TXDR GREYSTONE | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 2
Technical content
GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM RIGID DUCT AVERAGE TEMPERATURE TRANSMITTER TXDR SERIES CABLE GLAND FITTING THREAD ADAPTER 1/2” NPT TO M16 ACCESSORIES - INCLUDED WITH E ENCLOSURE OPTION PRODUCT DESCRIPTION The multi-point rigid duct average temperature transmitter incorporates numerous precision platinum RTD’s at equal distances, encapsulated in a 6.00mm (0.236”) OD, 304 series stainless steel probe and is available in various lengths. All probes provide excellent heat transfer, fast response, and resist moisture penetration. A transmitter that provides a high accuracy signal with excellent long term stability, low hysteresis and fast response is available with various ranges. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. The rigid duct average type probes are installed in the side of the duct to monitor the average temperature within the duct. Select a probe length that allows the probe to span the duct width. Install the probe in a straight section of duct at a suitable distance downstream from any heating, cooling, or humidification devices. The enclosure provides mounting tabs for ease of installation. NOTE: This product is factory calibrated and any field adjustment will void the warranty. SENSOR TYPE 1000 Ω platinum RTD SENSOR ACCURACY ±0.3°C (±0.54°F) @ 0°C (32°F) PROBE SENSING RANGE -40 to 60°C (-40 to 140°F) WIRE MATERIAL PVC/Kynar, 28 AWG PROBE MATERIAL 304 series stainless steel PROBE DIAMETER 6 mm (0.236”) STANDARD LENGTHS 450, 600, 900 mm (18” , 24” , 36”) OUTPUT SIGNAL 4-20 mA current loop, 0-5 Vdc, or 0-10 Vdc (factory configured) TRANSMITTER ACCURACY ±0.1% of span, including linearity OUTPUT DRIVE @ 24 VDC Current: 600 mA maximum Voltage: 10 KΩ minimum POWER SUPPLY 0-5 Vdc: 10-35 Vdc or 10-28 Vac 0-10 Vdc: 15-35 Vdc or 15-28 Vac 4-20 mA: 15-35 Vdc (loop-powered) or 22-28 Vac CURRENT CONSUMPTION Current: 20 mA Voltage: 5 mA MAXIMUM CURRENT (VOLTAGE) 5 mA nominal MAXIMUM OUTPUT (VOLTAGE) Limited to <5.5 Vdc or 0-5 Vdc, <10.5 for 0-10 Vdc INPUT VOLTAGE EFFECT Negligible over specified operating range PROTECTION CIRCUITRY Reverse voltage protected and output limited AMBIENT OPERATING RANGE -40 to 50°C (-40 to 122°F), 5 to 95 %RH non-condensing ENCLOSURE A: ABS, UL94-V0, IP65 (NEMA 4X) E: Same as A, with thread adapter (1/2” NPT to M16), and cable gland fitting TERMINATION Screw terminal block (14 to 22 AWG) APPROVALS CE COUNTRY OF ORIGIN Canada SPECIFICATIONS 82.5 mm 3.25" 69.8 mm 2.75" Various Probe Lengths See Specifications 6 mm (0.236") 76.2 mm 3.00" 0.5" NPT Foam Gasket
304 Series S/S Probe
52.0 mm 2.05"
PRINTED IN CANADA Copyright © Greystone Energy Systems Inc. All Rights Reserved www.greystoneenergy.com PS-TXDRXXX-02 06/20 Greystone Energy Systems, Inc.
150 English Drive, Moncton,
New Brunswick, Canada E1E 4G7 Ph: +1 (506) 853-3057 Fax: +1 (506) 853-6014 North America: 1-800-561-5611 E-mail: mail@greystoneenergy.com PRODUCT TXDR Rigid Duct Average Temperature Transmitter ENCLOSURE A E ABS, with hinged and gasketed cover Same as C, with thread adapter and cable gland fitting SENSOR 12 1000 Ω Platinum, IEC 751, 385 Alpha, thin film PROBE LENGTH F G H 450mm (18”) 600mm (24”) 900mm (36”) OUTPUT A D E 4-20 mA 0-5 Vdc 0-10 Vdc SCALED RANGE 001 002 006 0 to 35°C (32 to 95°F) 0 to 50°C (32 to 122°F) -50 to 50°C (-58 to 122°F) Custom ranges available ORDERING TXDR PART NUMBER NOTE: Greystone Energy Systems, Inc. reserves the right to make design modifications without prior notice. WIRING INFORMATION TERMINAL FUNCTION PWR Power Supply OUT Analog Output COM Common NEG SEN Temperature Sensor Input EXC