohms Thermal Resistance (θJA)3 0 °C/W Thermal Resistance (θJC)1 0 °C/W OUTPUT (LOAD) SPECIFICATION Min Max Units Load Voltage Rating 603-1, -2 3 50 Vdc 603-3, -4 250 Vdc Output Current Rating 603-1 2 Adc 603-2 5 Adc 603-3, -4 5 Adc On-State Voltage Drop 603-1, -2 1.5 Vdc 603-3, -4 2 Vdc Output Leakage Current 603-1 (25°C) 10 mA 603-2 (25°C) 15 mA 603-3, 603-4 (25°C) 20 µA 603-3, 603-4 (100°C) 100 µA Turn-On Time 603-1, -2 100 µs 603-3, -4 120 µs Turn-Off Time 603-1, -2 300 µs 603-3, -4 150 µs Capacitance (Input to Output) 603-1, -2 20 pF 603-3, -4 15 pF NOTES 1. The basic part number provides for screw terminals only. To order PC mounting pins, add suffix “P” to part number. For quick-disconnect terminals, add sufffix “Q” to part number. 2. Relays mounted on heat sink with silicon grease. 3. Rise and fall times of input signal must be less than 1 ms or damage to output stage may result. 4. All electrical parameters at 25 °C unless otherwise specified. INPUT (CONTROL) SPECIFICATIONS Min Max Units Control Voltage Range (See Note 3) 603-1, -2 3 32 Vdc 603-3 4 10 Vdc 603-4 10 32 Vdc Input Current 603-1, -2 @32Vdc 36 mA 603-3 @5Vdc 16 mA 603-4 @28Vdc 35 mA Must Turn-On Voltage 603-1, -2 3 Vdc 603-3 4 Vdc 603-4 10 Vdc Must Turn-Off Voltage 603-1, -2 0.8 Vdc 603-3, -4 0.4 Vdc Reverse Voltage 601-1, -2 –32 Vdc
© 2002 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com 603 11 603\\072002\\Q1 Series 603 CHARACTERISTICS CURVES Figure 3 – 603-1 load current vs. temperature Figure 4 – 603-2 load current vs. temperature Figure 7 – 603-3, -4 load current vs. temperature Figure 8 – 603-3, -4 input current vs. control voltage Ambient Temperature (˚C) 01 0 2 0 3 0 4 0 5 06 0 7 08 0 Load Current (A) Mounted on 1.3˚C/W heat sink (see note 2) Unmounted Ambient Temperature (˚C) 01 0 2 0 3 0 4 05 0 6 07 08 Load Current (A) Mounted on 1.3˚C/W heat sink (see note 2) UNMOUNTED Ambient Temperature (˚C) 01 0 2 0 3 0 4 0 5 06 0 7 0 8 0 Load Current (A) Mounted on 1.3˚C/W heat sink (see note 2) Unmounted 90 10 0 Control Voltage (Vdc) 05 1 0 15 20 25 30 Typical Control Current (mA) 603-3 603-4 Control Voltage (Vdc) 05 1 0 15 20 25 30 3 5 Typical Control Current (mA)
50 Vdc
0.01 1.0 10.0 100 10000.1 Surge Duration (ms) — Non-Repetitive
40 Vdc
30 Vdc
20 Vdc
Surge Current (% Rated Current) Figure 5 – 603-1, -2 input current vs. control voltage Figure 6 – 603-1, -2 maximum surge as function of load voltage