Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators Data Sheet Version 1.3

High precision pulse generators enhanced with versatile signal generation, modulation and distortion capabilities for: – Accurate signals to test your device and not your signal source – Versatile waveform and noise generation to be ready for today‘s and tomorrow‘s stress test challenges – Optional pattern generator to test in addition to analog, digital and mixed signal devices – Integrated into one instrument to minimize cabling, space and test time

03 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet – 1 µHz – 120 MHz pulse generation with variable rise/fall time – 1 µHz – 240 MHz sine waveform output – 14-bit, 2 GSa/s arbitrary waveforms – 512 k samples deep arbitrary waveform memory per channel – Pulse, sine, square, ramp, noise and arbitrary waveforms – Noise, with selectable crest factor, and signal repetition time of 26 days – FM, AM, PM, PWM, FSK modulation capabilities – 1- or 2- channel, coupled and uncoupled – Differential outputs – Two selectable output amplifiers: – High bandwidth amplifier Amplitude: 50 mVPP to 5 VPP; 50 Ω into 50 Ω 100 mVPP to 10 VPP; 50 Ω into open Voltage window: ± 5 V; 50 Ω into 50 Ω ± 10 V; 50 Ω into open ± 9 V; 5 Ω into 50 Ω – High voltage amplifier Amplitude: 100 mVPP to 10 VPP; 50 Ω into 50 Ω, 200 mVPP to 20 VPP; 5 Ω into 50 Ω, or 50 Ω into open Voltage window: ± 10 V; 50 Ω into 50 Ω ± 20 V; 5 Ω into 50 Ω or 50 Ω into open – Glitch-free change of timing parameters (delay, frequency, transition time, width, duty cycle) – Programming language compatible with Keysight 81101A, 81104A, 81105A, 81110A, 81130A and 81160A – ISO 17025 and Z540.3 calibration – LXI class C (rev. 1.1) compliant – Optional pattern generator: – Ideal and arbitrary bit shaped pattern up to 120 Mbit/s – Two, three or four level signals – PRBS up to 231 – 16 Mbit pattern memory – Pass through pattern for combined and physical and protocol test up to 10 Mbit/s The 81150A Pulse Function Arbitrary Noise Generator at a Glance

811 A50

04 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet – 1 µHz – 330 MHz pulse generation with variable rise/fall time – 1 µHz – 500 MHz sine waveform output – 14-bit, 2.5 GSa/s arbitrary waveforms – Up to 256k samples deep arbitrary waveform memory per channel – Pulse, sine, square, ramp, noise and arbitrary waveforms – Noise, with selectable crest factor, and signal repetition time of 20 days – FM, AM, PM, PWM, FSK modulation capabilities or 2 channel, coupled and uncoupled – Differential outputs – Amplitude: 50 Ω into 50 Ω 50 mVPP to 5 VPP 50 Ω into open 100 mVPP to 10 VPP – Voltage window: 50 Ω into 50 Ω ± 5 V 50 Ω into open ± 10 V – Glitch-free change of timing parameters (delay, frequency, transition time, width, duty cycle) – Programming language compatible with Keysight 81101A, 81104A, 81105A, 81110A, 81130A and 81150A – ISO 17025 and Z540.3 calibration – LXI class C (rev 1.1) compliant – Optional pattern generator: – Ideal and arbitrary bit shaped pattern up to 330 Mbit/s (Option 330) or

660 Mbit/s (Option 660)

– Two, three or four level signals – PRBS up to 231 – 4 Mbit pattern memory for the 1-channel instrument and 2 Mbit per channel for the 2-channel instrument – Pass through pattern for combined and physical and protocol test up to 10 Mbit/s The 81160A Pulse Function Arbitrary Noise Generator at a Glance

811 A60

05 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Couple/uncouple channels External In Trigger mode Waveform type Advanced mode Channel 2: Trigger Out Strobe Out Differential output Channel 1: Trigger Out Strobe Out Differential output USB 2.0 standard A USB 2.0 standard A USB 2.0 standard B LAN GPIB

10 MHz Ref In

10 MHz Ref Out

Modulation In 1, 2

06 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Sync out A and B: The logical trigger signal 1 or logical trigger signal 2 or logical strobe signal 1 or logical strobe signal 2 can be routed by a fully flexible internal switch matrix to Sync Out A or Sync Out B. Couple/uncouple channels External In Trigger mode Waveform type Advanced mode Channel 2: Differential output Channel 1: Differential output USB 2.0 standard A USB 2.0 standard A USB 2.0 standard B LAN GPIB In 1, 2

07 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Today‘s Challenges Require a New Generation of Test Instruments You are under pressure to get products to market faster and faster, with shrinking design schedules and increasing quality goals. The pressure is never ending. Because differentiation means survival in the marketplace, you often have to test unique functionality. Being confident in your results takes highly adaptable and efficient testing. Such challenges require a new generation of test instruments, which are: – Accurate, to test your device and not your source – Versatile, to be ready for today’s and tomorrows test challenges – Plug and play solutions, with minimal cabling, low space overhead and have many functions built-in Whichever way you look at it, this starts with accurate, versatile and uncompromising signal sources. Just test – with the signal you need. Quad versatility – optimum signal fidelity The Keysight Technologies, Inc. 81150A and 81160A Pulse Function Arbitrary Noise Generators set the standard for the next generation of lab: for fast, accurate insight into your design or device under test. Both of them offer: – Pulse generators with precise signals for performance verification and characterization function arbitrary generator – For versatile signal generation to optimize testing – For modulation to shape the signal the DUT needs – A noise generator to distort signals to build up worst case scenarios – An optional pattern generator to test in addition to analog, digital and mixed signal devices with ideal and real-world conditions The Keysight 81150A and the new Keysight 81160A Pulse Function Arbitrary Noise Generators are indispensable contributors to accelerate ideal and real-world testing. Keysight’s offering Pulse generator Noise generator Pattern generator Function arbitrary generator

08 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Pulse Generator – Test Your Device and Not Your Source Superior precision pulses with unbeatable timing stability guarantee reproducible tests. The signal quality and trigger functionality provide everything you need for trigger or system clock applications. You can change the timing parameters (delay, frequency, transition time, width, duty cycle) without dropouts or glitches. This patented, industry-leading feature means continuous operation without having to reboot or reset your device under test, for example when you are characterizing a device by sweeping the clock frequency. Apart from full control of the timing parameters, you can also adjust levels and edges as needed. Channel 1 pulse setup Both, the Keysight 81150A and the Keysight 81160A Pulse Function Arbitrary Noise Generator, are available in a 1- or 2-channel version. On the two-channel version, the channels can be uncoupled, to work independently, or coupled, for example, with a defined delay between them. Each channel provides Trigger Out, Strobe Out and differential outputs: the basis for many complex test setups. Measurement using strobe and trigger Set up complex measurements Gated burst of 4 External In Trigger Out Strobe Out Out

09 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Function Arbitrary Generator Stress Your Device to its Limit If you need further signal conditioning, the Keysight 81150A and the Keysight 81160A Pulse Function Arbitrary Noise Generators provide versatile waveforms and modulation capabilities to adapt your signal to your device’s requirements. AM, FM, FSK, PM and PWM are available at modulation frequencies up to 10 MHz and to 50 MHz. The Keysight 81150A and the Keysight 81160A Pulse Function Arbitrary Noise Generators can use internal or external modulation sources. Internal modulation can be generated from the 2nd channel or the internal modulation source of the modulated channel. Amplitude modulation Frequency shift keying modulation Pulse width modulation Frequency sweep

10 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Noise generator – repeatable and stochastic noise Jitter and noise cause misalignment of edges and levels, resulting in data errors. Noise is by its nature unpredictable because it can have many different causes, from signal interference caused by sudden voltage changes, to distortions introduced during transmission. It is important to be able to simulate noise-based malfunctions, for example, to identify the additive noise produced by receiving systems—it is cheaper to lower the noise figure than to increase the transmitter power! The Keysight 81150A and the Keysight 81160A Pulse Function Arbitrary Noise Generators let you control the quality of the noise, to test different cases, and according to various specifications. White Gaussian noise is a good approximation to many real-world situations, and creates mathematically traceable models, with statistical independent values. The Keysight 81150A and the Keysight 81160A Pulse Function Arbitrary Noise Generators provide deterministic white Gaussian noise, with a signal repetition of 20 days or 26 days respec - tively. You can decide on any arbitrary distribution, and trigger the noise to start when you need it. Setting up a measurement using trigger, strobe, modulation and carrier Gaussian curve and distribution

11 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Voltage level crest factor You can also select the crest factor out of 4 values – an indicator of signal quality – using VP/VRMS or VPP/VRMS scales, depending on the standard to which you are testing. The 81150A and the 81160A use the definition: crest factor = V P/VRMS The result is noise that combines two extremes: – Random and repeatable noise, for stress tests on one side – While still being sufficiently random Pattern Generator – Test in Addition to Analog, Digital and Mixed Signal Devices Engineers working with serial buses or designers of analog, digital and mixed signal devices require stressing their design with pattern. The optional Keysight 81150A and 81160A arbitrary bit shaped pattern generator allows sending ideal and real-world pattern. The Keysight 81150A with arbitrary bit shaped pattern (Option PAT) allows emulating overshoot, asymmetric delay and duty cycle distortion up to 120 Mbit/s, the Keysight 81160A up to 330 Mbit/s (Option 330) or even up to 660 Mbit/s (Option 660). Patterns can be easily set up and distorted at your fingertips.

12 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Pass through pattern for combined physical and protocol test up to 10 Mbit/s The 81150A and the 81160A pattern generators let you define the transitions from one bit to the other so that the previous bit influences the current bit. The user can set up own defined arbitrary bit shapes. In addition to user-defined patterns, standard patterns like PRBS up to 231 are available. The sequencer allows setting up a pre-amble sequence so that the device under test moves into test mode. Additionally to 2-level signals, it is also possible to create 3- and even 4-level signals. With the 3-level signals, it is no longer necessary to add different signals for electrical idle. 3-level signals are important e.g. for use in Ethernet environment and 4-level signals e.g. for PAM-4 applications. Besides, standard trigger modes like continuous bit and block trigger modes allow adoptions to application needs. In the bit mode you see that on every trigger, the sequence is advanced by one bit. An application example is a bit clock, which can be fed into an external clock and then into the trigger input. In the block mode the entire data block is generated once per trigger event. This is interesting for example in applications with protocol data. The 81150A and the 81160A pattern generators pass the data through to the device under test and add any kind of stress (shape and timing change). Bridge the gap between protocol and physical layer test – in real time up to 10 Mbit/s Increase your test efficiency by combining physical layer test with protocol test PRBS Sequencer 2-, 3- and 4-level signals Bit and block trigger mode NRZ Transition time Period Min voltage level Min voltage level Min voltage level Max voltage level Max voltage level Max voltage level Output waveform Bit shape waveforms (user defined) 0→0 1→0 1→10→1 NRZ mode with minimum transition times Mode Mode Bit shape Arbitrary NRZ mode with minimum transition times NRZ mode with transition time = 1/3 period Data pattern: 01001101 Stress your device to its limits – define your own bit shape Sends out protocol data; e.g. VPT 1000 for FlexRay MOD IN Pass/fail test DUTProtocol exerciser 81150A/81160A pass through pattern Protocol handshake Real-time data pass through with flexible modulation and re-stress test The pass-through pattern functionality takes the protocol data via Mod In and adds any kind of stress (shape and timing changes). Emulate effects like... – Capacitive load of the channel – Asymmetric delay – Crossing point deviations – Duty cycle distortions – Arbitrary transition times – Level noise – Delays from/to electrical idle ...By defining the transitions so that the previous bit influences the current bit

13 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Keysight 2000, 3000 and 4000 X-Series InfiniiVision oscilloscopes Keysight 33503A BenchLink Waveform Builder Pro – IntuiLInk (.wvf) – CSV (.csv) – Binary – Text (.txt) – 33500 Series ASCII (.arb) – 33500 Series Binary (.barb) – 33500 Series Sequence (.seq) – 81100 Series Sequence (.dseq) I/O library MS Excel *.csv VEE LabView Manual sampling I/O library or IVI.com I/O library or IVI.com I/O library or IVI.com Modulation of the pattern signal enables you to emulate real-world conditions. AM – amplitude of the pattern signal is multiplied by the modulation signal to emulate level distortions of the data signal e.g. sinusoidal interference. FM – frequency of the pattern signal is modulated to emulate SSC on the data signal. PM – the phase of the data bits is modulated to emulate jitter on the data signal. Modulation Connectivity Filling the arbitrary memory easily There are several possibilities for filling the arbitrary memory. There are 6 built-in, standard arbitrary waveforms, but you can also create any waveform you need, either on the instrument or on a PC, using the Keysight 33503A BenchLink Waveform Builder Pro software available for the 81150A and 81160A Pulse Function Arbitrary Noise Generators. The 33503A software is being designed for waveform creation, waveform import from Keysight scopes and waveform download to the 81150A and 81160A generators.

14 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Measurement – Anywhere and Anytime The web interface allows you to use the full functionality and feature set of the Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators from a web browser. Channel 1: set up the signal Web interface Just decide on the waveform Channel 2: add noise Choose the crest factor/probability function you need Web interface

15 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Amplifier concept Flexible signal synchronization Different applications and devices call for different bandwidth and voltage levels. Choose the performance you need. The 81150A has one trigger output and one strobe output per channel. The 81160A generates the trigger signal and the strobe signal per channel internally. Using a fully configurable switch matrix, two of the four internal signals can be routed to Sync Out A or Sync Out B.

330 MHz

81150A high bandwidth amplifier

120 MHz

50 MHz

81150A high voltage amplifier

10 V5 V

81150A has a high bandwidth amplifier and a hight voltage amplifier, whereas the 81160A covers its whole spectrum with only one amplifier. 81160A: Sync Out A and B

16 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Modes of Operation There are four components to the mode of operation: – Coupling between channels – Trigger mode – Waveform type – Advanced modes The two-channel version has two distinct modes of operation: – Coupling off: The two channels operate independently. Frequency generation for both channels is based on the same clock reference, but can be selected independently. – Coupling on: The frequency, trigger mode, waveform type and advanced mode are identical for both channels. The fix delay of channel 1 and channel 2 is the same. – Continuous: Continuous waveform, burst, sweep or modulation. The external In is not used in continuous mode. – Externally triggered: Each active transition at the external In (rising, falling or both) generates a single waveform, burst or sweep. – Externally gated: The active level (high or low) at the external In enables waveforms, bursts or sweeps. The last waveform, burst or sweep is always completed. – Internally triggered: The internal clock replaces the external trigger source. This can be applied for waveform, burst, or sweep. – Manual: This generates a single trigger. The source is either a button on the front panel or a remote command. Trigger rate (internally triggered) 81150A: 1 µHz to 120 MHz 81160A: 1 µHz to 330 MHz Trigger rate (externally triggered) 81150A: DC to 120 MHz 81160A: DC to 330 MHz Coupling between channel 1 and 2 Trigger modes

17 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Waveform Types – Standard waveforms: pulse, sine, square, ramp, noise, arbitrary – Predefined arbitrary waveforms: exponential rise, exponential fall, sin(x)/x, cardiac and DC – Pulse, sine, ramp, noise and arbitrary measured with 50 Ω source impedance into 50 Ω load impedance. Pulse characteristics 81150A 81160A Frequency range High bandwidth amplifier High voltage amplifier 1 μHz to 120 MHz 1 μHz to 50 MHz 1 μHz to 330 MHz Frequency resolution 1 μHz 1 μHz Pulse width Range High bandwidth amplifier High voltage amplifier Resolution Accuracy 4.1 ns to (period - 4.1 ns) typ. 10 ns to (period - 10 ns) 100 ps, 6 digits ± 500 ps ± 50 ppm 1.5 ns to (period - 1.5 ns) spec. 100 ps, 6 digits ± 300 ps ± 50 ppm Transition time (independent rise and fall) Range High bandwidth amplifier High voltage amplifier Resolution Accuracy High bandwidth amplifier High voltage amplifier 2.5 ns to 1000 s (10% to 90%) 7.5 ns to 1000 s (10% to 90%) 100 ps, 6 digits ± 500 ps ± 50 ppm -1000 ps to +500 ps ± 50 ppm 1.0 ns to 1000 s (10% to 90%) 100 ps, 6 digits ± 300 ps ± 50 ppm Overshoot 2% typ.1 4% typ.2 1. Overshoot disappears for transitions times > 5 ns (high bandwidth amplifier) and > 15 ns (high voltage amplifier). 2. Overshoot disappears for transition times > 2 ns. Sine characteristics 81150A 81160A Frequency range High bandwidth amplifier High voltage amplifier 1 μHz to 240 MHz 1 μHz to 50 MHz 1 µHz to 500 MHz Frequency resolution 1 μHz 1 μHz Harmonic distortion (High bandwidth amplifier 50 Ω into 50 Ω) 1 μHz to 2 MHz

2 MHz to 10 MHz

10 MHz to 35 MHz

35 MHz to 70 MHz

70 MHz to 240 MHz

1 VPP

< -62 dBc spec. < -57 dBc spec. < -45 dBc spec. < -35 dBc spec. < -22 dBc spec.

3 VPP

< -62 dBc spec. < -52 dBc spec. < -40 dBc spec. < -30 dBc spec. < -17 dBc spec. 1 µHz to 2 MHz

10 MHz to 50 MHz

50 MHz to 200 MHz

200 MHz to 500 MHz

< -65dBc spec. < -62dBc spec. < -50 dBc spec. < -30 dBc spec. < -22 dBc spec. < -63 dBc spec. < -53 dBc spec. < -40 dBc spec. < -27 dBc spec. < -20 dBc spec. Harmonic distortion (High voltage amplifier 50 Ω into 50 Ω) 1 μHz to 8 MHz

8 MHz to 50 MHz

10 VPP

< -40 dBc < -25 dBc Non-harmonic (spurious) distortion 1 μHz to 20 MHz

20 MHz to 200 MHz

200 MHz to 240 MHz

-60 dBc typ. -55 dBc typ. -50 dBc typ. 1 μHz to 1 MHz

1 MHz to 10 MHz

10 MHz to 280 MHz

280 MHz to 330 MHz

330 MHz to 500 MHz

-50 dBc typ. -55 dBc typ. -50 dBc typ. -45 dBc typ. -43 dBc typ. SSB phase noise (10 kHz offset)

1 MHz

10 MHz

100 MHz

240 MHz

500 MHz

-119 dBc/Hz typ. -115 dBc/Hz typ. -93 dBc/Hz typ. -115 dBc/Hz typ. -115 dBc/Hz typ. -110 dBc/Hz typ. -100 dBc/Hz typ.

18 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Square characteristics 81150A 81160A Frequency range High bandwidth amplifier High voltage amplifier 1 μHz to 120 MHz 1 μHz to 50 MHz 1 µHz to 330 MHz Frequency resolution 1 μHz 1 μHz Duty cycle High bandwidth amplifier High voltage amplifier (Freq/240 MHz) to 1 – (Freq/240 MHz) e.g. 60 MHz; 25% to 75% (Freq/100 MHz) to 1 – (Freq/100 MHz) e.g. 1 MHz 1% to 99% (Freq/ 660 MHz) to 1 – (Freq/ 660 MHz) e.g. 115 MHz; 25% to 75% Resolution 0.1% 0.1% Transition time (10% to 90%) High bandwidth amplifier High voltage amplifier 2.5 ns typ. fixed 6 ns typ. fixed 1.1 ns typ. fixed Overshoot 2% typ. 4% typ. Ramp characteristics 81150A 81160A Frequency range 1 μHz to 5 MHz 1 µHz to 20 MHz Frequency resolution 1 μHz 1 μHz Linearity < 0.1% (f < 10 kHz) < 0.1% (f < 10 kHz) Symmetry 0.0% to 100% 0.0% to 100% Noise characteristics 81150A 81160A Bandwidth High bandwidth amplifier High voltage amplifier 120 MHz typ. 40 MHz typ. 160 MHz typ. Amplitude distribution Selectable Gaussian, user defined Selectable Gaussian, user defined Noise type Deterministic, triggerable Deterministic, triggerable Repetition time ~ 26 days ~ 20 days

19 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Arbitrary characteristics 81150A 81160A DAC sample rate 2 GSa/s1, fixed 2.5 GSa/s, fixed Waveform length 2 to 512 k points 1-channel instrument: 2 to 256 k points 2-channel instrument: 2 to 128 k points Wavelength vs. memory access rate 2 to 512 k points at memory access rate 1,000 MSa/s1 1-channel instrument, automatic selection: 128 k to 256 k points at memory access rate 625 MSa/s 2 64 k to 128 k points at memory access rate 1,250 MSa/s 3 2 to 64 k points at memory access rate 2,500 MSa/s 2-channel instrument, automatic selection: 64 k to 128 k points at memory access rate 625 MSa/s 2 32 to 64 k points at memory access rate 1,250 MSa/s 3 2 to 32 k points at memory access rate 2,500 MSa/s DAC resolution 14 bits 14 bits Frequency range 1 μHz to 120 MHz 1 µHz to 330 MHz Frequency resolution 1 μHz 1 μHz Transition time (10% to 90%) High bandwidth amplifier High voltage amplifier 1.7 ns typ. 5 ns typ. 1.0 ns typ. Filter bandwidth High bandwidth amplifier High voltage amplifier 240 MHz typ. 80 MHz typ. 500 MHz typ. PP jitter 1 ns typ. 400 ps typ. at memory sample rate 2,500 MSa/s 1. One step linear interpolation between two memory samples. DAC clock rate is 2,000 MSa/s. 2. Three steps linear interpolation between two memory samples. DAC clock rate is 2,500 MSa/s. 3. One step linear interpolation between two memory samples. DAC clock rate is 2,500 MSa/s

20 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Advanced Modes Three advanced modes exist: – Modulation: selects the modulation type: AM, FM, PM, FSK, PWM – Sweep: for frequency sweeps – Bursts: repeats selected waveform n times A modulation input (for AM, FM, PM, FSK, PWM) for each channel is provided on the back-panel. In the two-channel instrument one channel can also modulate the other channel. Modulation In 1/modulation In 2 81150A 81160A Input range (full scale) Selectable ± 2.5 V or ± 5 V ± 2.5 V Frequency range DC to 10 MHz DC to 10 MHz Input impedance Selectable 10 kΩ, 50 Ω nom. Selectable 10 kΩ, 50 Ω nom. Connector BNC, back panel BNC, back panel AM 81150A 81160A Carrier waveforms Sine, square, ramp, arbitrary Sine, square, ramp, arbitrary Internal modulation Sine, square, ramp (up, 50%, down), noise, arbitrary Sine, square, ramp (up, 50%, down), noise, arbitrary Modulation frequency Internal External 1 mHz to 10 MHz DC to 10 MHz 1 mHz to 50 MHz DC to 10 MHz Depth 0% to 120% 0% to 120% Double-sideband suppressed carrier Selectable on/off Selectable on/off Source Internal, external, channel Internal, external, channel FM 81150A 81160A Carrier waveforms Sine, square, ramp, arbitrary Sine, square, ramp, arbitrary Internal modulation Sine, square, ramp (up, 50%, down), noise, arbitrary Sine, square, ramp (up, 50%, down), noise, arbitrary Modulation frequency Internal External 1 mHz to 10 MHz DC to 10 MHz 1 mHz to 50 MHz DC to 10 MHz Deviation range 1 μHz to 240 MHz1 1 µHz to 500 MHz1 Source Internal, external, channel Internal, external, channel PM 81150A 81160A Carrier waveforms Sine, square, ramp, arbitrary Sine, square, ramp, arbitrary Internal modulation Sine, square, ramp (up, 50%, down), noise, arbitrary Sine, square, ramp (up, 50%, down), noise, arbitrary Modulation frequency Internal External 1 mHz to 10 MHz DC to 10 MHz 1 mHz to 50 MHz DC to 10 MHz Deviation range 0 to 360˚ 0 to 360˚ Source Internal, external, channel Internal, external, channel 1. Max frequency depends on selected waveform. Modulation

21 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet FSK 81150A 81160A Carrier waveforms Sine, square, ramp, arbitrary Sine, square, ramp, arbitrary Internal modulation 50% square 50% square FSK rate Internal External 1 mHz to 50 MHz 1 mHz to 10 MHz 1 mHz to 50 MHz 1 mHz to 10 MHz Frequency range 1 mHz to 240 MHz1, 2 1 mHz to 500 MHz1 Source Internal, external, channel Internal, external, channel 1. Max frequency depends on selected waveform. 2. For export control: Effective switching time is 40 ns. PWM 81150A 81160A Carrier waveform Pulse Pulse Internal modulation Sine, square, ramp (up, 50%, down), noise, arbitrary Sine, square, ramp (up, 50%, down), noise, arbitrary Modulation frequency Internal External 1 mHz to 10 MHz DC to 10 MHz 1 mHz to 50 MHz DC to 10 MHz Deviation range 0% to 100% of pulse width 0% to 100% of pulse width Source Internal, external, channel Internal, external, channel Sweep An independent frequency sweep is provided for each channel. 81150A 81160A Waveforms Pulse, sine, square, ramp, triangle, arbitrary Pulse, sine, square, ramp, triangle, arbitrary Type Linear or logarithmic Linear or logarithmic Direction Up or down Up or down Sweep time 100 μs to 500 s 50 μs to 500 s Start frequency/stop frequency 1 μs to 240 MHz3 1 μHz to 500 MHz1 Amplitude flatness (relative to 1 kHz, 2 V PP) — 1 μHz to 500 MHz ± 0.5 dB typ. Trigger source External, internal, manual External, internal, manual Marker Frequency marker Frequency marker 3. Max frequency depends on selected waveform. Burst An independent burst capability is provided for each channel. 81150A 81160A Waveforms Pulse, sine, square, ramp, triangle, arbitrary Pulse, sine, square, ramp, triangle, arbitrary Frequency 1 μHz to 120 MHz 1 µHz to 330 MHz Modes Externally triggered, internally triggered, externally gated Externally triggered, internally triggered, externally gated # of waveforms in a burst 2 to 231 - 1 (~ 2 billion) 2 to 231 – 1 (~ 2 billion) Trigger period 16.7 ns to 9999 s 6.1 ns to 9999s Start phase 4 –360 to +360˚ –360 to +360˚ Gate source External External Trigger source External, internal, manual External, internal, manual 4. Available for all waveforms except pulse, square and ramp.

22 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Outputs Main outputs A selectable single-ended or differential output is provided for each channel on the front-panel. Max. frequency 81150A 81160A High bandwidth amplifier 120 MHz pulse/240 MHz sine 330 MHz pulse/500 MHz sine High voltage amplifier 50 MHz Out 1/Out 2 81150A 81160A Output type Single-ended or differential Single-ended or differential Amplitude (50 Ω into 50 Ω) High bandwidth amplifier 1 μHz to 120 MHz

120 MHz to 240 MHz

1 µHz to 330 MHz 1 μHz to 50 MHz 50 mVPP to 5 VPP 1 typ. 50 mVPP to 3VPP 1 typ. 100 mVPP to 10 VPP 1 typ. 50 mVPP to 5 VPP 1 typ. 50 mVPP to 3 VPP 1 typ. Amplitude (50 Ω into open, 5 Ω into 50 Ω) High bandwidth amplifier 1 μHz to 120 MHz 1 µHz to 60 MHz High voltage amplifier 1 μHz to 50 MHz 100 mVPP to 10 VPP 1 (to 9 VPP 2) typ. 100 mVPP to 5 VPP 1 typ. 200 mVPP to 20 VPP 1 typ. 100 mVPP to 10 VPP 1, 4 typ. DC amplitude accuracy ± (1.5% of setting + 5 mV) ± (1.5% of setting + 5 mV) Voltage window (50 Ω into 50 Ω) High bandwidth amplifier High voltage amplifier –5 V to +5 V typ. –10 V to +10 V typ. –5 V to +5 V typ. Voltage window (50 Ω into open, 5 Ω into 50 Ω) High bandwidth amplifier High voltage amplifier –10 V to +10 V1 (-9 V to +9 V2) typ. –20 V to +20 V typ. –10 V to +10 V typ. 4 DC offset accuracy ± 5 V voltage window ± 10 V voltage window ± 20 V voltage window ± (25 mV + 1%) ± (50 mV + 1%) ± (75 mV + 1%) ± (25 mV + 1%) ± (50 mV + 1%) Resolution 1 mV, 4 digits 1 mV, 4 digits Output impedance Selectable 50 Ω / 5 Ω nom. 50 Ω nom. Variable load impedance 0.3 Ω to 1 MΩ3 0.1 Ω to 1 MΩ Protection Short-circuit protected, overload disables main output Short-circuit protected, overload disables main output Connector BNC, front panel BNC, front panel 1. All amplitudes are single-ended amplitudes. Differential peak-peak amplitudes are twice the single-ended value. 2. 10 VPP for 50 Ω into open; 9 V PP for 5 Ω into 50 Ω . 3. Current of normal Out plus current of complement Out is limited to 440 mA per channel. 4. Only for 50 Ω into open.

23 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Clock Reference External reference output 81150A 81160A Frequency Accuracy Stability Aging 10 MHz typ. ± 50 ppm ± 2 ppm, 0 to 50 ºC ± 1 ppm per year 10 MHz spec. ± 10 ppm ± 2 ppm, 0 to 55 °C ± 1 ppm per year Output level 1 V nom. 1 V nom. Impedance 50 Ω nom., AC coupled 50 Ω nom., AC coupled Connector BNC, rear panel BNC, rear panel External reference input 81150A 81160A Lock range 10 MHz ± 500 ppm 10 MHz ± 500 ppm typ. Input level 200 mVpp to 5 Vpp 200 mVPP to 5 VPP typ. Impedance 1 kΩ nom., AC coupled 1 kΩ nom., AC coupled Connector BNC, rear panel BNC, rear panel Internal frequency characteristics 81150A 81160A Accuracy ± 50 ppm ±10 ppm Stabilty ± 2 ppm, 0 to 50 ºC ± 2 ppm, 0 to 55 ºC Aging ± 1 ppm per year ± 1 ppm per year External Input A common external input is provided for both channels on the front panel. The external input is used for external trigger or external gate modes. 81150A 81160A Frequency range DC to 120 MHz DC to 330 MHz Input range –10 V to +10 V –5 V to +5 V Maximum input amplitude 10 VPP 10 VPP Input sensitivity 200 mVPP Hysteresis low: 200 mV PP Hysteresis high: 350 mV PP Threshold Range Resolution –10 V to 10 V 100 mV –5 V to +5 V 100 mV Impedance Selectable 10 kΩ/50 Ω, DC coupled Selectable, 1 kΩ/50 Ω, DC coupled Slope Selectable, rising/falling/both Selectable, rising/falling/both Pulse width > 3.3 ns > 1.3 ns Transition time < 100 ns Connector BNC, front panel BNC, front panel Frequency counter The frequency applied to external input is measured Gate time, up to 330 MHz — 1 s, fix Accuracy — See clock reference specifications

24 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet For 81150A, a separate trigger output is provided for each channel on the front-panel. In advanced mode internally/externally modulated (AM, FM, PM, PWM), the trigger output has the frequency of the unmodulated carrier waveform, with a 50% duty cycle. For FSK modulation, the trigger output has the same frequency as the data output. That is, it alternates between the two frequencies. If noise is selected, a trigger signal is generated when noise is restarted internally, exter - nally or manually. For all other modes of operation the trigger signal (TRIGGER OUT) marks the start of each waveform period. 81150A Trigger Out 1/Trigger Out 2 81150A Output level TTL ECL Selectable TTL/ECL 0 V/2.5 V nom. –0.85 V/–1.80 V nom. Pulse width Internally triggered, continuous Externally triggered 50% duty cycle typ. 4 ns typ. Transition time (20% to 80%) 2.0 ns typ. Maximum rate 120 MHz1 Impedance 50 Ω nom. Connector BNC, front panel 1. For output frequencies > 120 MHz, the trigger rate is ¼ of the output frequency. If a frequency sweep or a FSK frequency exceeds 120 MHz, the trigger rate is ¼ of the output frequency. 81150A Trigger Outputs

25 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet 81150A Strobe Outputs A strobe output is provided for each channel on the front-panel of pulse generator 81150A. The strobe output signal has a different function, depending on the mode of operation. If no advanced mode is selected, the strobe output is a constant low. In advanced mode internally/ externally triggered or gated burst, the strobe output provides a signal indicating the duration of a burst. The rising edge of the strobe signal is synchronized to the start of the first waveform period in a burst. The falling edge is synchronized to the start of the last waveform period in the burst. In advanced mode sweep with the frequency marker off, the strobe output is a pulse with half the duration of the sweep. The strobe signal goes high at the beginning of the sweep. In advanced mode sweep with the frequency marker on, the strobe output goes high at the beginning of the sweep and goes low at the marker frequency. In pattern mode (block mode = On), the strobe output goes high at the beginning of the pattern and goes low at the last bit of the pattern. Refer to the User Guide for more details. In advanced mode internally/externally modulated (AM, FM, FSK, PM, PWM), the strobe output is the analog modulation waveform. In pattern mode (block mode = On), the logical strobe signal goes high at the beginning of the pattern and goes low at the last bit of the pattern. Refer to the User Guide for more details. 81150A Strobe Out 1/Strobe Out 2 81150A Digital output level TTL ECL Analog output level (modulator) Selectable TTL/ECL 0 V/2.5 V nom. –0.85 V/–1.80 V nom. –2.0 V to 2.0 V (full scale) Impedance 50 Ω nom. Connector BNC, front panel Min pulse width 4 ns typ. Transition time (20% to 80%) 2.0 ns typ.

26 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet 81160A Trigger and Strobe Outputs Sync Out A and Sync Out B For the one-channel instrument as well as the two-channel instrument two high speed outputs Sync Out A and Sync Out B are provided at the front panel. The Sync output signals can be configured very flexibly by an internal switch matrix to output the logical Trigger Out functionality or Strobe Out functionality according to the following switch matrix. 1-channel instrument 81160A Sync Out A source None, logical trigger signal 1, logical strobe signal 1 Sync Out B source None, logical trigger signal 1, logical strobe signal 1 It is e.g. possible, that the logical trigger signal 1 functionality is routed simultaneously to Sync. 2-channel instrument 81160A Sync Out A source None, logical trigger signal 1, logical strobe signal 1, logical trigger signal 2, logical strobe signal 2 Sync Out B source None, logical trigger signal 1, logical strobe signal 1, logical trigger signal 2, logical strobe signal 2 It is e.g. possible, that the logical trigger signal 1 functionality is routed simultaneously to Sync. Sync Out A/Sync Out B 81160A Digital output level TTL ECL Analog output level (modulator) Selectable TTL, ECL 0 V/2.5 V nom. –0.85 V/–1.80 V nom. –2.0 V to 2.0 V (full scale), Available, if routed to logical Strobe Out Impedance 50 Ω nom. Transition time 0.8 ns typ. (20%/80%) Connector BNC, front panel The logical trigger output and logical strobe output functionality is described below. Logical trigger signal The logical trigger signal is an internally generated signal that can be routed to the BNC connector of Sync Out A or Sync Out B. For the two-channel instrument, the logical trigger signal is generated for both, channel 1 and channel 2. In advanced mode internally/externally modulated (AM, FM, PM, PWM), the logical trigger signal has the frequency of the unmodulated carrier waveform with 50% duty cycle. For FSK modulation the logical trigger signal generates the same frequency as the data output — it alternates between the two frequencies. If noise is selected, a trigger signal is generated when noise is restarted internally, externally or manually. For all other modes of operation the logical trigger signal marks the start of each waveform period.

27 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Logical trigger signal 1/logical trigger signal 2 81160A Pulse width Internallly triggered, continuous Externally triggered 50% duty cycle typ. 1.5 ns typ. Maximum rate 330 MHz1 1. For output frequencies > 330 MHz, the trigger rate is ½ of the output frequency. In pattern mode with bit rate > 330 MBit/s, the trigger rate is ½ of the output frequency. If a frequency sweep or a FSK frequency exceeds 330 MHz, the trigger rate is ½ of the output frequency. Logical strobe signal The logical strobe signal is an internally generated signal that can be routed to the BNC connector of Sync Out A or Sync Out B. For the two-channel instrument, the logical strobe signal is generated for both, channel 1 and channel 2. The logical strobe signal has a different function, depending on the mode of operation. If no advanced mode is selected, the logical strobe signal is constant low. In advanced mode internally/ externally triggered or gated burst, the logical strobe signal provides a signal indicating the duration of a burst. The rising edge of the logical strobe signal is synchronized to the start of the first waveform period in a burst. The falling edge is synchronized to the start of the last waveform period in the burst. In advanced mode sweep with the frequency marker off, the logical strobe signal is a pulse with half of the duration of the sweep. The strobe signal goes high at the beginning of the sweep. In advanced mode sweep with the frequency marker on, the logical strobe signal goes high at the beginning of the sweep and goes low at the marker frequency. In advanced mode internally/externally modulated (AM, FM, FSK, PM, PWM), the logical strobe signal is the analog modulation waveform. In pattern mode (block mode = On), the logical strobe signal goes high at the beginning of the pattern and goes low at the last bit of the pattern. Refer to the User Guide for more details.

28 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Digital Channel Addition If the instrument is equipped with two output channels, channel 2 can be added to channel 1 internally. The maximum output voltage of channel 1 remains unchanged. If channel addition is selected, channel 2 outputs the unchanged waveform of channel 2. Timing Characteristics External In timing characteristics 81150A 81160A Delay: External In to Main Out 1, 2 Fix delay Advance mode: off, burst Advanced mode: sweep Pattern mode: on Variable delay 1 Range Resolution Accuracy 366 ns typ. 350 ns typ. 406 ns typ. Independent for Out 1, Out 2 0 s to 1000 s2 1 ps, 6 digits ± 25 ps ± 50 ppm 404 ns typ. 404 ns typ. 404 ns typ. Independent for Out 1, Out 2 0 s to 1000 s2 1 ps, 6 digits ± 35 ps ± 50 ppm Delay Fix delay Advanced mode: off, burst Advanced mode: sweep Pattern mode: on External In to Trigger Out 1, 2 366 ns typ. 350 ns typ. 406 ns typ. External In to Sync Out A, B 404 ns typ. 404 ns typ. 404 ns typ. Jitter 3 External In to Main Out 1, 2 External In to Trigger Out 1, 2 External In to Strobe Out 1, 2 External In to Sync Out A, B 15 ps RMS typ. 15 ps RMS typ. 15 ps RMS typ. 15 ps RMS typ. 15 ps RMS typ. 1. Not available, if sweep or modulation is selected 2. Trigger period ≥ variable delay 3. External In amplitude > 500 mV. External In transition time < 10 ns. Valid for externally triggered pulse, square, sine, ramp, arb. Externally triggered noise or externally triggered sweep has peak-peak jitter of 8 ns for the 81150A and 3.2 ns for the 81160A, measured with 50 Ω source impedance at main output. Channel 1 Channel 1 XORDelay, width Delay, width Data Data Channel 2 Channel 2 Channel 1 + Channel 1 + Channel 1 Channel 2 Channel 2

29 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Continuous or internally triggered timing characteristics 81150A 81160A Delay Fix delay Variable delay Out 1, 2 1 Range in continuous mode 2 Range in internally triggered mode 3 Resolution Accuracy Trigger Out 1, 2 to Main Out 1, 2 0 ns typ. Independent for Out 1, Out 2 0 to 1 waveform period 0 s to 1000 s typ. 1 ps, 6 digits ± 25 ps ± 50 ppm Sync Out A, B to Main Out 1, 2 0 ns typ. Independent for Out 1, Out 2 0 to 1 waveform period 0 s to 1000 s spec. 1 ps, 6 digits ± 35 ps ± 50 ppm Delay Advanced mode: burst Trigger Out 1, 2 to Strobe Out 1, 2 0 ns typ. Sync Out A to Sync Out B 0 ns typ. Jitter4 Jitter Main Out 1, 2 to Main Out 1, 2: 7 ps RMS typ. Trigger Out 1, 2 to Main Out 1, 2: 8 ps RMS typ. Trigger Out 1, 2 to Strobe Out 1, 2: 9 ps RMS typ. Trigger Out 1, 2 to Trigger Out 1, 2: 9 ps RMS typ. Jitter Main Out 1, 2 to Main Out 1, 2: 7 ps RMS typ. Sync Out A, B to Main Out 1, 2: 8 ps RMS typ. Sync Out A to Sync Out B: 9 ps RMS typ. 1. Not available, if sweep or modulation is selected. 2. Advanced mode = off or advanced mode = burst. 3. Trigger period ≥ variable delay. 4. Measured with 50 Ω source impedance at Main Out. Valid for continuous or internally triggered pulse, square, sine, ramp, arb. Internally triggered or continuous noise or sweep has peak-peak jitter of 8 ns typ. for the 81150A and 3.2 ns for the 81160A. Coupled mode On timing characteristics 81150A 81160A Delay: Main Out 1 to Main Out 2 Fix delay Variable delay Out 1, 2 5 Range in continuous mode 6 Range in internally triggered mode 7 Resolution Accuracy 0 ns typ. Independent for Out 1, Out 2 0 to 1 waveform period 0 s to 1000 s typ. 1 ps, 6 digits ± 25 ps ± 50 ppm 0 ns typ. Independent for Out 1, Out 2 0 to 1 waveform period 0 s to 1000 s spec. 1 ps, 6 digits ± 35 ps ± 50 ppm 5. Not available, if sweep or modulation is selected. 6. Advanced mode = off or advanced mode = burst. 7. Trigger period ≥ variable delay.

30 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Pattern generator (optional) 81150A Option PAT 81160A Option 330 81160A Option 660 Data rate 1 μbit/s to 120 Mbit/s (with internal pattern source) 1 µbit/s to 330 Mbit/s 1 µbit/s to 660 Mbit/s Pattern memory 16 Mbit with 1 bit resolution 4 Mbit for 1-channel instrument

2 Mbit per channel for 2-channel instrument

1 bit 1 bit for data rate 1 μbit/s to 330 Mbit/s 2 bits for data rate 330 Mbit/s to 660 Mbit/s Number of levels 2, 3, or 4 (user selectable) Sequencing Preamble followed by one looped data block-loop count: 1 – 10,000,000 the whole sequence can loop indefinitely or triggered Trigger modes Continuous, gated, one bit per trigger event, one sequence per trigger event Pattern sources Internal: PRBS –7, 9, 11, 15, 23, and 31 User-defined External: Pass through pattern mode. Pattern is applied and sampled at Modulation In. Indefinite pattern length. Up to 10 Mbit/s. Selectable automatic sampling for asynchronous operation or fix sampling for synchronous operation External sampling Automatic and fix Pattern modulation AM, FM, PM Arbitrary bit shapes User-defined and predefined bit transitions with up to 64 arbitrary waveform points per bit transition

31 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Download Times Block transfer is the fastest way to download waveforms to both the Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators. Download times: block transfer (meas.) 81150A 81160A USB 2.0 GPIB LAN USB 2.0 GPIB LAN Download times: integer comma separated values (meas.) 81150A 81160A USB 2.0 GPIB LAN USB 2.0 GPIB LAN Download times: float comma separated values (meas.) 81150A 81160A USB 2.0 GPIB LAN USB 2.0 GPIB LAN

32 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet General Specifications 81150A 81160A Power supply 100 V to 240 V ~, 50 to 60 Hz

100 V to 127 V ~, 50 to 400 Hz

100 V to 240 V ~, 50 to 60 Hz

Power consumption 110 W nom. 90 W nom. Operating temperature 0 to 50 ºC 0 to 55 ºC Operating altitude Up to 2000 m Up to 2000 m Storage temp. –40 to 70 °C –40 to 70 °C Stored states 4 named user configurations and factory default 4 named user configurations and factory default Power on state Default or last state Default or last state Interface 2 x USB 2.0 standard A, 1 x USB 2.0 standard B, GPIB and LAN 2 x USB 2.0 standard A, 1 x USB 2.0 standard B, GPIB and LAN Programming language SCPI-1997 IEEE-488.2 LXI compliant to LXI class C (rev. 1.1) SCPI-1997 IEEE-488.2 LXI compliant to LXI class C (rev. 1.1) Dimensions (WxHxD) Bench top Rack mount 439 mm x 108 mm x 456 mm 428 mm x 89 mm x 439 mm 439 mm x 108 mm x 456 mm 428 mm x 89 mm x 439 mm Weight 8 kg 8 kg Safety designed to IEC61010-1 UL61010 CSA22.2 61010.1 certified IEC61010-1 UL61010 CSA22.2 61010.1 certified EMC tested to IEC61326 IEC61326 Warm up time 30 min. 30 min. Calibration interval 2 years recommended 2 years recommended Warranty 3-year standard 3-year standard Cooling requirements When operating the instrument choose a location that provides at least 80 mm of clearance at rear, and at least 30mm of clearance at each side When operating the instrument choose a location that provides at least 80 mm of clearance at rear, and at least 30mm of clearance at each side Definitions Specification (spec.) The warranted performance of a calibrated instrument that has been stored for a minimum of 2 hours within the operating temperature range of 0 °C to 55 °C and after a 45-minute warm up period. Within ± 10 °C after autocal. All specifications include measurement uncertainty and were created in compliance with ISO-17025 and Z540 methods. Data published in this document are specifications (spec.) only where specifically indicated. Typical (typ.) The characteristic performance, which 80% or more of manufactured instruments will meet. This data is not warranted, does not include measurement uncertainty, and is valid only at room temperature (approximately 23 °C). Nominal (nom.) The mean or average characteristic performance, or the value of an attribute that is determined by design such as a connector type, physical dimension, or operating speed. This data is not warranted and is measured at room temperature (approximately 23 °C). Measured (meas.) An attribute measured during development for purposes of communicating the expected performance. This data is not warranted and is measured at room temperature (approximately 23 °C). Accuracy Represents the traceable accuracy of a specified parameter. Includes measurement error and timebase error, and calibration source uncertainty.

33 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Available Modes of Operation Continuous 81150A and 81160A Pulse Square Sine Ramp Noise Arb DC Advanced mode: off Y Y Y Y Y Y Y Advanced mode: burst Y Y Y Y N Y N Advanced mode: modulation AM N Y Y Y N Y N FM N Y Y Y N Y N PM N Y Y Y N Y N FSK N Y Y Y N Y N PWM Y N N N N N N Advanced mode: sweep N Y Y Y N Y N Internally triggered or externally triggered 81150A and 81160A Pulse Square Sine Ramp Noise Arb DC Advanced mode: off Y Y Y Y Y Y N Advanced mode: burst Y Y Y Y N Y N Advanced mode: modulation AM N N N N N N N FM N N N N N N N PM N N N N N N N FSK N N N N N N N PWM N N N N N N N Advanced mode: sweep N Y Y Y N Y N Gated 81150A and 81160A Pulse Square Sine Ramp Noise Arb DC Advanced mode: off Y Y Y Y Y Y N Advanced mode: burst Y Y Y Y N Y N Advanced mode: modulation AM N N N N N N N FM N N N N N N N PM N N N N N N N FSK N N N N N N N PWM N N N N N N N Advanced mode: sweep N Y Y Y N Y N

34 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Ordering Information for Keysight 81150A #001 1-channel pulse function arbitrary noise generator #002 2-channel pulse function arbitrary noise generator #1A7 ISO17025 calibration documents #Z54 Z540.3 calibration documents #PAT License for 120 Mbit/s pattern generator Accessories included – Certificate of calibration – Local power cord – USB cable – Product CD (User Guide, Getting Started Guide, IVI-COM driver, examples for remote access) Optional accessories #DOC Printed documentation. Includes printed Getting Started Guide and printed User Guide #1CP Rack mount kit #R-51B-001-5Z Additional 2 years warranty (5 years total) Upgrades for 81150A, 81150AU #PAT License for pattern generator #DOC Printed documentation #EHD Fixture for 100 Mbit Ethernet and HDMI 1.4

35 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet Literature title Publication number Pulse Pattern and Data Generators, Brochure 5980-0489E 81150A and 81160A Pulse Function Arbitrary Noise Generator, Demo Guide 5989-7718EN 81150A Pulse Function Arbitrary Noise Generator, Flyer 5989-7720EN 81150A and 81160A Pulse Function Arbitrary Noise Generator, Application Booklet 5989-7860EN 81150A Quick Fact Sheet 5990-4565EN 81160A Quick Fact Sheet 5990-6984EN 33503A BenchLink Waveform Builder Pro Software, Data Sheet 5990-7569EN For the latest version of this document, please visit our website at: www.keysight.com/find/81150 www.keysight.com/find/81160 and go to the Product Library. Ordering Information for Keysight 81160A #001 1-channel pulse function arbitrary noise generator #002 2-channel pulse function arbitrary noise generator #1A7 ISO17025 calibration documents #Z54 Z540.3 calibration documents #330 License for 330 Mbit/s pattern generator #660 License for 660 Mbit/s pattern generator Accessories included – Certificate of calibration – Local power cord – USB cable – Product CD (User Guide, Getting Started Guide, IVI-COM driver, examples for remote access) Optional accessories #DOC Printed documentation. Includes printed Getting Started Guide and printed User Guide #1CP Rack mount kit #R-51B-001-5Z Additional 2 years warranty (5 years total) Upgrades for 81160A, 81160AU #330 License for 330 Mbit/s pattern generator #660 License for 660 Mbit/s pattern generator #326 License for upgrade from 330 Mbit/s to 660 Mbit/s pattern generator #DOC Printed documentation

36 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators – Data Sheet This information is subject to change without notice. © Keysight Technologies, 2011 - 2016 Published in USA, August 31, 2016 5989-6433EN www.keysight.com myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. KEYSIGHT SERVICES Keysight Services www.keysight.com/find/service Our deep offering in design, test, and measurement services deploys an industry-leading array of people, processes, and tools. The result? We help you implement new technologies and engineer improved processes that lower costs. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. www.keysight.com/find/81150 www.keysight.com/find/81160 Evolving Our unique combination of hardware, software, support, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-06-08-16) DEKRA Certified ISO9001 Quality Management System www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System