Technical content
02 | Keysight | M9187A PXI Digital I/O Control Module - Data Sheet Overview Product Description The Keysight Technologies, Inc. M9187A module can be configured as 32 channels of independent input and out - put or 32 channels of configurable I/O. The digital input is designed to accept a wide range of signal inputs by using a configurable signal input threshold. This allows you to read and compare input signals to specific logic high and low voltages, and then acquire the status of individual or all 32 channels with a single command. The digital outputs offer flexibility in configuration with active low- or high-side drive and support for open-collector/open-drain connections. Installation and configuration is fast and easy with standard cable connections or an optional connector block, soft front panels, and Keysight Connection Expert. In addition, software drivers support the most common programming environments such as Visual Studio, C, C++, Visual Basic, MATLAB, and LabVIEW.
Applications
– Aerospace and defense – Automotive – Electronic test – Medical – Semiconductor
Features
– Flexible configuration of 32 channels for independent input and output or configurable I/O – Programmable input thresholds and flexible output drive capability – Robust input and output protection – Easier and faster PXI test system development – Reliable measurements from robust, high-pin-count interconnects – 32 input channels and 32 output channels – 50 V input with 100 V over voltage protection and fully protected outputs – Software drivers support the most common programming environments – Optional connector block, soft front panels, and Keysight Connection Expert Customer Values – Provides the flexibility to meet your testing needs – Reliable performance – Work in your programming environment of choice and reduce development time – Fast and easy module installation and configuration
or PXIe hybrid slot connectors. and update IVI instrument and soft front panel drivers. minimal software adjustments. wide selection of instrument program interfaces. Figure 1. Digital I/O soft front panel
less frequently changing inputs (< 10 KHz). open collector or open drain driver applications. FP_Gnd is connected to the chassis ground. Figure 2. M9187A 32 inputs, 32 outputs, 0.3 V to 50 V.
05 | Keysight | M9187A PXI Digital I/O Control Module - Data Sheet Specifications and Characteristics (continued) General specifications Channels 32 input and 32 output or 32 bit I/O Input/output specifications Input specifications 1 Channels 32 inputs Impedance (typical) 1 x 10 5 Ω, ± 5% Max voltage 2 +50 V Logic threshold (common to all inputs) Voltage range (for each level) Voltage accuracy (typical) Resolution (typical) Dual levels +0.3 V to +50 V ± 200 mV 12.21 mV (50 V/4095 counts) Readback settling time 3 50 μS Output specifications 1 Channels 32 outputs Max voltage +50 V Output states, individually controlled per channel Driven high, driven low, off Low-side driver 4 Max current Resistance (at max current) (typical) Off state drain current
0.5 A per channel, 10 A total per module
< 700 mΩ 5 uA High-side driver Vext (user supplied, common to all outputs) 5 Output voltage Max current Standby current +5 to +50 V Vext to 1.5 V
0.4 A per channel, 10 A total per module
2 uA (typical)/10 uA (maximum) Output protection 6, 7 Current limited, over voltage, thermal Output states Driven high, driven low, or off 1. Input and output channels may be wired together by the user for software configurable I/O. 2. Inputs are overvoltage protected to 100 V. 3. Read back settling time required after threshold change, input change, or channel selection. 4. Vext connection not required for open collector/open drain low-side drive. 5. Relative to front panel ground connections. 6. Overvoltage limit allows direct drive of inductive loads such as relay coils. 7. All high side drivers are in connected together in a single bank on the PCB. Do not apply different voltages to the V ext pins
06 | Keysight | M9187A PXI Digital I/O Control Module - Data Sheet Specifications and Characteristics (continued) General specifications Slot type PXI 1 slot Connector type 78-pin Dsub connector block or cable Environmental characteristics 1, 2 Temperature Operating: 0° to 55°C Non-operating: –40° to +70°C Relative humidity Relative humidity: Up to 95% R.H. at 40˚ C, non-condensing, pollution degree 1 EMC European EMC Directive 2004/108/EC – IEC/EN 61326-1 – CISPR Pub 11 Group 1, Class A – AS/NZS CISPR 11 – ICES/NMB-001 Canadian ISM device ICS-001 Safety European Low Voltage Directive 2006/95/EC - ETL, UL/IEC/EN 61010-1, 2nd Edition Altitude under relative humidity Altitude: up to 4.6 km (15,000 ft) Warm-up time 45 minutes, max 1. Samples of this product have been type tested in accordance with the Keysight Environmental Test Manual and verified to be robust against the environmental stresses of storage, transportation, and end-use; those stresses include, but are not limited to temperature, humidity, shock, vibration, altitude, and power line conditions. 2. Test methods are aligned with IEC 60068-2 and levels are similar to MIL-PRF-28800F class 3. Physical characteristics Dimensions – 3U/1-slot PXI/CompactPCI ® standard – Connector slot compatibility: cPCI (J1), PXI-1, PXIe hybrid slot – Front panel complies with IEEE1101.10 certification and compliance Weight 0.16 kg (0.35 lbs) Power requirements (max), (nominal)
5 V 100 mA
3.3 V 0 mA
+12 V 50 mA –12 V 50 mA
07 | Keysight | M9187A PXI Digital I/O Control Module - Data Sheet Specifications and Characteristics (continued) 1. Because of the installation procedure, less memory may required for operation than is required for installation 2. NET Framework Runtime Components are installed by default with Windows Vista and Windows 7. Therefore, you may not need this amount of available disk space. System requirements Operating systems W indow s X P, Service Pack 3 or later (32-bit)t Windows Vista, SP1 and SP2 (32-bit and 64-bit), Business, Ultimate, Enterprise, Home Basic, and Home Premium Windows 7 (32-bit and 64-bit) Starter, Home Basic, Home Premium, Professional, Ultimate, Enter - prise Processor speed 600 MHz or higher required
800 MHz recommended
1GHz 32-bit (x86), 1GHz 64-bit (x64), no support for Itanium 64 1GHz 32-bit (x86), 1GHz 64-bit (x64), no support for Itanium 64 Available memory 256 MB minimum (1 GB or greater recommended)
1 GB minimum 1 GB minimum
Available disk space¹ 1.5 GB available hard disk space, includes: – 1 GB available for Micro - soft .NET Framework 3.5 SP12 – 100 MB for Keysight IO Libraries Suite
1.5 GB available hard disk
space, includes: – 1 GB available for Micro - soft .NET Framework 3.5 SP12 – 100 MB for Keysight IO Libraries Suite space, includes: – 1 GB available for Micro - soft .NET Framework 3.5 SP12 – 100 MB for Keysight IO Libraries Suite Video Super VGA (800x600) 256 colors or more Support for DirectX 9 graphics with 128 MB graphics memory recommended (Super VGA graphics is supported) Support for DirectX 9 graphics with 128 MB graphics memory recommended (Super VGA graphics is supported) Browser Microsoft Internet Explorer 6.0 or greater Microsoft Internet Explorer 7 or greater Microsoft Internet Explorer 7 or greater
08 | Keysight | M9187A PXI Digital I/O Control Module - Data Sheet Configuration and Ordering Hardware Model Description M9187A PXI digital I/O: 32 inputs, 32 outputs, 0.3 V to 50 V Includes: Getting started guide, software drivers, and Keysight I/O libraries Accessories Model Description Y1181A PXI connector block: 78-pin, shielded, female Dsub Y1187A PXI connector cable: 78-pin, male-to-female, 1 meter Y1188A PXI connector cable: 78-pin, male-to-female, 2 meter
Related Products
M9018A 18-slot PXIe chassis: 18-slot, 3U, 8GB/s M9021A PCIe cable interface: Gen 2, x8 M9045B PCIe ExpressCard adaptor: Gen 1 Y1200B PCIe cable: x4 to x8, 2.0m (used with M9045A) M9048A PCIe desktop PC adapter: Gen 2, x8 Y1202A PCIe cable: x8, 2.0m (used with M9048A) Software Model Description Supported operating systems Microsoft Windows XP (32-bit), Microsoft Windows Vista (32/64-bit) Microsoft Windows 7 (32/64-bit) Standard compliant drivers IVI-COM, IVI-C, LabVIEW, MATLAB Supported application development environments (ADE) VisualStudio (VB.NET, C#, C/C++), LabVIEW, LabWindows/CVI, MATLAB Keysight IO Libraries Includes: VISA Libraries, Keysight Connection Expert, IO Monitor Recommended Chassis Configuration For the ultimate in speed and flexibility, combine your switches with other PXI modules in the Keysight M9018A PXIe chassis as follows: – Select a PXIe system module, PCIe cable interface, or embed - ded controller (the Keysight M9021A is recommended) – If an external computer is being used, select an appropriate PC interface card (the Keysight M9048A is recommended with an external PC) – Select an appropriate cable to connect the computer interface board to the system module (the Y1202A is recommended to connect the M9048A and M9021A) – Select rack mount and EMC filler panel kits as required
09 | Keysight | M9187A PXI Digital I/O Control Module - Data Sheet Definitions for specifications Calibration Advantage Services: Calibration Keysight Advantage Services is committed to your success throughout your equipment’s lifetime Specifications describe the warranted performance of calibrated instruments that have been stored for a mini - mum of 2 hours within the operating temperature range of 0 to 55 °C, unless otherwise stated, and after a 45 minute warm-up period. Data represented in this document are specifications unless other wise noted. Characteristics describe product performance that is use - ful in the application of the product. Characteristics are often referred to as Typical or Nominal values. – Typical describes characteristic performance, which 80% of the instruments will meet when operated over a 20 to 30 °C temperature range. Typical perfor - mance is not warranted. – Nominal describes representative performance that is useful in the application of the product when oper - ated over a 20 to 30 °C temperature range. Nominal performance is not warranted. Note: All graphs contain measured data from several units at room temperature unless otherwise noted. Calibration R-50C-011-3 3-year calibration assurance plan (return to Keysight) R-50C-011-5 5-year calibration assurance plan (return to Keysight)
10 | Keysight | M9187A PXI Digital I/O Control Module - Data Sheet This information is subject to change without notice. © Keysight Technologies, 2017 Published in USA, December 2, 2017 5990-7184EN www.keysight.com “PCIe” and “PCI EXPRESS” are registered trademarks and/or service marks of PCI-SIG. www.keysight.com/find/modular www.keysight.com/find/m9187a For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-9-7-17) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.keysight.com/find/emt_product_registration Register your products to get up-to-date product information and find warranty information. Keysight Services www.keysight.com/find/service Keysight Services can help from acquisition to renewal across your instrument’s lifecycle. Our comprehensive service offerings—one- stop calibration, repair, asset management, technology refresh, consulting, training and more—helps you improve product quality and lower costs. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience.