GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM FLYING LEAD TEMPERATURE TRANSMITTER TXFL SERIES PRODUCT DESCRIPTION The single point flying lead temperature transmitter utilizes a precision sensor encapsulated in 6mm (0.236”) OD x 50mm (2”), 304 series stainless steel probe. Standard wire length is 3.05m (10’). All probes are constructed to provide excellent heat transfer, fast response and are potted to resist moisture penetration. A transmitter that provides a high precision signal with excellent long term stability, low hysteresis and fast response is provided. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. A typical application for the flying lead type probes is to monitor a single point temperature within the duct. Install the probe in a straight section of duct at a suitable distance downstream from any heating, cooling, or humidification devices. Drill a 3/8” hole in the top of the duct and hang the sensor in the air-stream. The enclosure provides mounting holes for ease of installation NOTE: This product is factory calibrated and any field adjustment will void the warranty. CABLE GLAND FITTING THREAD ADAPTER 1/2” NPT TO M16 ACCESSORIES - INCLUDED WITH E ENCLOSURE OPTION SENSOR TYPE 1000 Ω platinum RTD SENSOR ACCURACY ±0.3°C (±0.54°F) @ 0°C (32°F) PROBE SENSING RANGE -40 to 60°C (-40 to 140°F) WIRE MATERIAL FT-6 rated plenum cable, 22 AWG WIRE LENGTH 3.05m (10’) PROBE MATERIAL 304 series stainless steel PROBE DIAMETER 6 mm (0.236”) PROBE LENGTH 50 mm (2”) OUTPUT SIGNAL 4-20 mA current loop, 0-5 Vdc, or 0-10 Vdc (factory configured) TRANSMITTER ACCURACY ±0.1% of span, including linearity OUTPUT DRIVE @ 24 VDC Current: 600 mA maximum Voltage: 10 KΩ minimum POWER SUPPLY 0-5 Vdc: 10-35 Vdc or 10-28 Vac 0-10 Vdc: 15-35 Vdc or 15-28 Vac 4-20 mA: 15-35 Vdc (loop-powered) or 22-28 Vac CURRENT CONSUMPTION Current: 20 mA Voltage: 5 mA MAXIMUM CURRENT (VOLTAGE) 5 mA nominal MAXIMUM OUTPUT (VOLTAGE) Limited to <5.5 Vdc or 0-5 Vdc, <10.5 for 0-10 Vdc INPUT VOLTAGE EFFECT Negligible over specified operating range PROTECTION CIRCUITRY Reverse voltage protected and output limited AMBIENT OPERATING RANGE -40 to 50°C (-40 to 122°F), 5 to 95 %RH non-condensing ENCLOSURE A: ABS, UL94-V0, IP65 (NEMA 4X) E: Same as A, with thread adapter (1/2” NPT to M16), and cable gland fitting TERMINATION Screw terminal block (14 to 22 AWG) APPROVALS CE COUNTRY OF ORIGIN Canada SPECIFICATIONS 82.5 mm 3.25" 69.8 mm 2.75" 1/2” NPT 76.2 mm 3.00" 52.0 mm 2.05" 3.05 m 10.00’ 6.0 mm 0.236" 50 mm FT-6 Rated Plenum Cable, 22 AWG 304 Series S/S Probe

PRINTED IN CANADA Copyright © Greystone Energy Systems Inc. All Rights Reserved www.greystoneenergy.com PS-TXFLXXX-03 Greystone Energy Systems, Inc.

150 English Drive, Moncton,

New Brunswick, Canada E1E 4G7 Ph: +1 (506) 853-3057 Fax: +1 (506) 853-6014 North America: 1-800-561-5611 E-mail: mail@greystoneenergy.com PRODUCT TXFL Flying Lead Temperature Transmitter ENCLOSURE A E ABS, with hinged and gasketed cover Same as A, with thread adapter (1/2” NPT to M16) and cable gland fitting SENSOR 12X 1000 Ω Platinum, IEC 751, 385 Alpha, thin film OUTPUT A D E 4-20mA 0-5 Vdc 0-10 Vdc SCALED RANGE 001 002 0 to 35°C (32 to 95°F) 0 to 50°C (32 to 122°F) Custom ranges available ORDERING TXFL PART NUMBER NOTE: Greystone Energy Systems, Inc. reserves the right to make design modifications without prior notice. WIRING INFORMATION TERMINAL FUNCTION PWR Power Supply OUT Analog Output COM Common NEG SEN Temperature Sensor Input EXC