U4421A MIPI® D-PHY™ Protocol Exerciser/Analyzer Data Sheet
02 | Keysight | U4421A MIPI® D-PHY™ Protocol Exerciser/Analyzer - Data Sheet The MIPI D-PHY Analyzer, Two Instruments in 0ne (Available with Option 601 or 603) Any number of filters and views can be applied. Organize them easily in the overview GUI Link multiple windows together or track correlated events with markers Isolate any packet’s header See data as a packet payload or as individual lanes Raw Mode lets you see the “why” behind your protocol Get the “big picture” with the Overview tab Quickly customize simple drag-and-drop trigger macros Use advanced if-then-else triggers to branch in any direction to up to eight different conditions. Add counters, timers, and flags for even more control
03 | Keysight | U4421A MIPI® D-PHY™ Protocol Exerciser/Analyzer - Data Sheet The MIPI D-PHY Analyzer, Two Instruments in 0ne (Available with Option 601 or 603) (continued) The U4421A MIPI D-PHY Analyzer option for CSI-2 and DSI gives you deep insight into your mobile computing designs Time correlate multiple busses and views. Multiple modules (D-PHY, PCI, DDR, high-speed logic, and HDMI) can be installed in one mainframe, and multiple frames can be connected. Any number of filters and views can be applied. Organize them easily in the overview GUI. Link multiple windows together or track correlated events with markers. Look deeply into packets with “peel off” tabs. Isolate any packet’s header, or data as a packet payload or individual lanes. Raw Mode lets you see the “why” behind your protocol. Raw state data that is acquired by the analyzer can be displayed as a time-correlated waveform view. Get the “big picture” with the Overview tab. Get a count of the various types of traffic in any period of time, including errors; then step through each occurrence with embedded navigation tools. Isolate events with protocol-aware triggers. Simple drag-and-drop trigger macros can be quickly customized. Or use advanced if-then-else triggers to branch in any direction to up to eight different conditions. Trigger on packet types, errors or into payload data. Probe any system with three flexible probing options (below). The E5381A differential flying leads let you connect to vias, headers, and traces. The E5404A Soft Touch Pro probe gives you a rugged in-board connection to a small footprint. In addition, UNH-IOL has created an SMA to Soft Touch break-out board that connects directly to their Reference Termination Board, or be used as a generic mid-bus adapter. Key features: –Protocol aware for DSI and CSI-2 traffic in all views, triggers, and filters –Up to 1.5 Gb data rate – Up to 16 GB Trace Depth –Up to 4 data lanes + CLK –5-ns resolution raw mode data – N-way trigger branching – Integrated image extraction software Target users: Designers and validators of –Mobile devices – Mobile embedded systems –MIPI silicon/IP – Cameras
04 | Keysight | U4421A MIPI® D-PHY™ Protocol Exerciser/Analyzer - Data Sheet The MIPI D-PHY Analyzer, Two Instruments in 0ne (Available with Option 601 or 603) (continued) The U4421A MIPI D-PHY Analyzer option for CSI-2 and DSI gives you deep insight into your mobile computing designs (continued) ... analyze and extract the transmitted images by physically probing or using the analyzer's internal loopback. Adjust timing parameters, including data rate, output voltage, skew rate, signal timing, and lane skew. End-to-end data path analysis: Quickly create exerciser traffic ...
05 | Keysight | U4421A MIPI® D-PHY™ Protocol Exerciser/Analyzer - Data Sheet The MIPI D-PHY Analyzer, Two Instruments in 0ne (Available with Option 601 or 603) (continued) The U4421A MIPI D-PHY Analyzer option for CSI-2 and DSI gives you deep insight into your mobile computing designs (continued) The U4421A MIPI D-PHY Exerciser option for CSI-2 and DSI provides the record depth necessary to stimulate designs with high-definition images and video. It also lets you simulate traffic from a wide variety of devices busses of varying signal performance. Deep memory. With 1GB of standard memory, and with options for 4 GB and 16 GB, you can generate long sequences of high definition images and videos. Internal loopback, available with the U4421A analyzer Options 601 and 603, lets you verify the exerciser’s output. This gives you additional confidence in the data that you are sending to your target. Change both HP and LP signal levels to understand how your system reacts to dimin - ished signal voltages. A system that can tolerate lower signal swings will usually have a longer battery life. Change signal data rate, slew rate, and lane timing to get insight into how your systems and peripherals react to a wide variety of CSI and DSI signals. Bring the “plug-fest” experience to your bench. Generate traffic quickly with your own CSV files, the integrated packet inserter or the optional image inserter software. Recall your favorite patterns with user-defined “hot” (shortcut) keys. Each module can simultaneously be an exerciser and an analyzer. Combine multiple modules in a 2 (M9502A) or 5 (M9505A) slot AXIe mainframe to analyze and simulate cross-system behavior. Key features: –Generate user-defined D-PHY traffic –Up to 1.5 GB data rate –Up to 16 GB trace depth –Change speed, slew rate, volt - age levels and lane skew –Flexible pattern creation – GUI – Packet inserter – Image inserter Target users: Designers and validators of –Mobile devices –Mobile embedded systems –MIPI silicon/IP –Displays
06 | Keysight | U4421A MIPI® D-PHY™ Protocol Exerciser/Analyzer - Data Sheet Keysight U4421A – Analyzer Option (601) Performance Characteristics Electrical HSV minimum differential 100 mV LPV threshold range 0 to 1.5 V Lane width Up to 4 with Option 004. Analyze 1-, 2-, 3-, or 4-lane systems Performance Maximum bit rate (high-speed mode) 1.5 Gbps Minimum bit rate (high-speed mode) 80 Mbps Maximum bit rate (low-power mode) 10 Mbps Minimum bit rate (low-power mode) N/A Raw mode LP sample resolution 5 ns, typical for LP traffic; 1 ÷ bit rate for HS traffic Maximum data rate of probes E5381A E5405A 1.5 Gbps with 82 Ω coaxial resistor adapter, 1.0 Gbs with damped wire and 3-pin header adapters.
1.5 Gbps
Memory User allocated (shared among exerciser, analyzer and raw mode) Standard Option M04 (recommended for images) Option M16 (recommended for video) 1 GB 4 GB 16 GB Protocol Protocol version support Display Display Serial Interface (DSI) v1.1 Display Serial Interface (DSI) v1.02.00 Display Serial Interface Version 1.01.00 Display Command Set (DCS) v1.1 Display Command Set (DCS) v1.02.00 Display Command Set v1.01.00 Stereoscopic Display Formats (SDF) v1.0 Camera (CSI-2) Camera Serial Interface 2 v1.01.00 Camera Serial Interface 2 v1.00 (CSI-2) Protocol viewer Hierarchical packet-level display Protocol views Packets, header, lanes, payload, and traffic overview Protocol decoder Simultaneous HS and LP data support Short and long packet decode CSI-2 and DSI-1 decode Waveform view (Raw Mode) Yes Yes Yes, user selectable Packets and lanes Error display SOT error display EOT error display Escape error display Sequence error display Turnaround error display ECC, CRC error display Contention detection Yes Yes Yes Yes Yes Yes No Track changes in speed (HS/LP) mode Yes Correlation markers > 1,000 user-defined Marker measurements Yes, user-defined time and count measurements Window correlation lock Yes, user-defined
07 | Keysight | U4421A MIPI® D-PHY™ Protocol Exerciser/Analyzer - Data Sheet Keysight U4421A – Analyzer Option (601) Performance Characteristics (Continued) Triggering capabilities Trigger on protocol commands Yes, with > 130 macros Simple trigger Drag and drop Advanced trigger Sequence levels Logical branching Up to 8 N-way Trigger on protocol patterns Yes, on both DSI and CSI long and short packet headers Protocol pattern customization Yes, with bit-level editing Payload pattern matcher Event counter Time counter First 4 bytes Yes Yes, 100 ns accuracy Real-time error detection 5 ns resolution ± 5 ns of accuracy SOT error trigger EOT error trigger Escape error trigger Sequence error trigger Turnaround error trigger ECC CRC Yes, on a per lane basis Yes, on a per lane basis Yes, on a per lane basis Yes, on a per lane basis Yes, on a per lane basis Yes Yes Display Low power state of data transmission All escape mode actions, except ultra-low power Stopped No Image extractor / Image inserter DSI Burst mode Packed pixel stream, 16-bit RGB, 5-6-5 format Packed pixel stream, 18-bit RGB, 6-6-6 format Loosely packed pixel stream, 18-bit RGB, 6-6-6 format Packed pixel stream, 24-bit RGB, 8-8-8 format Packed pixel stream, 30-bit RGB, 10-10-10 format Packed pixel stream, 36-bit RGB, 12-12-12 format Packed pixel stream, 12-bit YCbCr, 4:2:0 format Packed pixel stream, 16-bit YCbCr, 4:2:2 format Loosely packed pixel stream, 20-bit YCbCr, 4:2:2 format Packed pixel stream, 24-bit YCbCr, 4:2:2 Format Non-burst mode Packed pixel stream, 16-bit RGB, 5-6-5 format Packed pixel stream, 18-bit RGB, 6-6-6 format Loosely packed pixel stream, 18-bit RGB, 6-6-6 format Packed pixel stream, 24-bit RGB, 8-8-8 format Packed pixel stream, 30-bit RGB, 10-10-10 format Packed pixel stream, 36-bit RGB, 12-12-12 format Packed pixel stream, 12-bit YCbCr, 4:2:0 format Packed pixel stream, 16-bit YCbCr, 4:2:2 format Loosely packed pixel stream, 20-bit YCbCr, 4:2:2 format Packed pixel stream, 24-bit YCbCr, 4:2:2 format Command mode 3 bits per pixel 8 bits per pixel 12 bits per pixel 16 bits per pixel 18 bits per pixel 24 bits per pixel
08 | Keysight | U4421A MIPI® D-PHY™ Protocol Exerciser/Analyzer - Data Sheet Keysight U4421A – Analyzer Option (601) Performance Characteristics (Continued) Image extractor / Image inserter (Continued) CSI RGB444 RGB555 RGB565 RGB666 RGB888 YUV420 8-bit YUV420 8-bit (Chroma shifted pixel sampling) legacy YUV420 8-bit YUV420 10-bit YUV420 10-bit (Chroma shifted pixel sampling) YUV422 8-bit YUV422 10-bit RAW6 RAW7 RAW8 RAW10 RAW12 RAW14
09 | Keysight | U4421A MIPI® D-PHY™ Protocol Exerciser/Analyzer - Data Sheet Keysight U4421A – Analyzer Option (602) Performance Characteristics Electrical Features Lane width Up to 4 with Option 404. Exercise 1-, 2-, 3-, or 4-lane systems Low-power voltage high adjustment 500 mV to 1.5 V Low-power voltage low adjustment ± 100 mV High-speed output differential voltage 60 mV to 320 mV High-speed common mode voltage 60 mV to 380 mV Output driving impedance High-speed: 50 Ω; Low-power: 82.4 Ω Bus termination modes Open, dynamic, static 100 Ω differential Waveform timing control Yes, automatic or manual settings CLK-POST timing control Yes, automatic or manual settings CLK-PRE timing control Yes, automatic or manual settings CLK-PREPARE timing control Yes, automatic or manual settings CLK-TRAIL timing control Yes, automatic or manual settings CLK-ZERO timing control Yes, automatic or manual settings HS-EXIT timing control Yes, automatic or manual settings HS-PREPARE Yes, automatic or manual settings HS-ZERO Yes, automatic or manual settings HS-TRAIL Yes, automatic or manual settings LPX Yes, automatic or manual settings TA_Get Yes, automatic or manual settings TA_GO Yes, automatic or manual settings CLK lane and data lane skew adjust 5 ps, resolution typical; ± 0.5 UI @ 1 GB and above Reference clock input Required, Clock input = 1/10 bit rate to 700 Mbs, 1/20 above 700 MB Performance Maximum bit rate (high-speed mode) 1.5 Gbps Minimum bit rate (high-speed mode) 80 Mbps Maximum bit rate (low-power mode) 10 Mbps Minimum bit rate (low-power mode) 800 Kbps Memory User allocated (shared among Exerciser, Analyzer and Raw Mode) Standard 1 GB Option M04 (recommended for images) 4 GB Option M16 (recommended for video) 16 GB Packet insertion HSDT request error generation Yes, with timing control to violate specs SOT synch error generation No Endof HSDT error generation Yes, with timing control to violate specs LPD transmission error generation Yes, with waveform timing control and direct control of data transmitted on the link Protocol errors Yes Turnaround error generation No (does not operate in slave mode) ECC, CRC error generation Manual
10 | Keysight | U4421A MIPI® D-PHY™ Protocol Exerciser/Analyzer - Data Sheet Keysight U4421A – Analyzer Option (602) Performance Characteristics (Continued) Environmental specifications Radiated emissions (RE) CISPR 11/EN55001 Group 1 Class A Radiated immunity (RI) EN/IEC 61000-4-3 frequency range @ V/m 80 MHz to 2 GHz @ 3 V/m; 2 GHz to 2.7 GHz @1 V/m Electrostatic discharge (EN/IEC 61000-4-2)+ discharge air/contact (kV) 15/8 Operating temperature Operating range: Min-max (°C) +5 ±40 Storage temperature Storage range: Non-operating min-max (°C) –40 ±70 Operating humidity max % RH @ temperature °C 80 @ 40 Storage humidity max % RH @ temperature °C 90 @ 65 Random vibration, Operating 5 to 500 Hz random, Grms 0.21 Random vibration, Survival 5 to 500 Hz random, Grms 2.09 Half sine shock 2 mS half sine delta velocity m/sec (in/sec) 1.6 (63) Trapezoidal shock 24 mS trapezoidal delta velocity m/sec (in/sec) 8.00 (315) Operating altitude (kilo feet/kilo meters) 10/3.1 Storage altitude Non-operating (kilo feet/kilo meters) 15/4.6 Operating magnetic field immunity A/m rms 30 Safety IEC 61010-1 Single fault condition
11 | Keysight | U4421A MIPI® D-PHY™ Protocol Exerciser/Analyzer - Data Sheet Module Configuration Select Instrument type(s) Analyzer only (601) Exerciser only (602) U4421A exerciser/analyzer Exerciser Analyzer (603) Select lane count 1-lane (default) 2-lanes (402) Select protocol(s) CSI-2 (701) DSI-1 (702) CSI-2 + DSI-1 (703) Select memory 1 GB (default) 4 GB (M04) Select Image analysis Image extractor (001) requires 601 or 603 Image inserter (003) requires 602 or 603 16 GB (M16) 4-lanes (404)
12 | Keysight | U4421A MIPI® D-PHY™ Protocol Exerciser/Analyzer - Data Sheet Chassis and Probing Configuration Chassis option M9502A 2-slots M9505A 5-slots PC control options M9536A Embedded PC module (no cables or adapters needed) Connecting via PCIe ® to a Desktop PC M9048A PCIe desktop adapter Y1202A PCIe cable (x8 to x8) Connecting via PCIe to a Laptop PC M9045B ExpressCard adapter Y1200B PCIe cable (x1 to x8) Analyzer probes (with Options 601 or 603) N2815A REQUIRED (Logic cable) Pick one or more of the following E5381A Flying lead adapter E5405A Soft touch adapter SMA breakout to soft touch adapter (available from UNH-IOL) Exerciser probe (with Options 602 or 603) U4422A SMA cable, MIPI D-PHY, 13 leads/1.5 Gbps
13 | Keysight | U4421A MIPI® D-PHY™ Protocol Exerciser/Analyzer - Data Sheet Keysight software is downloadable expertise. From first simulation through first customer shipment, we deliver the tools your team needs to accelerate from data to information to actionable insight. Learn more at www.keysight.com/find/software Start with a 30-day free trial. www.keysight.com/find/free_trials –Electronic design automation (EDA) software –Application software –Programming environments – Utility software Keysight software is downloadable expertise. From first simulation through first customer shipment, we deliver the tools your team needs to accelerate from data to information to actionable insight. Learn more at www.keysight.com/find/software Start with a 30-day free trial. www.keysight.com/find/free_trials –Electronic design automation (EDA) software –Application software –Programming environments – Utility software Download your next insight Keysight software is downloadable expertise. From first simulation through first customer shipment, we deliver the tools your team needs to accelerate from data to information to actionable insight. Learn more at www.keysight.com/find/software Start with a 30-day free trial. www.keysight.com/find/free_trials –Electronic design automation (EDA) software –Application software –Programming environments – Utility software Download your next insight
www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA ®, AdvancedTCA®, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. 14 | Keysight | U4421A MIPI® D-PHY™ Protocol Exerciser/Analyzer - Data Sheet
www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a full one-year warranty on all accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. Keysight Infoline www.keysight.com/find/service Keysight’s insight to best in class information management. Free access to your Keysight equipment company reports and e-library. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. MIPI® and M-PHY ® are registered trademarks owned by the MIPI Alliance. D-PHY™ is a trademark of the MIPI Alliance. PCI-SIG ®, PCIe ® and the PCI Express ® are US registered trademarks and/or service marks of PCI-SIG. From Hewlett-Packard through Agilent to Keysight For more than 75 years, we‘ve been helping you unlock measurement insights. Our unique combination of hardware, software and people can help you reach your next breakthrough. Unlocking measurement insights since 1939.
1939 THE FUTURE
For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-07-24-15) www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System 15 | Keysight | U4421A MIPI® D-PHY™ Protocol Exerciser/Analyzer - Data Sheet This information is subject to change without notice. © Keysight Technologies, 2013 - 2015 Published in USA, September 29, 2015 5991-0488EN www.keysight.com