GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM ROOM CARBON DIOXIDE DETECTOR CD2RMC SERIES PRODUCT DESCRIPTION The room CO2 transmitter device uses a highly accurate and reliable nondispersive infrared (NDIR) sensor in an attractive, low profile enclosure for room applications to monitor CO2 levels. The sensor uses dual wavelength optics and LTA (long term adjustment) signal processing technology to deliver industry leading long-term accuracy and reliability. These technology features ensure optimum measurement stability for both periodic and constant occupancy applications, so the device is equally suitable for a classroom or a hospital room. Standard features include a field selectable output signal of either 4-20 mA, 0-5 Vdc or 0-10 Vdc for the highest versatility, programmable CO2 measurement span, a backlit alpha-numeric LCD and easy menu operation for configuration. Optional features include a resistive temperature sensor output (with LCD display of temperature in either °C or °F), 2 button setpoint adjustment, a control relay with programmable setpoint, hysteresis and time delay, and a dry-contact override switch. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. The CD2RMC series can be mounted directly to a single gang electrical box or directly to a wall. The backplate includes many mounting hole configurations to allow for mounting on a variety of electrical boxes. The basic CD2RMC has a 3 wire configuration with a screw block terminal provided for connection to the Building Automation System. GAS TYPE DETECTED Carbon Dioxide (CO2) SENSOR TYPE Dual channel non-dispersive infrared (NDIR) SENSOR ACCURACY ± (30ppm + 3% of measured value) MEASUREMENT RANGE 0-2000ppm, adjustable 1000 - 10000ppm TEMPERATURE DEPENDENCY ±2.5ppm/°C RESPONSE TIME 20 seconds (T63) WARM-UP TIME 1 minute SENSOR COVERAGE AREA 100 m2 (1000ft2) typical SENSOR LIFE SPAN >15 years TRANMSITTER ACCURACY ±0.25% of span (including linearity, hysteresis and repeatability) POWER SUPPLY 24 Vdc ±20% or 24 Vac ±10% (non-isolated half-wave rectified) PROTECTION CIRCUITRY Reverse voltage protected and transient protected INPUT VOLTAGE EFFECT Negligible over specified operating range OUTPUT SIGNAL TYPE 4-20 mA (3-wire), 0-5 or 0-10 Vdc (field selectable) CURRENT CONSUMPTION Current: 75 mA @ 24 Vdc max, 150 mA @ 24 Vac max Voltage: 50 mA @ 24 Vdc max, 100 mA @ 24 Vac max OUTPUT DRIVE @ 24 VDC Current: 550Ω max Voltage: 10,000Ω min AMBIENT OPERATING RANGE 0 to 50°C (32 to 122°F), 0 to 95 %RH non-condensing STORAGE TEMPERATURE -40 to 70°C (-40 to 158°F) LCD DISPLAY Units: ppm (CO2), °C/°F (optional temperature/setpoint) Range: 0 to 10000ppm, 0 to 50°C (32 to 122°F) Size: 35mm W x 15mm H (1.4” x 0.6”), 2 lin x 8 character, alpha-numeric Digit Height: 2-line x 8 character OPTIONAL TEMPERATURE SENSOR Type: Thermistor and RTD (see ordering chart) Accuracy: See ordering chart Output: 2-wire resistive OPTIONAL RELAY (2-WIRE OUTPUT) Rating: Form A (N.O.), 2 Amps @ 140 Vac / 30 Vdc OPTIONAL OVERRIDE SWITCH (2-WIRE OUTPUT) Rating: 50 mA @ 12 Vdc max OPTIONAL SETPOINT CONTROL Type: Front panel up/down pushbuttons Range: ±10 resistive steps, range 16 to 26°C in 0.5°C increments or 60 to 80°F in 1°F increments Midpoint: Default 21°C/70°F, programmable 18 to 25°C (64 to 77°F) Resolution: Programmable 0.5 / 1°C/°F Action: Programmable direct or reverse acting ENCLOSURE Material: ABS, White Dimensions: 84mm W x 119mm H x 29mm D (3.3” x 4.7” x 1.15”) Protection: IP30 (NEMA 1) WIRING Screw terminal block (14 to 22 AWG) APPROVALS CE COUNTRY OF ORIGIN Canada SPECIFICATIONS NOTE: This CO2 sensor incorporates a Self Calibration feature to correct CO2 sensor drift. This feature is recommended for applications where the CO2 level will be close to normal (400 ppm) at least one hour per day. If the monitored space is occupied 24 hours or consistently maintains higher or lower levels of CO2, it is recommended that this feature be turned off, but yearly calibration will be required. 58 mm 2.3" 82.6 mm 3.25" 29 mm 1.15" 119 mm 4.7" 84 mm 3.3"

PRINTED IN CANADA Copyright © Greystone Energy Systems Inc. All Rights Reserved www.greystoneenergy.com PS-CD2RMCXXX-02 Greystone Energy Systems, Inc.

150 English Drive, Moncton,

New Brunswick, Canada E1E 4G7 Ph: +1 (506) 853-3057 Fax: +1 (506) 853-6014 North America: 1-800-561-5611 E-mail: mail@greystoneenergy.com WIRING INFORMATION TERMINAL FUNCTION SETPNT Resistance Output CO2 Analog Output COM COMMON PWR Supply Voltage TEMP Resistance Output SWITCH Digital Output RELAY Digital Output PRODUCT CD2RMC Room Carbon Dioxide Sensor DISPLAY C V Concealed LCD (Not available if setpoint selected) Viewable LCD OPTIONAL TEMPERATURE SENSOR XX None 100 Ω Platinum, IEC 751, 385 Alpha, thin film, 3-wire 1801 Ω NTC Thermistor, ±0.2°C 3000 Ω NTC Thermistor, ±0.2°C 10,000 Ω Type 3, NTC Thermistor, ±0.2°C 2.252K Ω NTC Thermistor, ±0.2°C 1000 Ω Platinum, IEC 751, 385 Alpha, thin film 1000 Ω Nickel, Class B, DIN 43760 10,000 Ω Type 3, NTC Thermistor, ±0.2°C c/w 11,000 shunt resistor 20,000 Ω NTC Thermistor, ±0.2°C 10,000 Ω Type 2, NTC Thermistor, ±0.2°C OPTIONAL RELAY X R None Adjustable Relay OPTIONAL OVERRIDE X S None Override OPTIONAL SETPOINT ADJUSTMENT XXX P00 P01 P02 None 0 to 10,000Ω 20,000 to 30,000Ω 2,000 to 3,000Ω ORDERING PART NUMBER NOTE: Greystone Energy Systems, Inc. reserves the right to make design modifications without prior notice. NOTE: Additional setpoint values are available. Please contact Greystone. 5-YEAR CALIBRATION GUARANTEE Greystone offers a 5-year calibration guarantee on all its CD series wall and duct mount sensors used for CO2 based ventilation control when operated in an environment that can utilize ASC software. If the sensor is found to be out of calibration more than 150 PPM as compared to a calibration gas or recently calibrated reference, Greystone will provide a free factory calibration of the sensor if returned to Greystone. This guarantee only applies if the sensor is operated in an environment where inside levels periodically drop to outside concentrations (i.e. during evenings or weekends when there is no occupancy) as is required by ASC software. ACCESSORIES CDD1-CALKIT-GS Calibration kit (Gas not included) for calibrating CD & CDD series CO2 Transmitters. SETPNT CO2 COM PWR TEMP SWITCH RELAY MENUUPDOWN OVERRIDE CO2 SENSOR