Digital Multimeters (DMMs) Data Sheet
Retool your expectations with the new Keysight Technologies, Inc. U1230 Series Handheld DMMs — the first to combine a built-in LED flashlight, both audible and visual alerts, and non-contact AC voltage detection in one handheld. Whether it is dark, noisy or even dangerous, the U1230 Series handheld digital multimeters keep you equipped with features that anticipate worst-case scenarios. The ergonomic shaped handheld allows you to single-handedly illuminate the test area with a built-in flashlight while selecting measurement functions using the rotary dial. Vsense performs non-contact voltage detection while continuity detection is made easy with the audible beeper alert and flashing backlight display. With the U1230 Series, you work better in the conditions you are in.
Features
– Built-in LED flashlight to illuminate test area – Flashing backlight as additional visual alert during continuity tests in noisy environments – Vsense to perform non-contact voltage detection – Data logging capability (stores up to 10 readings) – IR-to-USB connectivity to transfer data to PC for record Ergonomically shaped with a built-in flashlight Built for handheld users working in a poorly lit environment, the U1230 Series allows you to single-handedly illuminate your test area while making measurements with its easily activated built-in flashlight. Its ergonomic shape fits your hand, while the easily accessible rotary dial allows selection of measurement functions. Flashing backlight and beeping alert for continuity detection The U1230 Series is built for continuity detection in dark and noisy environments. Its audible beep and flashing backlight display provides increased visual and audio alert to indicate continuity. Non-contact voltage detection with Vsense The Vsense, a unique feature found in the U1233A model performs non-contact voltage detection. It delivers more safety while making measurements in dangerous working environments by avoiding any contact with hot or live wires. Upon detection of voltage, it produces a unique combination of beeping alert and blinking LED light to make measurements more efficiently – especially in a dark or noisy environment. 03 | Keysight | U1230 Series Handheld Digital Multimeters (DMMs) - Data Sheet
Overview of Keysight U1230 Series Handheld Digital Multimeters Key specifications U1231A U1232A U1233A Display Resolutions 6000 6000 6000 Basic DCV accuracy 0.5% + 2 counts 0.5% + 2 counts 0.5% + 2 counts Auto/manual ranging Yes Yes Yes Mesurement DCV 600 mV to 600 V 600 mV to 600 V 600 mV to 600 V ACV (RMS) 600 mV to 600 V 600 mV to 600 V 600 mV to 600 V DCI No 60 µA to 10 A 60 µA to 10 A ACI No 60 µA to 10 A 60 µA to 10 A Resistance 600 Ω to 60 MΩ 600 Ω to 60 MΩ 600 Ω to 60 MΩ Continuity, diode test Yes Yes Yes Capacitance 1000nF to 10mF 1000nF to 10mF 1000nF to 10mF Temperature No No 40 to 1372 0C Vsense for non-contact voltage detection No No Yes Zlow - low impedance mode Yes Yes Yes Connectivity IR-USB / Bluetooth IR-USB / Bluetooth IR-USB / Bluetooth Internal memory for data logging Yes (10 readings only) Yes (10 readings only) Yes (10 readings only) General Built-in flashlight Yes Yes Yes IP rating IP 42 IP 42 IP 42 Over-voltage safety protection CAT III 600V CAT III 600V CAT III 600V Battery life 500 hours 500 hours 500 hours Warranty 3 years 3 years 3 years 05 | Keysight | U1230 Series Handheld Digital Multimeters (DMMs) - Data Sheet
Accuracy ± (% of reading + counts of least significant digit) Test current Burden voltage/ shunt Input impedance U1231A/U1232A/ U1233A Where (applicable) Where (applicable) Where (applicable) Voltage 600 mV 1 0.1 mV 0.5% + 2 NA NA 11.18 MΩ 6 V 0.001 V 0.5% + 2 NA NA 11.18 MΩ 60 V 0.01 V 0.5% + 2 NA NA 10.1 MΩ 600 V 0.1 V 0.5% + 2 NA NA 10 MΩ 600 V (VZ LOW)2 0.1 V 2% + 3 NA NA 3 kΩ Resistance 600 Ω4 0.1 Ω 0.9% + 3 0.57 mA NA NA 6 kΩ4 0.001 k Ω 0.9% + 3 57 μA NA NA 60 kΩ 0.01 kΩ 0.9% + 3 5.7 μA NA NA 600 kΩ 0.1 kΩ 0.9% + 3 570 nA NA NA 6 MΩ5 0.001 MΩ 0.9% + 3 100 nA/10 MΩ NA NA 60 MΩ5 0.01 MΩ 1.5% + 3 100 nA/10 MΩ NA NA Diode 3 2 V 0.001 V 0.9% + 2 0.57 mA NA NA Current 4 60 μA1 0.01 μA 1.0% + 2 NA < 2.5 V/1 kΩ NA 600 μA1 0.1 μA 1.0% + 2 NA < 2.5 V/1 kΩ NA 6 A2,5 0.001 A 1.0% + 3 NA < 0.2 V/0.005 Ω NA 10 A2, 3 0.01 A 1.0% + 3 NA < 0.4 V/0.005 Ω NA Notes for DC voltage specifications: 1. The accuracy of the 600 mV range is specified after the Null function is used to subtract the thermal effect (by shorting the test leads). 2. For VZLOW (low input impedance) measurements, auto-ranging is disabled and the multimeter’s range is set to 600 V in the manual ranging mode. Notes for resistance specifications: 1. Overload protection: 600 Vrms for short circuits with < 0.3 A current. 2. Maximum open voltage is < +3 V. 3. Built-in buzzer beeps when the resistance measured is less than 23 Ω ± 10 Ω. The multimeter can capture intermittent measurements longer than 1 ms. 4. The accuracy of the 600 Ω to 6 kΩ range is specified after the Null function is used to subtract the test lead resistance and thermal effect (by shorting the test leads). 5. For the ranges of 6 MΩ and 60 MΩ, the RH is specified for < 60%. Notes for diode specifications: 1. Overload protection: 600 Vrms for short circuits with < 0.3 A current. 2. Built-in buzzer beeps continuously when the voltage measured is less than 50 mV and beeps once for forward-biased diode or semiconductor 3. Open voltage for diode: < +3 V DC. 4. The maximum display for diode measurements is 2100 counts. Notes for DC current specifications: 1. Overload protection for 60 μA to 600 μA range: 600 Vrms for short circuits with < 0.3 A current. 2. Overload protection for 6 A to 10 A range: 11 A/1000 V; 10 × 38 mm fast-acting fuse. 3. Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals > 10 A to 20 A for 30 seconds maximum. After measuring currents > 10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low current measurements. 4. Only applicable for the U1232A/U1233A model 5. DC current between ± (0.6 mA and 1 mA) is not measureable on the U1232A and U1233A models. 06 | Keysight | U1230 Series Handheld Digital Multimeters (DMMs) - Data Sheet
Electrical Specifications (continued) AC specifications True rms AC voltage and AC current specifications Function Range Resolution Accuracy ± (% of reading + counts of least significant digit) Burden voltage/shunt
45 Hz to 500 Hz 500 Hz to 1 kHz Where (applicable)
Voltage 600 mV 0.1 mV 1.0% + 3 2.0% + 3 NA 6 V 0.001 V 1.0% + 3 2.0% + 3 NA 60 V 0.01 V 1.0% + 3 2.0% + 3 NA 600 V 0.1 V 1.0% + 3 2.0% + 3 NA 600 (VZ LOW)3 0.1 V 2.0% + 3 4.0% + 3 NA Current 1 60 μA 2 0.01 μA 1.5% + 3 NA < 2.5 V/1 kΩ 600 μA 2 0.1 μA 1.5% + 3 NA < 2.5 V/1 kΩ 6 A3,5 0.001 A 1.5% + 3 NA < 0.2 V/0.005 Ω 10 A3, 4 0.01 A 1.5% + 3 NA < 0.4 V/0.005 Ω Notes for true rms ac voltage specifications: 1. Overload protection: 600 Vrms. For millivolt measurements, 600 Vrms for short circuits with < 0.3 A current. 2. Input impedance: 10 MΩ (nominal) in parallel with < 100 pF. 3. VZLOW input impedance: 3 kΩ (nominal). Notes for ac current specifications: 1. AC current measurement not available for U1231A model. 2. Overload protection for 60 μA to 600 μA range: 600 Vrms for short circuits with < 0.3 A current. 3. Overload protection for 6 A to 10 A range: 11 A/1000 V; 10 × 38 mm fast-acting fuse. 4. Specification for 10 A range: 10 A continuous. Add 0.3% to the specified accuracy when measuring signals > 10 A to 20 A for 30 seconds maximum. After measuring currents > 10 A, cool down the multimeter for twice the duration of the measured time before proceeding with low current measurements. 5. AC current between 0.6 mA and 300 mA is not measureable on the U1232A and U1233A models. Capacitance specifications Range Resolution Accuracy± (% of reading + counts of least significant digit) Measuring rate (at full scale)U1231A/U1232A/U1233A 1000 nF 1 nF 1.9% + 2 4 times/second 10 μF 0.01 μF 1.9% + 2 4 times/second 100 μF 0.1 μF 1.9% + 2 4 times/second 1000 μF 1 μF 1.9% + 2 1 time/second 10 mF 0.01 mF 1.9% + 2 0.1 time/second 1. Overload protection: 600 Vrms for short circuits with < 0.3 A current. 2. The accuracy of for all ranges is specified based on a film capacitor or better, and after the Null function is used to subtract the test lead resistance and thermal effect (by opening the test leads). 3. The maximum display is 1200 counts. 07 | Keysight | U1230 Series Handheld Digital Multimeters (DMMs) - Data Sheet
Electrical Specifications (continued) Temperature specifications Thermal type Range Resolution Accuracy± (% of reading + counts of least significant digit) U1233A K –40 °C to 1372 °C 0.1 °C 1% + 1 °C –40 °F to 2502 °F 0.1 °F 1% + 1.8 °F 1. The specification above is specified after 60 minutes of warm up time. If the unit is exposed during storage in high humidity (condensing) environment, 120 minutes of operating time is required instead. 2. The accuracy does not include the tolerance of the thermocouple probe. 3. Do not allow the temperature sensor to contact a surface that is energized above 30 Vrms or 60 V DC. Such voltages poses a shock hazard. 4. The temperature calculation is specified according to the safety standards of EN/IEC-60548-1and NIST175. 5. The approximate ambient temperature (cold-junction compensation) is shown on the display when you have an open thermocouple.The open thermocouple message may be due to broken (open) probe or because no probe is installed into the input jacks of the multimeter. 6. For temperature measurement on U1233A, the type-K thermocouple probe and adapter such as the U1186A (purchase separately) is required. 7. For auxillary temperature measurement on U1231A & U1232A, a temperature module such as the U1586B (purchase separately) is required. Frequency specifications Range Resolution Accuracy± (% of reading + counts of least significant digit) Minimum input frequencyU1231A/U1232A/U1233A 99.99 Hz 0.01 Hz 0.1% + 2 5 Hz 999.9 Hz 0.1 Hz 0.1% + 2 9.999 kHz 1 Hz 0.1% + 2 99.99 kHz 10 Hz 0.1% + 2 1. Overload protection: 600 V; input signal is < 20,000,000 V × Hz (product of voltage and frequency). 08 | Keysight | U1230 Series Handheld Digital Multimeters (DMMs) - Data Sheet
Electrical Specifications (continued) Frequency sensitivity specifications For voltage measurements Input range Minimum sensitivity (rms sine wave) Maximum input for specified accuracy 1
5 Hz to 50 kHz
600 mV in Scale mode 50 mV 50 mV 50 mV 600 mV 120 mV 120 mV 120 mV 6 V 0.6 V 0.6 V 0.6 V 60 V 5.0 V 5.0 V 5.0 V
600 V 50 V 50 V 50 V
- Maximum input for specified accuracy, refer to “AC specifications” on page 106 of the User Guide. For current measurements Input range Minimum sensitivity (rms sine wave) Maximum input for specified accuracy 1
45 Hz to 5 kHz
60 μA 30 μA 30 μA 600 μA 30 μA 30 μA 6 A 0.5 A 0.5 A 10 A 0.5 A 0.5 A 1. Maximum input for specified accuracy, refer to “AC specifications” on page 106 of the User Guide. Scale transfer (mV) Range Resolution Accuracy ± (% of reading + counts of least significant digit) U1231A/U1232A/U1233A DC 600 mV 0.1 mV 0.5% + 22 AC 600 mV 0.1 mV 1.0 % + 3 @ 45 Hz to 500 Hz 2.0 % + 3 @ 500 Hz to 1 kHz 1. Overload protection: 600 Vrms for short circuits with < 0.3 A current. 2. The accuracy of the DC 600 mV range is specified after the Null function is used to subtract the thermal effect (by shorting the test leads). 3. Input impedance: 10 MΩ (typical). 09 | Keysight | U1230 Series Handheld Digital Multimeters (DMMs) - Data Sheet
Electrical Specifications (continued) Display update rate (approximate) Function Times/second U1231A U1232A/U1233A AC V (V or mV) 5 5 DC V (V or mV) 5 5 AC V/DC V (VZ LOW) 1 1 Scale transfer (mV) 5 5 Ω 5 5 Diode 5 5 Capacitance 4 (< 100 μF) 4 (< 100 μF) DC A (μA, mA, or A) NA 5 AC A (μA, mA, or A) NA 5 Frequency 1 (> 10 Hz) 1 (> 10 Hz) 10 | Keysight | U1230 Series Handheld Digital Multimeters (DMMs) - Data Sheet
Parameter U1231A/U1232A/U1233A Power supply Battery type – 4 × 1.5 V AAA Alkaline battery (ANSI/NEDA 24A or IEC LR03), or – 4 × 1.5 V AAA Zinc Chloride battery (ANSI/NEDA 24D or IEC R03) Battery life – 500 hours typical (based on new Alkaline batteries) with backlight and flashlight disabled Low battery indication – Low battery indicator will flash when the battery voltage drops below approximately 4.4 V Power consumption 450 mVA maximum (with backlight and flashlight enabled) Fuse 10 × 38 mm 11 A/1000 V fast-acting fuse Display Liquid crystal display (LCD) (with maximum reading of 6600 counts) Flashlight Cool white LED (5500 K typical); luminous intensity from 2240 mcd to 5600 mcd Operating environment – Operating temperature from –10 °C to 55 °C, 0% to 80% RH – Full accuracy up to 80% RH for temperatures up to 30 °C, decreasing linearly to 50% RH at 55 °C – Altitude up to 2000 meters – Pollution degree II Storage compliance –40 °C to 60 °C, 0% to 80% RH without batteries Safety compliance EN/IEC 61010-1:2001, ANSI/UL 61010-1:2004, and CAN/CSA-C22.2 No. 61010-1-04 Measurement category CAT III 600 V Electromagnetic compatibility (EMC) Commercial limits compliance with EN61326-1 Temperature coefficient 0.1 × (specified accuracy) / °C (from –10 °C to 18 °C, or 28 °C to 55 °C) Common Mode Rejection Ratio (CMRR) > 100 dB at DC, 50/60 Hz (1 k Ω unbalanced) Normal Model Rejection Ration (NMRR) > 60 dB at 50/60 Hz Dimensions (H x W x D) 169 mm × 86 mm × 52 mm Weight U1232A and U1233A: 371 grams (with batteries and holster) U1231A: 365 grams (with batteries and holster) Warranty – Three years for product 1 – Three months for product’s accessories Calibration cycle One year Please take note that for the product, the warranty does not cover: – Damage from contamination – Normal wear and tear of mechanical components – Manuals, fuses, and batteries Specification assumptions – Accuracy is given as ±(% of reading + counts of least significant digit) at 23 °C ± 5 °C, with relative humidity less than 80% RH. – AC V and AC A specifications are AC coupled, true RMS and are valid from 5% of range to 100% of range. – The crest factor may be up to 3.0 at full-scale (4000 counts) – For non-sinusoidal waveforms, add (2% reading + 2% full scale) typical. – After VZ LOW (low input impedance) voltage measurements, wait at least 20 minutes for thermal impact to cool before proceeding with any other measurement. 11 | Keysight | U1230 Series Handheld Digital Multimeters (DMMs) - Data Sheet
Ordering Information
Standard U1231A, U1232A and U1233A include: – Quick Start Guide – Certificate of Calibration (CoC) – U1167A 4 mm Tips probes test leads – 4 x 1.5 V batteries Recommended accessories U1174A Soft carrying case U1168A Standard test lead kit U1173A IR-to-USB cable U1171A Magnetic hanging kit U1186A Thermocouple (K-Type) and Temperature Probe Adapter Note: For temperature measurement on the U1233A, a type-K thermocouple probe and adapter such as the U1186A (purchased separately) is recommended. It is only compatible with the U1233A. U1586B Temperature Module Note: For auxillary temperature measurement on the U1231A and U1232A, a temperature module such as the U1586B (purchased separately) is recommended. 12 | Keysight | U1230 Series Handheld Digital Multimeters (DMMs) - Data Sheet
www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with three-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Infoline www.keysight.com/find/service Keysight’s insight to best in class information management. Free access to your Keysight equipment company reports and e-library. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. From Hewlett-Packard through Agilent to Keysight For more than 75 years, we‘ve been helping you unlock measurement insights. Our unique combination of hardware, software and people can help you reach your next breakthrough. Unlocking measurement insights since 1939.
1939 THE FUTURE
For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 11 2626 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-02-10-16) www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2015 Quality Management System 13 | Keysight | U1230 Series Handheld Digital Multimeters (DMMs) - Data Sheet This information is subject to change without notice. © Keysight Technologies, 2013 -2016 Published in USA, April 29, 2016 5990-7550EN www.keysight.com www.keysight.com/find/u1230dmm