PS-TSDF GREYSTONE | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 2
Technical content
GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM FLEXIBLE CABLE DUCT AVERAGE TEMPERATURE SENSOR TSDF SERIES CABLE GLAND FITTING THREAD ADAPTER 1/2” NPT TO M16 ACCESSORIES - INCLUDED WITH E ENCLOSURE OPTION PRODUCT DESCRIPTION The flexible multi-point duct average temperature sensor utilizes several precision sensors spaced at equal distances. The probe is FT-6 rated plenum cable and is available in various lengths. All probes are constructed to provide excellent heat transfer and a fast response. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. The flex-duct average probes are installed through a hole in the side of the duct to monitor an average temperature within the duct. Select a probe length that allows for criss-crossing the duct multiple times. Install the probes in a straight section of duct at a suitable distance downstream from any heating, cooling, or humidification devices. The cable probe needs to be fastened onto hangers using tube clamps or wire ties and should be secured every 100 cm or 3’ maximum to prevent movement of the wire and prevent wear. If sensor is to be used in high velocity or vibration environment use of rigid style duct probe is recommended. The enclosure provides mounting tabs for ease of installation. SENSOR TYPE Thermistor or RTD (see ordering chart) SENSOR ACCURACY Thermistors: ±0.2°C (±0.36°F) @ 25°C (77°F) Platinum RTD’s: ±0.3°C (±0.54°F) @ 0°C (32°F) Nickel RTD’s: ±0.4°C (±0.72°F) @ 0°C (32°F) PROBE SENSING RANGE -20 to 60°C (-4 to 140°F) AMBIENT OPERATING RANGE -40 to 50°C (-40 to 122°F), 5 to 95 %RH non-condensing WIRE MATERIAL FT-6 rated plenum cable, 22 AWG STANDARD LENGTHS 1800, 3600, 6100, 7300mm ENCLOSURE ABS, UL94-V0, IP65 (NEMA 4X) C: includes terminal block E: same as C, with thread adapter (1/2” NPT to M16), and cable gland fitting TERMINATION A: pigtail, 2 or 3 wire C & E: terminal block, 2 or 3 wire COUNTRY OF ORIGIN Canada SPECIFICATIONS 82.5 mm 3.25" 69.8 mm 2.75" 52.0 mm 2.05" 76.2 mm 3.00" 0.5” NPT Foam Gasket
304 Series S/S Probe
PRINTED IN CANADA Copyright © Greystone Energy Systems Inc. All Rights Reserved www.greystoneenergy.com PS-TSDFXXX-04 Greystone Energy Systems, Inc.
150 English Drive, Moncton,
New Brunswick, Canada E1E 4G7 Ph: +1 (506) 853-3057 Fax: +1 (506) 853-6014 North America: 1-800-561-5611 E-mail: mail@greystoneenergy.com PRODUCT TSDF Flexible Cable Duct Average Temperature Sensor ENCLOSURE A C E ABS, with hinged and gasketed cover Same as A, with terminal block Same as C, with thread adapter and cable gland fitting SENSOR 02 100 Ω Platinum, IEC 751, 385 Alpha, thin film 1801 Ω NTC Thermistor, ±0.2°C 3000 Ω NTC Thermistor, ±0.2°C 10,000 Ω Type 3, NTC Thermistor, ±0.2°C 2.252K Ω NTC Thermistor, ±0.2°C 1000 Ω Platinum, IEC 751, 385 Alpha, thin film 1000 Ω Nickel, Class B, DIN 43760 10,000 Ω Type 3, NTC Thermistor, ±0.2°C c/w 11K shunt resistor 20,000 Ω NTC Thermistor, ±0.2°C 10,000 Ω Type 2, NTC Thermistor, ±0.2°C PROBE LENGTH I J K L 1800mm (6’) 4 sensors 3600mm (12’) 4 sensors 6100mm (20’) 4 sensors 7300mm (24’) 9 sensors ORDERING TSDF PART NUMBER NOTE: Greystone Energy Systems, Inc. reserves the right to make design modifications without prior notice.