Z8 DIGITAL TELEVISION CONTROLLERS

FEATURES

Z8-Based CMOS Microcontroller for Consum- er Television, Cable Box, and Satellite Re- ceiver Applications 42-Pin SDIP Package except Z90239 (124 PGA) Z8® MCU Core at 6 MHz Mask ROM sizes Available in 16 and 24KB Ten 6-bit Pulse Width Modulators One 14-bit Pulse Width Modulator On-Chip Infrared (IR) Capture Registers Four Channel 4-bit Analog-to-Digital Converter Twenty Seven General Purpose I/O Pins I2C Master Serial Communication Port On Screen Display (OSD) Section Supports Displays up to 10 rows by 24 Columns with

256 Characters

Character Cell Resolution of 14 Pixels by 18 Scan lines Variable Inter-row Spacing from 0–15 Horizontal Scan Lines Foreground and Background Colors Fully Programma- ble by Character GENERAL DESCRIPTION The Z9023X Digital Television Controller (DTC) family is ZiLOG’s latest and most powerful Z8-based DTC product offering. These parts feature larger system RAM and ROM options, together with a host of new features including a new color palette system, flexible inter-row spacing, higher character cell resolution, background mesh effect, dedicated I.R. capture registers, on-chip Analog-to-Digital conver- sion, and a hardware Master mode I2C interface. The famil- iar Z8 core in combination with these advanced features makes the Z9023X family an ideal choice for low to mid- range televisions in both PAL and NTSC markets. The Z9023X family consists of three basic device types; ICE Chip (Z90239), ROM Mask Parts (Z90233/Z90234), and OTP Part (Z90231). The OTP (Z90231) supports field pro- grammable 32KB system ROM. ICE Chip (Z90239) is used in Z90239 Emulator and ProtoPak. As described above, Z90233 supports 16KB system ROM and Z90234 supports 24KB system ROM for mask. The Z9021X family takes full advantage of the Z8’s ex- panded register file space to offer greater flexibility in On Screen Display creation. Note: All signals with an overline, “ ”, are active Low. For ex- ample, B/: (WORD is active Low, only); %/W (BYTE is active Low, only). Device ROM (KB) RAM (Bytes) I/O Lines1 Voltage Range Z90231 32(OTP) 236 4.5V to 5.5V Z90233 236 4.5V to 5.5V Z90234 236 4.5V to 5.5V Z90239 32(ext.) 236 4.5V to 5.5V Note: +VEQWPVUCNNOWZGF+1RQTV

Figure 1. Functional Block Diagram

Figure 2. 42-Pin SIDP Pin Identification

Table 1. Z90231/233/234 42-Pin SDIP Package

0 Volts

  1. It is Input on POR. It must be configured to be output ports for PWM applications

itive current flows into the referenced pin (Figure 3). Figure 3. Test Load Diagram

Part_Number Z8 Digital Television Controllers ZiLOG P R E L I M I N A R Y CP00300-TVX0698 DC CHARACTERISTICS 6#Q%VQ 8&& 8VQ (15%/*\\ Symbol Parameter Min Typical Max Units Conditions VDD Power Supply Voltage 4.5 5.00 5.5 V VIH Input Voltage High 0.7VDD VDD V VIL Input Voltage Low 0.2VDD V VIHC Input XTAL/Osc in High 0.7VDD VCC V VILC Input XTAL/Osc In Low 0.07VDD V VOH_ST Output Voltage High VDD–0.4 4.75 V IOH=–2mA for standard drive VOL_ST Output Voltage Low 0.16 0.4 V IOL=2.00mA for standard drive VOH_LE Output Voltage High VDD–0.4 V IOH=–0.98mA for low EMI drive VOL_LE Output Voltage Low 0.4 V IOL=0.66mA for low EMI drive VHY Schmitt Hysteresis 0.1VDD 0.8 V IIR Reset Input Current –46 –80 uA VRL=0V IIL Input Leakage –3.0 0.01 3.0 uA 0V,VDD IOL Tri-State Leakage –3.0 0.02 3.0 uA 0V,VDD ICC Supply Current mA All inputs at rail;outputs floating ICC1 HALT Mode Current 3.2 mA All inputs at rail;outputs floating ICC2 STOP Mode Current 0.1 uA All inputs at rail;outputs floating Note: 6[RKECNXCNWGUOGCUWTGFCVQ%/KPKOWOCPF/CZKOWOXCNWGUKPFKECVGFHTQOQ%VQQ%

Z8 Digital Television Controllers CP00300-TVX0698 P R E L I M I N A R Y AC CHARACTERISTICS No Symbol Parameter Min Max Unit TpC Input clock period 166 1000 ns TrC, TfC Clock input raise and fall ns TwC Input clock width ns TwHSYNCL Timer input low width ns TwHSYNCH Timer input high width 3TpC TpHSYNC Timer input period 8TpC TrHSYNC, TrHSYNC Timer input raise and fall 100 ns TwIL Int request input low ns TwIH Int request input high 3TpC TdPOR Power-On reset delay 100 ms TdLVIRES Low voltage detect to internal RESET condition 200 ns TwRES Reset minimum width 5TpC TdHsOl Hsync start to Vosc stop 2TpV 3TpV TdHsOh Hsync start to Vosc start 1TpV

Figure 4. Timing Diagram

Z8 Digital Television Controllers CP00300-TVX0698 P R E L I M I N A R Y Pre-Characterization Product: The product represented by this CPS is newly introduced and ZiLOG has not completed the full characterization of the product. The CPS states what ZiLOG knows about this product at this time, but additional features or non-conformance with some aspects of the CPS may be found, either by ZiLOG or its customers in the course of further application and characterization work. In addition, ZiLOG cautions that delivery may be uncertain at times, due to start-up yield issues. © 1998 by ZiLOG, Inc. All rights reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of ZiLOG, Inc. The information in this document is subject to change without notice. Devices sold by ZiLOG, Inc. are covered by warranty and patent indemnification provisions appearing in ZiLOG, Inc. Terms and Conditions of Sale only. ZILOG, INC. MAKES NO WARRANTY, EXPRESS, STATUTORY, IMPLIED OR BY DESCRIPTION, REGARDING THE INFORMATION SET FORTH HEREIN OR REGARDING THE FREEDOM OF THE DESCRIBED DEVICES FROM INTELLECTUAL PROPERTY INFRINGEMENT. ZILOG, INC. MAKES NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PURPOSE. ZiLOG, Inc. shall not be responsible for any errors that may appear in this document. ZiLOG, Inc. makes no commitment to update or keep current the information contained in this document. ZiLOG’s products are not authorized for use as critical components in life support devices or systems unless a specific written agreement pertaining to such intended use is executed between the customer and ZiLOG prior to use. Life support devices or systems are those which are intended for surgical implantation into the body, or which sustains life whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. ZiLOG, Inc.