TXDF GREYSTONE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM FLEX-DUCT AVERAGE TEMPERATURE TRANSMITTER TXDF SERIES PRODUCT DESCRIPTION The flexible, multi-point duct averaging mounted temperature transmitter is available with a selection of platinum RTD sensors and a transmitter that provides a high accuracy signal with excellent long term stability, low hysteresis and fast response. They are available with various scaled ranges. The sensing cable is constructed to provide excellent heat transfer, fast response time, and is available in several lengths and quantity of sensing elements. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. The flex-duct average probes are installed through a hole in the side of the duct to monitor an average temperature within the duct. Select a probe length that allows for criss-crossing the duct multiple times. Install the probes in a straight section of duct at a suitable distance downstream from any heating, cooling, or humidification devices. The cable probe needs to be fastened onto hangers using tube clamps or wire ties and should be secured every 100 cm or 3’ maximum to prevent movement of the wire and prevent wear. If sensor is to be used in high velocity or vibration environment use of rigid style duct probe is recommended. The enclosure provides mounting tabs for ease of installation. NOTE: This product is factory calibrated and any field adjustment will void the warranty. SENSOR TYPE 1000 Ω platinum RTD SENSOR ACCURACY ±0.3°C (±0.54°F) @ 0°C (32°F) PROBE SENSING RANGE -20 to 60°C (-4 to 140°F) WIRE MATERIAL FT-6 rated plenum cable, 22 AWG STANDARD LENGTHS 1800, 3600, 6100, 7300 mm OUTPUT SIGNAL 4-20 mA current loop, 0-5 Vdc, or 0-10 Vdc (factory configured) TRANSMITTER ACCURACY ±0.1% of span, including linearity OUTPUT DRIVE @ 24 VDC Current: 600 mA maximum Voltage: 10 KΩ minimum POWER SUPPLY 0-5 Vdc: 10-35 Vdc or 10-28 Vac 0-10 Vdc: 15-35 Vdc or 15-28 Vac 4-20 mA: 15-35 Vdc (loop-powered) or 22-28 Vac CURRENT CONSUMPTION Current: 20 mA Voltage: 5 mA MAXIMUM CURRENT (VOLTAGE) 5 mA nominal MAXIMUM OUTPUT (VOLTAGE) Limited to <5.5 Vdc or 0-5 Vdc, <10.5 for 0-10 Vdc INPUT VOLTAGE EFFECT Negligible over specified operating range PROTECTION CIRCUITRY Reverse voltage protected and output limited AMBIENT OPERATING RANGE -40 to 50°C (-40 to 122°F), 5 to 95 %RH non-condensing ENCLOSURE A: ABS, UL94-V0, IP65 (NEMA 4X) E: Same as A, with thread adapter (1/2” NPT to M16), and cable gland fitting TERMINATION Screw terminal block (14 to 22 AWG) APPROVALS CE COUNTRY OF ORIGIN Canada SPECIFICATIONS 82.5 mm 3.25" 69.8 mm 2.75" 52.0 mm 2.05" 76.2 mm 3.00" 0.5” NPT Foam Gasket

304 Series S/S Probe

CABLE GLAND FITTING THREAD ADAPTER 1/2” NPT TO M16 ACCESSORIES - INCLUDED WITH E ENCLOSURE OPTION

PRINTED IN CANADA Copyright © Greystone Energy Systems Inc. All Rights Reserved www.greystoneenergy.com PS-TXDFXXX-03 Greystone Energy Systems, Inc.

150 English Drive, Moncton,

New Brunswick, Canada E1E 4G7 Ph: +1 (506) 853-3057 Fax: +1 (506) 853-6014 North America: 1-800-561-5611 E-mail: mail@greystoneenergy.com PRODUCT TXDF Flexible Cable Duct Average Temperature Transmitter ENCLOSURE A E ABS, with hinged and gasketed cover Same as A, with thread adapter and cable gland fitting SENSOR 12 1000 Ω Platinum, IEC 751, 385 Alpha, thin film PROBE LENGTH I J K L 1800mm (6’) (4 sensors) 3600mm (12’) (4 sensors) 6100mm (20’) (4 sensors) 7300mm (24’) (9 sensors) OUTPUT A D E 4-20 mA 0-5 Vdc 0-10 Vdc SCALED RANGE 001 002 0 to 35°C (32 to 95°F) 0 to 50°C (32 to 122°F) Additional ranges available ORDERING TXDF PART NUMBER NOTE: Greystone Energy Systems, Inc. reserves the right to make design modifications without prior notice. WIRING INFORMATION TERMINAL FUNCTION PWR Power Supply OUT Analog Output COM Common NEG SEN Temperature Sensor Input EXC