U2702A KEYSIGHT | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 12

Technical content

Features

– 100 MHz and 200 MHz bandwidths – Up to 1 GSa/s maximum sample rate – 32 Mpts of waveform memory – Compact and portable size – Advanced triggering, including edge, pulse width and TV – Four math functions, including FFTs standard – Dual-play function – standalone and modular capability – Compatibility with High-Speed USB 2.0 and USBTMC-USB488 standards The Keysight Technologies, Inc. U2701A and U2702A USB modular oscilloscopes combine a set of essential features that are ideal for analyzing designs in an affordable way. The U2701A and U2702A come in two bandwidths: 100 MHz and 200 MHz respectively. These devices are uniquely designed to accommodate your need for flexibility with the dual-play function. This function allows you to use the oscilloscope as a standalone instrument, or to scale up the test system in a cardcage with additional scopes or with other Keysight USB modular product offerings, providing a complete solution for system development. The U2701A/U2702A USB modular oscilloscopes give you the debugging power you need. Each USB modular oscilloscope comes with standard features such as advanced triggering, automatic measurements, math functions including FTTs and much more. Introduction

Figure 1. The dual-play capability allows the U2701A/U2702A USB modular oscilloscope to be used as a standalone unit or as part of test system in a cardcage. ideal for the education, design validation and manufacturing industries. higher test and analysis result accuracy.

division, and Fast Fourier Transform (FFT). Figure 2. The U2701A and U2702A connect to the computer or laptop with a USB cable, enabling fast fast-sampling capability allows you to perform intermittent detections easily. Pulse triggering allows you to trigger on pulse events. carried to and around your work field. Every U2701A and U2702A comes with a three year warranty.

117.0 0 mm 180.00 mm 15.00 mm Product characteristics and general specifications REMOTE INTERFACE – Hi-Speed USB 2.0 – USBTMC 488.2 Class device 1 POWER CONSUMPTION – +12 VDC, 2 A – Installation Category III OPERATING ENVIRONMENT – Operating temperature from 0 °C to +50 °C – Operating humidity at 20% to 85% RH (non-condensing) – Altitude up to 2000 meters – Pollution Degree 2 – For indoor use only STORAGE COMPLIANCE – Storage temperature from –20 °C to 70 °C – Storage humidity at 5% to 90% RH (non-condensing) SAFETY COMPLIANCE Certified with: – IEC 61010-1:2001/EN 61010-1:2001 (2nd Edition) – USA: UL61010-1: 2004 – Canada: CSA C22.2 No.61010-1:2004 EMC COMPLIANCE – IEC 61326-1:2002/EN 61326-1:1998+A2:2001+A3:2003 – Canada: ICES-001:2004 – Australia/New Zealand: AS/NZS CISPR 11:2004 SHOCK AND VIBRATION Tested to IEC/EN 60068-2 IO CONNECTOR BNC connector DIMENSION (W × D × H) Module dimension: – 117.00 mm × 180.00 mm × 41.00 mm (with bumpers) – 105.00 mm × 175.00 mm × 25.00 mm (without bumpers) WEIGHT – 534 g (with bumpers) – 482 g (without bumpers) WARRANTY Three years for U2701A/U2702A Three months for standard shipped accessories Product outlook and dimensions Front view Standard shipped accessories – 12 V, 2 A AC/DC Power adapter – Power cord – USB Standard A to Mini-B interface cable – 2 x 10:1 Passive probe 150 MHz 1.2m, N2862A (only applicable for U2701A) – 2 x 10:1 Passive probe 300 MHz 1.2m, N2863A (only applicable for U2702A) – L-Mount kit (used with modular product chassis) – Keysight Automation-Ready CD-ROM (contains the Keysight IO Libraries Suite) – Keysight USB Modular Products Quick Start Guide – Keysight USB Modular Products Reference CD-ROM – Keysight USB Modular Products Quick Reference Card – Certificate of Calibration 41.00 mm Optional accessories – BNC cable, U2921A-100 – USB Secure cable, U2921A-101 – 1:1 Passive probe 20 MHz, 1.5 m, 10070C (Order no.: U2701A-200) – 10:1 Passive probe 150 MHz 1.2m, N2862A (only applicable for U2701A) – 10:1 Passive probe 300 MHz 1.2m, N2863A (only applicable for U2702A) 1. Compatible with Microsoft Windows operating systems only. Requires a direct USB connection to the PC so the appropriate driver can be installed in the USB modular instrument. 5 | Keysight | U2701A/U2702A USB Modular Oscilloscope - Data Sheet

Performance specifications1 Vertical system: oscilloscope channels Bandwidth (–3 dB) U2701A: DC to 100 MHz U2702A: DC to 200 MHz Scope channel triggering Trigger sensitivity < 10 mV/div: greater of 1 div or 5mV; ≥ 10 mV/div: 0.6 div Performance characteristics2 Acquisition: oscilloscope channels Real time sample rate – 2 channels interleaved – Each channel

1 GSa/s

500 MSa/s

– 2 channels interleaved – Each channel Normal Single-shot

32 Mpts 64 Mpts

16 Mpts 32 Mpts

Vertical resolution 8 bits Peak detection Yes Averaging Any number from 1 to 999 Filter Sin(x)/x interpolation for time base 1 ns to 100 ns Sweep modes Auto, normal, single Vertical system: oscilloscope channels Scope channels U2701A/U2702A: Ch 1 and Ch 2 simultaneous acquisition AC coupled U2701A: 3.5 Hz to 100 MHz U2702A: 3.5 Hz to 200 MHz Calculated rise time (= 0.35/bandwidth) U2701A: 3.5 ns U2702A: 1.75 ns Single-shot bandwidth U2701A: 100 MHz U2702A: 200 MHz Range 2 mV/div to 5 V/div (1 MΩ) Maximum input 3 CAT I 30 Vrms, 42 Vpk Offset range ±4 div Example: ±8 mV on 2 mV/div; ±20 V on 5 V/div Dynamic range ±4 div Input impedance 1 MΩ: ≈ 16 pF Coupling AC, DC, Ground BW limit ≈ 25 MHz Standard probes 10:1 Passive probe 150 MHz 1.2 m 10:1 Passive probe 300 MHz 1.2 m ESD tolerance ±2 kV Noise peak-to-peak 3 mVpp DC vertical offset accuracy ≤ 200 mV/div: ±0.1 div ±2.0 mV ±0.5% offset value; > 200 mV/div: ±0.1 div ±2.0 mV ±1.5% offset value DC vertical gain accuracy ±4.0% of full scale 1. All specifications are warranted. specifications are valid after a 30-minute warm-up and within ±100 ºC of last calibration temperature. 2. All characteristics are typical performance values and are not warranted. Characteristics are valid after a 30-minute warm-up period and within ±10 ºC of last calibration temperature. 3. Under standalone use, you are only allowed to measure up to CAT I 30 Vrms. For high-voltage measurement up to CAT I 300 Vrms, you must install the L- Mount kit on the U2701A/U2702A before plugging it into the product chassis. Ensure that the L-Mount kit installed on your modular oscilloscope is screwed to the product chassis to ensure proper chassis grounding. Note that you are required to use the provided 10:1 probes (N2862A/N2863A) for high-voltage measurements to avoid damaging your instrument. 6 | Keysight | U2701A/U2702A USB Modular Oscilloscope - Data Sheet

Performance characteristics1 (continued) Vertical system: oscilloscope channels (continued) Single-cursor accuracy ±{DC vertical gain accuracy + DC vertical offset accuracy + 0.2% full scale (~1/2 LSB)} Example: For 50 mV signal, scope set to 10 mV/div (80 mV full scale), 5 mV offset, = ±6.385 mV Dual-cursor accuracy ±{DC vertical gain accuracy + 0.4% full scale (~1 LSB)} Example: For 50 mV signal, scope set to 10 mV/div (80 mV full scale), 5 mV offset, Accuracy = ±{4.0% (80 mV) + 0.4% (80 mV)} = ±3.52 mV Horizontal Range 1 ns/div to 50 s/div Time base accuracy 20 ppm Delay range Pre-trigger: –100 % Post-trigger: +100 % Modes Main, roll, XY XY Yes Reference position Center Trigger System Sources Ch 1, Ch 2, Ext (not applicable for TV trigger) Modes Normal, single, auto trigger Hold off time 60 ns Selections Edge, pulse width, TV – Edge Triggers on a rising or falling edge, alternating, or either edge of any source – Pulse width Triggers on a pulse width greater than, equal to, or less than a specified time limit, with time limits ranging from 16 ns to 10 s Minimum lower limit: 8 ns Minimum upper limit: 16 ns Maximum pulse width setting: 10 s – TV Triggers on one of three standard television waveforms: NTSC, PAL, SECAM TV trigger sensitivity: 0.6 division of sync signal. Modes supported include Field 1, Field 2, all fields, or any line within a field Autoscale Single-button automatic setup of all channels Oscilloscope channel triggering Range (internal) ±4 div from center screen Coupling AC (< 15 Hz) LF reject (~ 35 kHz) HF reject (~ 35 kHz) External (EXT) triggering Input impedance 1 MW: ≈ 16 pF Maximum input CAT I 30 Vrms, 42 Vpk Range DC coupling: trigger level ±1.25 V and ±2.5 V EXT trigger pulse width > 2.5 ns 1. All characteristics are typical performance values and are not warranted. Characteristics are valid after a 30-minute warm-up period and within ±10 ºC of last calibration temperature. 7 | Keysight | U2701A/U2702A USB Modular Oscilloscope - Data Sheet

Performance characteristics1 (continued) External (EXT) triggering (continued) Trigger level sensitivity For ±1.25 V range setting: DC to 100 MHz: 100 μV > 100 MHz: 200 μV For ±2.5 V range setting: DC to 100 MHz: 250 μV > 100 MHz: 500 μV Display Interpolation Sin(x)/x Display types Dots and vectors Persistence Off, infinite Format X Y, roll Measurement features Automatic measurements Measurements are continuously updated. Cursors track last selected measurement. Voltage Peak-to-peak, maximum, minimum, average, amplitude, top, base, Vrms, overshoot, preshoot, crest, standard deviation, cycle RMS, RMS AC Time Frequency, period, +width, –width, +duty cycle, –duty cycle, rise time, fall time, delay, phase Frequency Maximum peak Cursors – Modes: Manual – Type: Time, voltage and frequency (FFT) – Measurements: DT, DV, frequency, Peak Scan (FFT), DPeak Math functions Add, substract, multiply, FFT, divide FFT Points 1250 points (for 500 ns and above) Source of FFT Source channels 1 or 2 Window Hanning, Hamming, Blackman-Harris, Rectangular, Flattop Noise floor –50 dB to –90 dB depending on averaging Amplitude Display in dBV Maximum frequency 250 MHz 1. All specifications are warranted. specifications are valid after a 30-minute warm-up and within ±100 ºC of last calibration temperature. 8 | Keysight | U2701A/U2702A USB Modular Oscilloscope - Data Sheet

Keysight Measurement Manager The Keysight Measurement Man - ager (KMM) is an application data viewer software that comes with the standard purchase of the U2700A Series USB modular instruments. This software is designed to help you perform quick device configuration, data logging and data acquisition using the products. Supported features found in the U2701A/ U2702A USB modular oscilloscope: – Averaging – Command logger to allow the capture of configuration commands that can be easily converted to snippets of VEE, VB, C++ and C# code – Self-test – Self-calibration – Option to save the current instrument configuration to a file – Data logging and export feature to CSV, HTML and text only format files that can be printed – Trigger settings between modules in the instrument chassis with Star trigger and Master/Slave trigger Keysight Measurement Manager prerequisites Prior to installing the Keysight Measurement Manager software, ensure that your PC meets the following minimum system requirements for installation and operation. Requirement Windows XP operating systems Windows Vista operating systems Windows 7 operating systems Operating system Windows XP Service Pack 3 (or later) Windows Vista (32-bit) Service Pack 1 and 2 2 Windows 7 (32-bit and 64-bit) 3, 4 Processor speed

600 MHz or

higher required, 800 MHz recommended

1 GHz 32-bit (x86) 3 GHz 32-bit (x86)

256 MB minimum

(1 GB or greater recommended)

1 GB minimum 2 GB minimum

Hard-disk space 1.5 GB minimum 1.5 GB minimum 1.5 GB minimum Video Super VGA (800 × 600) 256 colors or more Support for DirectX 9 graphics with 128 MB graphics memory recommended 5 Support for DirectX 9 graphics with 128 MB graphics memory recommended CD-ROM drive or DVD-ROM drive

6 Required Required Required

Browser Microsoft Internet Explorer 5.01 or greater Microsoft Internet Explorer 7 or greater Microsoft Internet Explorer 7 or greater 1. Supported Windows XP editions — Home or Professional 2. Supported Windows Vista (32-bit) editions — Home Basic, Home Premium, Business, or Ultimate 3. Supported Windows 7 (32-bit and 64-bit) editions — Home Basic, Home Premium, Professional, Enterprise, or Ultimate 4. Keysight Measurement Manger for Windows 7 64-bit support is a 32-bit application running on a WOW64 (Windows-on-Windows 64-bit) emulator. 5. Super VGA graphics is supported for Windows Vista and Windows 7. 6. The type of media provided with the product determines whether a CD-ROM drive or DVD-ROM drive is required. Software requirements Keysight IO Libraries Suite 15.1 and above 1 Keysight T&M Toolkit Runtime version 2.12 Keysight T&M Toolkit Redistributable Package 2.1 patch 2 Microsoft .NET Framework version 2.02 1. Available on the Keysight Automation-Ready CD-ROM 2. Bundled with Keysight Measurement Manager software application installer 9 | Keysight | U2701A/U2702A USB Modular Oscilloscope - Data Sheet

Other products in the Keysight USB Modular Test Instruments Family U2722A/U2723A USB Modular Source Measure Unit Features: – Three-channel SMU with four-quadrant source/measure operation High measurement sensitivity of 100 pA with 16-bit resolution for all voltage and current ranges – 0.1% basic accuracy – Embedded test scripts (for U2723A) For more information: http://www.keysight.com/find/U2722A http://www.keysight.com/find/U2723A U2741A USB Modular Digital Multimeter (DMM) Features: – Fast reading speed (up to 100 Sa/s) – Wide range of basic measurement functions, including frequency and temperature measurements For more information: http://www.keysight.com/find/U2741A U2751A USB Modular Switch Matrix Features: – Minimal cross-talk of -30 dB at 45 MHz wide bandwidth – High bandwidth at 45 MHz without terminal block – Capability to test up to four devices-under-test (DUTs) – Works with other Keysight instruments for multi-point testing For more information: http://www.keysight.com/find/U2751A U2761A USB Modular Function/Arbitrary Waveform Generator Features: – Direct digital synthesis (DDS) waveform generator – Pulse generator that can generate pulse signal as stimulus – Easy customization with Arbitrary Waveform Editor – Internal modulation capability simplifies test setup For more information: http://www.keysight.com/find/U2761A U2781A USB Modular Product Chassis Features: – Expansion of channels for each modular product – Multiple instrument synchronization – Internal and external 10 MHz reference clock – High-speed USB 2.0 – SSI/Star trigger bus synchronization between external trigger source and modules For more information: http://www.keysight.com/find/U2781A 10 | Keysight | U2701A/U2702A USB Modular Oscilloscope - Data Sheet

Ordering Information

U2701A USB modular oscilloscope (100 MHz) U2702A USB modular oscilloscope (200 MHz) Optional accessories Model Description N2862A 10:1 pas sive probe, 150 MHz, 1.2 m (for U2701A) N2863A 10:1 passive probe, 300 MHz, 1.2 m (for U2702A) U2701A-200 10070C 1:1 passive probe, 20 MHz, 1.5 m U2921A-100 BNC cable, 1.2 m U2921A-101 USB secure cable, 2 m 11 | Keysight | U2701A/U2702A USB Modular Oscilloscope - Data Sheet

12 | Keysight | U2701A/U2702A USB Modular Oscilloscope - Data Sheet This information is subject to change without notice. © Keysight Technologies, 2012 - 2016 Published in USA, January 21, 2016 5990-9537EN www.keysight.com www.keysight.com/find/usbscope For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-01-01-16) www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with a three-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Infoline www.keysight.com/find/service Keysight’s insight to best in class information management. Free access to your Keysight equipment company reports and e-library. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. From Hewlett-Packard through Agilent to Keysight For more than 75 years, we‘ve been helping you unlock measurement insights. Our unique combination of hardware, software and people can help you reach your next breakthrough. Unlocking measurement insights since 1939.

1939 THE FUTURE