Tektronix DMM4050 and DMM4040 Datasheet DMM4050 Features & Benefits Key Performance Specifications

6.5 Digit Resolution

Basic VDC Accuracy of up to 0.0024% (1 yr.) 100 mV to 1000 V Voltage Range, with up to 100 nV Resolution 100 μA to 10 A Current Range, with up to 100 pA Resolution 10 Ωt o1GΩRange, with up to 10μΩResolution CAT I 1000 V, CAT II 600 V Available Functions and Features Volts, Ohms, and Amps Measurements True RMS (AC, AC + DC) Measurements Diode and Continuity Testing Frequency and Period Measurements Temperature and Capacitance Measurements (DMM4050) 2×4 Ohms 4-wire Measurement Technique TrendPlot™ Paperless Data Recorder Mode Measurement Statistics Histogram Mode Connectivity Front and Rear 2×4 Measurement Inputs USB Host Port on Front Panel for Easy Storage of Measurement Data and Instrument Settings RS-232, LAN, and GPIB Ports on RearPanel for Quick PC Connectivity Includes USB to RS-232 Interface Adapter Cable Includes National Instrument’s LabVIEW SignalExpress™ TE Limited Edition for Connecting Your Bench 3-year Warranty

TrendPlot display. Feature-Rich Tools for Precision Measurements As the circuits in embedded system designs become more sophisticated with tighter tolerances, you must measure a multitude of different parameters with a high degree of accuracy to validate your design. The Tektronix DMM4050 and DMM4040 6.5 digit bench multimeters pack many different functions and analysis into one instrument, all with exceptional precision and performance. Typical multimeter measurements – volts, ohms, and amps – are made with a basic VDC accuracy of up to 0.0024%, and resolution of 100 pA and 10 μΩ,e n s u r ing you have the performance you need for today’s demanding designs. You can also use the DMM4050/4040 to measure frequency and period, and to perform continuity and diode tests. For additionalflexibility, the DMM4050 offers temperature and capacitance measurements. This allows you to replace your temperature meter, capacitance meter, counter, continuity tester, and traditional DMM with one versatile instrument, saving bench space and cost. Analyze Your Device with Graphical Display Modes With the unique dual display of the DMM4050/4040, you can measure two different parameters of the same signal from one test connection. To reveal signal quality issues like drift, intermittent transients, and stability, you can view the data as a real-time trend plot or a histogram with the DMM4050/4040’s graphical display mode, or you can use measurement statistics to track how signal parameters are changing over time. TrendPlot™ Paperless Recorder Mode Depending on your test case, your signal parameters may change from instant to instant. By taking multiple measurements over minutes, hours, or days, you can quantify those changes. With TrendPlot™, you can graphically plot the trend of a measured value over time, from short time spans to extended periods of time. TrendPlot can be used with measurements like DC voltage, DC current, frequency, resistance, and temperature. AC voltage and current can be plotted as RMS measurements. A sample of a Min/Max/Avg/SD Statistics Report. Histogram display. Measurement Statistics With integrated statistics processing, you can calculate both the average and standard deviation of a measurement, as well as track the minimum and maximum measured values, with the push of a button. Statistics can be performed on DC voltage, AC voltage, AC voltage in dB, DC current, AC current, resistance, capacitance, frequency, period, and temperature measurements. Histogram Plots To graphically see the average and standard deviation of a set of measurements, you can use the histogram function to see the distribution of measurement results. Designed to Make Your Work Easier The DMM4050/4040 multimeter is designed with the ease of use and familiar operation you expect from Tektronix. Intuitive Operation Dedicated front-panel buttons provide fast access to frequently used functions and parameters, reducing setup time. You no longer need to search through software menus tofind the function you need. Dual Display With the unique dual display, you can measure two different parameters of the same signal from one test connection. Easy Data Storage and PC Connectivity A USB port on the front panel makes it easy to store measurement data and instrument setups to a memory stick. Or connect to your PC with the LAN, RS-232, or GPIB port on the back panel. A USB to RS-232 interface adapter cable is included standard with the DMM4050/4040 to make it easy to connect to your PC’s USB port. Simple and Accurate 4-wire Measurements Patented split terminal jacks for the 2×4 ohms function allow you to perform 4-wire measurements using only two leads instead of four. Special test lead accessories are available to enable you to establish the connection. You get excellent resolution and accuracy plus the convenience and ease of using a single pair of leads. 2 www.tektronix.comdmm

Digital Multimeters — Tektronix DMM4050 and DMM4040 SignalExpress acquiring data from Tektronix DMM4050 and DPO3052. Connect Your Bench for Intelligent Debug Easily capture, save, and analyze measurement results from your multimeter with the special Tektronix Edition of National Instrument’s LabVIEW SignalExpress™ software. Every DMM4050 and DMM4040 ships with a free copy of the Limited Edition version of SignalExpress for basic instrument control, data logging, and analysis. The optional Professional Edition offers over 200 built-in functions that provide additional signal processing, advanced analysis, sweeping, limit testing, and user-defined step capabilities. SignalExpress supports the range of Tektronix bench instruments* enabling you to connect your entire test bench. You can then access the feature-rich tools packed into each instrument from one intuitive software SignalExpress used to export DMM4050 data into Excel. interface. This allows you to automate complex measurements requiring multiple instruments, log data for an extended period of time, time correlate data from multiple instruments, and easily capture and analyze your results, all from your PC. Only Tektronix offers a connected test bench of intelligent instruments to simplify and speed debug of your complex design. Performance You Can Count On In addition to industry-leading service and support, every DMM4050 and DMM4040 multimeter comes backed with a three-year standard warranty. *1 NI LabVIEW SignalExpress supports the following Tektronix instruments: MSO/DPO4000/3000/2000 Series oscilloscopes, TDS3000C/2000B/1000B Series oscilloscopes, AFG3000 Series arbitrary/function generators, DMM4050/4040/4020 Series digital multimeters. www.tektronix.comdmm 3

General Specifications Voltage Characteristic Description

100 V Setting 90 V to 110 V

120 V Setting 108 V to 132 V

220 V Setting 198 V to 242 V

240 V Setting 2 1 6Vt o2 6 4V

Frequency 47 Hz to 440 Hz. Automatically sensed at power-on Power Consumption 28 VA peak (12 Watt average) Dimensions Dimension mm in. Height 88 3.46 Width 217 8.56 Depth 297 11.7 Weight kg lb. Net 3.6 8.0 Shipping 5.0 11.0 Display Vacuum Fluorescent Display, dot matrix Environment Characteristic Description Temperature Operating 0 °C to 55 °C Storage –40 °C to 70 °C Warm Up 1 hour to full uncertainty specifications Relative Humidity (noncondensing) O p e r a t i n g < 9 0 %( 0° Ct o2 8° C ) < 8 0 %( 2 8° Ct o4 0° C ) < 5 0 %( 4 0° Ct o5 5° C ) Storage <95% (–40 °C to 70 °C) Altitude Operating 2,000 meters Storage 12,000 meters Vibration Complies with Mil-T-28800F Type III, Class 5 (Sine only) Safety Designed to comply with IEC 61010-1:2000-1, UL 61010-1A1, CAN/CSA-C22.2 No. 61010.1, CAT I 1000V /C A TI I6 0 0V EMC Designed to comply with IEC 61326-1:2000-11 (EMC) when used with shielded communications cables. This meter has shown susceptibility to radiated frequencies greater than 1 V/m from 250 to 450 MHz Triggering Characteristic Description Samples per Trigger 1t o5 0 , 0 0 0 Trigger Delay 0 s to 3600 s; in 10 μs increments External Trigger Delay <1 ms External Trigger Jitter <500 μs Trigger Input TTL Levels Trigger Output 5 V max (open collector) Memory Model Description DMM4050/4040 10,000 measurements, internal, and up to 2 Gigabyte capacity with USB memory module (available separately) through front-panel USB port Math Functions Zero, dBm, dB, MX+B, Offset, DCV ratio and TrendPlot, Histogram, Statistics (min/max/average/standard deviation), and Limit Test Dual Function Compatibility Matrix Secondary FunctionPrimary Function VDC VAC IDC IAC FREQ OHMS DIODE Period RTD VDC X VAC XX IDC X IAC XX FREQ X OHMS X DIODE Continuity X 4 www.tektronix.comdmm

Digital Multimeters — Tektronix DMM4050 and DMM4040 Electrical Characteristic Description Input Protection 1000 V all ranges Overrange 20% on all ranges except 1000 VDC, 1000 VAC, Diode, and 10 A ranges Remote Interfaces RS-232C, DTE 9-pin, 1200 to 230400 baud (RS-232C to USB cable available to connect the meter to a PC USB port) IEEE 488.2. LAN and “Ethernet 10/100BASE-T with DHCP (for IP address) option”. Warranty Three years Electrical Specifications DC Voltage Specifications Accuracy specifications are valid for 6½ digit resolution mode after at least a 1 hour w a r m - u pw i t hA u t oZ e r oe n a b l e d . 24-hour specifications are relative to calibration standards and assume a controlled electromagnetic environment per EN 61326-1:2000-11. Characteristic Description Maximum Input 1000 V on any range Common Mode Rejection 1 4 0d Ba t5 0o r6 0H z± 0 . 1 %( 1kΩunbalance) Normal ModeRejection 60 dB for NPLC of 1 or greater with analogfilter off and power line frequency ±0.1% 100 dB for NPLC of 1 or greater with analogfilter on and power line frequency ±0.1% Measurement Method Multiramp A/D A/D Linearity 0.0002% of measurement + 0.0001% of range Input Bias Current <30 pA at 25 °C Auto-zero Off Operation Following instrument warm-up at calibration temperature ±1 °C and less than 10 minutes, add error: 0.0002% range additional error +5μV Analog Filter When using the analogfilter, specifications are relative to within one hour of using the ZERO function for that range and NPLC setting DC Ratio Accuracy is ±(Input accuracy + Reference accuracy), where Input accuracy = DC Voltage accuracy for the HI to LO Input (in ppm of the Input voltage), and Reference accuracy = DC Voltage accuracy for the HI to LO (Sense) Reference (in ppm of the Reference voltage) Settling Considerations Measurement settling times are affected by source impedance, cable dielectric characteristics, and input signal changes Input Characteristics ResolutionRange Resolution 4½ Digits 5½ Digits 6½ Digits Input Impedance 100 mV 100.0000 mV 10 μV1 μV 100 nV 10 MΩ or >10 GΩ2 1 V 1.000000 V 100 μV1 0 μV1 μV 10 MΩ or >10 GΩ2 10 V 10.00000 V 1 mV 100 μV1 0 μV 10 MΩ or >10 GΩ2 100 V 100.0000 V 10 mV 1 mV 100 μV 10 MΩ ±1% 1000 V 1,000.000 V 100 mV 10 mV 1 mV 10 MΩ ±1% 2 Inputs beyond ±14 V are clamped through 200 kΩtypical. 10 MΩis default input impedance. www.tektronix.comdmm 5

Accuracy is given as ±(% measurement + % of range) Range 24 Hour (23 °C ±1 °C)

90 Days

( 2 3° C± 5° C ) 1Y e a r (23 °C ±5 °C) Temperature Coefficient/°C O u t s i d e1 8t o2 8° C DMM4040 Accuracy Accuracy is given as ±(% measurement + % of range) Range 24 Hour (23 °C ±1 °C) ( 2 3° C± 5° C ) 1Y e a r (23 °C ±5 °C) Temperature Coefficient/°C O u t s i d e1 8t o2 8° C Additional Errors Digits NPLC Additional NPLC Noise Error 6½ 100 0% of range 6½ 10 0% of range 5½ 1 0.001% of range 5½ 0.2 0.0025% of range ±12μV 4½ 0.02 0.017% of range ±17μV 6 www.tektronix.comdmm

Digital Multimeters — Tektronix DMM4050 and DMM4040 AC Voltage Specifications AC Voltage specifications are for AC sinewave signals >5% of range. For inputs from 1% to 5% of range and <50 kHz, add an additional error of 0.1% of range, and for 50 kHz to 100 kHz, add 0.13% of range. Characteristic Description Maximum Input 1000 V RMS or 1414 V peak or 8 × 107 Volts-Hertz product (whichever is less) for any range Measurement Method AC-coupled true RMS. Measures the AC component of input with up to 1000 VDC bias on any range AC Filter Bandwidth Slow 3 Hz - 300 kHz Medium 20 Hz - 300 kHz Fast 200 Hz - 300 kHz Common Mode Rejection 70 dB at 50 Hz or 60 Hz ±0.1% (1 kΩunbalance) Maximum Crest Factor 5:1 at Full Scale Additional Crest Factor Errors (<100 Hz) Crest factor 1-2, 0.05% of full scale C r e s tf a c t o r2 - 3 ,0 . 2 %o ff u l ls c a l e C r e s tf a c t o r3 - 4 ,0 . 4 %o ff u l ls c a l e C r e s tf a c t o r4 - 5 ,0 . 5 %o ff u l ls c a l e Only applies for non-sinusoid signals Input Characteristics ResolutionRange Resolution 4½ Digits 5½ Digits 6½ Digits Input Impedance 100 mV 100.0000 mV 10 μV1 μV 100 nV 1 V 1.000000 V 100 μV1 0 μV1 μV 10 V 10.00000 V 1 mV 100 μV1 0 μV 100 V 100.0000 V 10 mV 1 mV 100 μV 1000 V 1,000.000 V 100 mV 10 mV 1 mV 1M Ω ±2% shunted by <100 pf www.tektronix.comdmm 7

Accuracy is given as ±(% measurement + % of range) Range Frequency 24 Hour (23 °C ±1 °C) ( 2 3° C± 5° C )

1 Year

( 2 3° C± 5° C ) Temperature Coefficient/°C O u t s i d e1 8t o2 8° C 100 mV 10 V 100 V 1000 V 3 Typically 30% reading error at 1 MHz. 4 1000 Vrange is limited to 8 × 107 Volt-Hertz. Additional Low Frequency Errors E r r o ri ss t a t e da s%o fr e a d i n g . AC FilterFrequency

3 Hz (Slow) 20 Hz (Medium) 200 Hz (Fast)

10 - 20 Hz 0 0.25 — 20 - 40 Hz 0 0.02 — 40 - 100 Hz 0 0.01 0.55 100 - 200 Hz 0 0 0.2 200 Hz - 1 kHz 0 0 0.02 >1 kHz 0 0 0 8 www.tektronix.comdmm

Digital Multimeters — Tektronix DMM4050 and DMM4040 Resistance Specifications are for 4-wire resistance function, 2 × 4-wire resistance, or 2-wire resistance with zero. If zero is not used, add 0.2Ωfor 2-wire resistance plus lead resistance, and add 20 mΩfor 2 × 4-wire resistance function. Characteristic Description Measurement Method Current source referenced to LO input Max Lead Resistance (4-wire ohms) 10% of range per lead for 10Ω, 100Ω,1k Ωranges. 1k Ωper lead on all other ranges Input Protection 1000 V on all ranges Common Mode Rejection 140 dB at 50 or 60 Hz ±0.1% (1 kΩunbalance) Normal Mode Rejection 60 dB for NPLC of 1 or greater with analogfilter off and power line frequency ±0.1% 100 dB for NPLC of 1 or greater with analogfilter on and power line frequency ±0.1% Analog Filter When using the analogfilter, specifications are relative t ow i t h i no n eh o u ro fu s i n gt h eZ E R Of u n c t i o nf o rt h a t range and NPLC setting Input Characteristics ResolutionRange Resolution 4½ Digits 5½ Digits 6½ Digits Source Current 10 Ω 10.00000 Ω 1m Ω 100 μΩ 10 μΩ 5m A/1 3V 100 Ω 100.0000 Ω 10 mΩ 1m Ω 100 μΩ 1m A/6V 1k Ω 1.000000 kΩ 100 mΩ 10 mΩ 1m Ω 1m A/6V 10 kΩ 10.00000 kΩ 1 Ω 100 mΩ 10 mΩ 100 μA/6V 100 kΩ 100.0000 kΩ 10 Ω 1 Ω 100 mΩ 10 μA/1 3V 1M Ω 1.000000 MΩ 100 Ω 10 Ω 1 Ω 10 μA/1 3V 10 MΩ 10.00000 MΩ 1k Ω 100 Ω 10 Ω 1 μA/1 3V 100 MΩ 100.0000 MΩ 10 kΩ 1k Ω 100 Ω 1 μA| |1 0MΩ/1 0V 1.0 GΩ 1.000000 GΩ 100 kΩ 10 kΩ 1k Ω 1 μA| |1 0MΩ/1 0V DMM4050/4040 Accuracy Accuracy is given as ±(% measurement + % of range) Range 24 Hour (23 °C ±1 °C) ( 2 3° C± 5° C ) 1Y e a r (23 °C ±5 °C) Temperature Coefficient/°C O u t s i d e1 8t o2 8° C Additional Ohms Errors Digits NPLC Additional NPLC Noise Error 6½ 100 0% of range 6½ 10 0% of range 5½ 1 0.001% of range 5½ 0.2 0.003% of range ±7 mΩ 4½ 0.02 0.017% of range ±15 mΩ www.tektronix.comdmm 9

Characteristic Description Input Protection Tool-accessible 11 A / 1000 V and 440 mA / 1000 V fuses, limits of 400 mA continuous 550 mA for 2 minutes on, 1 minute off Common Mode Rejection 140 dB at 50 or60 Hz ±0.1% (1 kΩunbalance) Normal Mode Rejection 60 dB for NPLC of 1 or greater with analogfilter off and power line frequency ±0.1% 100 dB for NPLC of 1 or greater with analogfilter on and power line frequency ±0.1% Analog Filter When using the analogfilter, specifications are relative to withino n eh o u ro fu s i n gt h eZ E R Of u n c t i o nf o rt h a t range andNPLC setting Input Characteristics ResolutionRange Resolution 4½ Digits 5½ Digits 6½ Digits Shunt Resistance (Ohms) Burden Voltage 100 μA 100.0000 μA1 0 n A 1 n A 1 0 0 p A 100 Ω <0.015 V 1 mA 1.000000 mA 100 nA 10 nA 1 nA 100 Ω <0.15 V 10 mA 10.00000 mA 1 μA 100 nA 10 nA 1 Ω <0.025 V 100 mA 100.0000 mA 10 μA1 μA 100 nA 1 Ω <0.25 V 400 mA7 400.000 mA 100 μA1 0 μA1 μA 1 Ω <0.50 V 1A 6 1.000000 A 100 μA1 0 μA1 μA 0.01 Ω <0.05 V 3A 5 3.00000 A 1 mA 100 μA1 0 μA 0.01 Ω <0.15 V 10 A 10.00000 A 1 mA 100 μA1 0 μA 0.01 Ω <0.5 V 5 Part of 10 A range. 6 Available on the front-panel terminal only. 7 400 mA continuously; 550 mA for 2 minutes on, 1 minute off. DMM4050/4040 Accuracy Accuracy is given as ±(% measurement + % of range) Range 24 Hour (23 °C ±1 °C) ( 2 3° C± 5° C ) 1Y e a r (23 °C ±5 °C) Temperature Coefficient/°C O u t s i d e1 8t o2 8° C 5 Part of 10 A range. 6 Available on the front-panel terminal only. 7 400 mA continuously; 550 mA for 2 minutes on, 1 minute off. Additional Current Errors Digits NPLC Additional NPLC Noise Error for 1 mA, 100 mA, 400 mA, 3A ,a n d1 0A Additional NPLC Noise Error for 100 μA, 10 mA, 1 A 6½ 100 0% of range 0% of range 6½ 10 0% of range 0% of range 5½ 1 0.001% of range 0.01% of range 5½ 0.2 0.11% of range ±4μA 0.11% of range ±4 μA 4½ 0.02 0.04% of range ±4μA 0.28% of range ±4 μA 10 www.tektronix.comdmm

Digital Multimeters — Tektronix DMM4050 and DMM4040 AC Current The following AC current specifications are for sinusoidal signals with amplitudes greater than 5% of range. For inputs from 1% to 5% of range, add an additional error of 0.1% of range. Characteristic Description Input Protection Tool-accessible 11 A / 1000 V and 440 mA / 1000 V fuses, limits of 400 mA continuous 550 mA for 2 minutes on, 1 minute off Measurement Method AC-coupled true RMS, DC-coupled to the fuse and shunt (no blocking capacitor) AC Filter Bandwidth Slow 3H zt o1 0k H z Medium 20 Hz to 10 kHz Fast 200 Hz to 10 kHz Maximum Crest Factor 5:1 at Full Scale Additional Crest Factor Errors (<100 Hz) Crest factor 1-2, 0.05% of full scale C r e s tf a c t o r2 - 3 ,0 . 2 %o ff u l ls c a l e C r e s tf a c t o r3 - 4 ,0 . 4 %o ff u l ls c a l e C r e s tf a c t o r4 - 5 ,0 . 5 %o ff u l ls c a l e Only applies to non-sinusoid signals Input Characteristics ResolutionRange Resolution 4½ Digits 5½ Digits 6½ Digits Shunt Resistance (Ohms) Burden Voltage 100 μA 100.0000 μA1 0 n A 1 n A 1 0 0 p A 100 Ω <0.015 V 1 mA 1.000000 mA 100 nA 10 nA 1 nA 100 Ω <0.15 V 10 mA 10.00000 mA 1 μA 100 nA 10 nA 1 Ω <0.025 V 100 mA 100.0000 mA 10 μA1 μA 100 nA 1 Ω <0.25 V 400 mA9 400.000 mA 100 μA1 0 μA1 μA 1 Ω <0.50 V 1A 8 1.000000 A 100 μA1 0 μA1 μA 0.01 Ω <0.05 V 3A 5, 8 3.00000 A 1 mA 100 μA1 0 μA 0.01 Ω <0.05 V 10 A8 10.00000 A 1 mA 100 μA1 0 μA 0.01 Ω <0.5 V 5 Part of 10 A range. 8 Available at front-panel connectors only. 9 400 mA continuously; 550 mA for 2 minutes on, 1 minute off; maximum crest factor 3:1 at 400 mA. www.tektronix.comdmm 11

Accuracy is given as ±(% measurement + % of range) Range Frequency 24 Hour (23 °C ±1 °C) ( 2 3° C± 5° C ) ( 2 3° C± 5° C ) Temperature Coefficient/°C O u t s i d e1 8t o2 8° C 100 μA 1m A 10 mA 100 mA 400 mA7 1A 6 3A 5, 6 10 A6 5 Part of 10 A range. 6 Available on the front-panel terminal only. 7 400 mA continuously; 550 mA for 2 minutes on, 1 minute off. Additional Low-frequency Errors E r r o ri ss t a t e da s%o fr e a d i n g . AC FilterFrequency 10 - 20 Hz 0 0.25 — 20 - 40 Hz 0 0.02 — 40 - 100 Hz 0 0.01 0.55 100 - 200 Hz 0 0 0.2 200 Hz - 1 kHz 0 0 0.02 >1 kHz 0 0 0 12 www.tektronix.comdmm

Digital Multimeters — Tektronix DMM4050 and DMM4040 Frequency Characteristic Description Gate Time Programmable to 1 s, 100 ms, and 10 ms Measurement Method Flexible counting technique. AC-coupled input using the AC voltage measurement function Settling Considerations When measuring frequency or period after a DC offset voltage change, errors may occur. For the most accurate measurement, wait up to 1 second for the input blocking capacitor to settle Measurement Considerations To minimize measurement errors, shield inputs from external noise when measuring low-voltage, low-frequency signals DMM4050/4040 Accuracy Accuracy is given as ± % measurement Range Frequency 24 Hour (23 °C ±1 °C) ( 2 3° C± 5° C ) ( 2 3° C± 5° C ) Temperature Coefficient/°C O u t s i d e1 8t o2 8° C 3-5H z 0 . 1 0 . 1 0 . 1 0 . 0 0 5 5 - 10 Hz 0.05 0.05 0.05 0.005 10 - 40 Hz 0.03 0.03 0.03 0.001 40 Hz - 300 kHz 0.006 0.01 0.01 0.001 100 mV to 1000 V10, 11 300 kHz - 1 MHz 0.006 0.01 0.01 0.001

10 L i m i t e dt o8×1 07 Volt-Hertz

11 Input >100 mV. For 10 - 100 mV, multiply percent measurement error by 10. Gate Time vs. Resolution Gate Time Resolution 0.01 5½ 0.1 6½ 1.0 6½ Additional Low-frequency Errors Error stated as percent of measurement for inputs >100 mV. For 10 - 100 mV, multiply percent by 10. NPLCFrequency 6½ 5½ 4½ 3 - 5 Hz 0 0.12 0.12 5 - 10 Hz 0 0.17 0.17 10 - 40 Hz 0 0.2 0.2 40 - 100 Hz 0 0.06 0.21 100 - 300 Hz 0 0.03 0.21 3 0 0H z-1k H z 0 0 . 0 1 0 . 0 7 >1 kHz 0 0 0.02 www.tektronix.comdmm 13

Capacitance (DMM4050 Only) Accuracy is stated as ±(% of measurement + % of range) Range Resolution 1 Year Accuracy 12 (23 °C ±5 °C) Temperature Coefficient/°C O u t s i d e1 8t o2 8° C 1n F 1p F 2% ±2.5% 0.05 + 0.05 10 nF 10 pF 1% ±0.5% 0.05 + 0.01 100 nF 100 pF 1% ±0.5% 0.01 + 0.01 1 μF1 n F 1% ±0.5% 0.01 + 0.01 10 μF1 0 n F 1% ±0.5% 0.01 + 0.01 100 μF1 0 0 n F 1% ±0.5% 0.01 + 0.01 1m F 1 μF 1% ±0.5% 0.01 + 0.01 10 mF 10 μF 1% ±0.5% 0.01 + 0.01 100 mF 100 μF 4% ±0.2% 0.05 + 0.05 12 Stated accuracy is attained when Zero function is used. Temperature (DMM4050 only) Test Current: 1 mA Accuracy is stated as ± °C and is based on a Platinum RT100 (DIN IEC 751, 385 type) RTD with less than 10Ωlead resistance. The accuracy list e di nt h et a b l eb e l o wa r ev a l i d only when using the 4-wire RTD measurement function. Specifications do not include probe accuracy, which must be added. AccuracyRange Resolution ( 2 3° C± 5° C ) 1Y e a r (23 °C ±5 °C) TemperatureC o e fficient/°C Outside 18to 28 °C –200 °C 0.001 °C 0.06 0.09 0.0025 –100 °C 0.001 °C 0.05 0.08 0.002 0 °C 0.001 °C 0.04 0.06 0.002 100 °C 0.001 °C 0.05 0.08 0.002 300 °C 0.001 °C 0.1 0.12 0.002 600 °C 0.001 °C 0.18 0.22 0.002 Additional Errors Digits NPLC Additional NPLC Noise Error 6½ 100 0° C 6½ 10 0° C 5½ 1 0.03 °C 5½ 0.2 0.12 °C 4½ 0.02 0.6 °C 14 www.tektronix.comdmm

Digital Multimeters — Tektronix DMM4050 and DMM4040 Continuity Characteristic Description Continuity Threshold Selectable between 1 Ωand 1000Ω Test Current 1m A Response Time 300 S/s with audible tone Accuracy is given as ±(% measurements + % of range) Range 24 Hour (23 °C ±1 °C) (23 °C ±5 °C) ( 2 3° C± 5° C ) Temperature Coefficient/°C Outside 18 to 28 °C Diode Test Characteristic Description Test Current 100 μAo r1m A Response Time 300 S/s with audible tone Accuracy is given as ±(% measurements + % of range) Range 24 Hour ( 2 3° C± 1° C ) (23 °C ±5 °C) ( 2 3° C± 5° C ) Temperature Coefficient/°C Outside 18 to 28 °C Measurement Rates (IEEE48816) Measurements/Second13Function Digits Setting Integration Time

60 Hz (50 Hz) DMM4040 DMM4050

6½ 10 NPLC 167 (200) ms 6 (5) 6 (5) 5½ 1 NPLC 16.7 (20) ms 60 (50) 60 (50) 5½ 0.2 NPLC 3.3 ms 270 270 DC Volts, DC Current, and Resistance 4½ 0.02 NPLC 500 μs 995 995 6½ 3H z 0 . 4 7 0 . 4 7 6½ 20 Hz 1.64 1.64 AC Voltage and AC Current14 6½ 200 Hz15 4.5 4.5 6½ 1s 1 1 5½ 100 ms 9.8 9.8 Frequency and Period 4½ 10 ms 80 80 Capacitance 6½ NA 2 13 Typical measurement rates with auto-zero off, delay = 0, display off, auto range off and math off. 14 Maximum measurement rates for 0.01% of AC step. When DC input varies, additional settling delay is required. 15 For remote operation or external trigger using default settling delay. 16 Note that the measurement rates for RS232 can vary depending on the baud rate chosen. If the baud rate selected is 115,200, the maximum measurement rate is 711 measurements. The LAN bus has a maximum measurement rate of 963 measurements. www.tektronix.comdmm 15

Ordering Information

DMM4040 6.5 Digit Multimeter DMM4050 6.5 Digit Multimeter DMM4050/4040 Includes: Meter, TL710 Test Leads, Line Cord, Calibration Certificate, Calibration Data Report, Safety and Installation Instructions including Warranty Statement, CD-ROM with User Manual (English, French, Italian, German, Spanish, Simplified Chinese, Traditional Chinese, Korean, Russian, Japanese) and Connectivity Information, RS-232 to USB Adapter Cable, National Instruments LabVIEW SignalExpress™ Tektronix Edition Limited Edition Software. Please specify power plug when ordering. Instrument Options Power Plug Options Option Description Opt. A0 North America Opt. A1 Universal Euro Opt. A2 United Kingdom Opt. A3 Australia Opt. A5 Switzerland Opt. A6 Japan Opt. A10 China Opt. A11 India Opt. A12 Brazil Opt. E1 Euro and UK power cords Service Options*17 Option Description Opt. CA1 Single Calibration or Functional Veri fication Opt. R5 Repair Service 5 Years (including warranty) Opt. SILV100 Standard Warranty Extended to 5 Years *17 Test Leads and accessories are not covered by the DMM warranty and Service Offerings. Refer to the datasheet of each Test Lead and accessory model for its unique warranty and calibration terms. Recommended Accessories and Software Accessory Description Calibration Manual 077-0362-xx Programmer's Manual 077-0363-xx TP750 100 ΩRTD Temperature Probe (DMM4050 only) 196-3520-xx Premium Test Leads (replacement/spare for TL710) TL705 2×4 Wire Ohm 1000 V Precision Test Lead TL725 2×4 Wire Ohm SMD Test Tweezers ACD4000 Soft Transit Case HCTEK4321 Hard Carrying Case RMU2U Rackmount Shelf Kit for 1 or 2 Units 013-0369-xx Calibration Fixture 4-terminal short 196-3520-00 TL710 Premium Test Lead SIGEXPTE NI LabVIEW SignalExpress Tektronix Edition Software – Full Version Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. Product(s) complies with IEEE Standard 488.1-1987 and RS-232C. 16 www.tektronix.comdmm

Digital Multimeters — Tektronix DMM4050 and DMM4040 www.tektronix.comdmm 17

18 www.tektronix.comdmm

Digital Multimeters — Tektronix DMM4050 and DMM4040 www.tektronix.comdmm 19

Datasheet Contact Tektronix: ASEAN / Australasia (65) 6356 3900 Austria 00800 2255 4835* Balkans, Israel, South Africa and other ISE Countries+41 52 675 3777 Belgium 00800 2255 4835* Brazil + 5 5( 1 1 )3 7 5 97 6 2 7 Canada 1 800 833 9200 Central East Europe and the Baltics+ 4 15 26 7 53 7 7 7 Central Europe & Greece+41 52 675 3777 Denmark + 4 58 08 81 4 0 1 Finland + 4 15 2675 3777 France 00800 2255 4835* Germany 00800 2255 4835* Hong Kong400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835* Japan 81 (3) 6714 3010 Luxembourg + 4 15 26 7 53 7 7 7 Mexico, Central/South America & Caribbean52 (55) 56 04 50 90 Middle East,Asia, and North Africa+41 52 675 3777 The Netherlands00800 2255 4835* Norway 800 16098 People’s Republic of China400 820 5835 Poland +41 52 675 3777 Portugal 80 08 12370 Republic ofKorea 001 800 8255 2835 Russia & CIS+7 (495) 6647564 South Africa+ 4 15 26 7 53 7 7 7 Spain 00800 2255 4835* Sweden 00800 2255 4835* Switzerland 00800 2255 4835* Taiwan 886 (2) 2722 9622 United Kingdom & Ireland00800 2255 4835* USA 1 800 833 9200 * European toll-free number. If not accessible, call: +41 52 675 3777 Updated 10 February 2011 For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visitwww.tektronix.com Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies.