PS-TNDR GREYSTONE | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM RIGID DUCT AVERAGE NETWORK TEMPERATURE SENSOR TNDR SERIES CABLE GLAND FITTING THREAD ADAPTER 1/2” NPT TO M16 ACCESSORIES - INCLUDED WITH E ENCLOSURE OPTION PRODUCT DESCRIPTION The multi point rigid duct average network temperature sensor incorporates numerous precision sensors at equal distances and encapsulated in a 6 mm (0.236”) OD, 304 series stainless steel probe and is available in various lengths. All probes provide excellent heat transfer, fast response and resist moisture penetration. The transmitter provides a BACnet® or Modbus signal for network connection. A compact ABS enclosure with a hinged and gasketed cover is provided for ease of installation. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. The rigid duct average type probes are installed in the side of the duct to monitor the average temperature within the duct. Select a probe length that allows the probe to span the duct width. Install the probe in a straight section of duct at a suitable distance downstream from any heating, cooling, or humidification devices. The enclosure provides mounting tabs for ease of installation. POWER SUPPLY BACnet®: 24 Vac/dc ±10% (non-isolated half-wave rectified) Modbus: 24 Vac/dc ±20% (non-isolated half-wave rectified) CONSUMPTION BACnet®: 25 mA max @ 24 Vdc Modbus: 10 mA max @ 24 Vdc OPERATING ENVIRONMENT -40 to 50°C (-40 to 122°F), 5 to 95 %RH non-condensing PROBE MATERIAL 304 series stainless steel PROBE DIAMETER 6mm (0.236”) STANDARD LENGTHS 450mm, 600mm, 900mm (18” , 24” , 36”) WIRE MATERIAL PVC insulated, parllel bonded (22 AWG) WIRING CONNECTIONS Screw terminal block (14 to 22 AWG) ENCLOSURE A: ABS, UL94-V0, IP65 (NEMA 4X) E: Same as A, with thread adapter (1/2” NPT to M16) and cable gland fitting COUNTRY OF ORIGIN Canada TEMPERATURE Sensing Element: NTC thermistor Accuracy: ±0.2°C (±0.36°F) @ 0 to 70°C (32 to 158°F) Probe Sensing Range: -40 to 60°C (-40 to 140°F) Resolution: 0.1°C/°F BACnet® COMMUNICATIONS INTERFACE Hardware: 2 wire RS-485 Software: Native BACnet® MS/TP protocol Baud Rate: 9600, 19200, 38400, 57600, 76800, or 115200 (auto-detect) Network Address Range: Locally set to 0-127 Serial Configuration: 8N1 MODBUS COMMUNICATIONS INTERFACE Hardware: 2 wire RS-485 Software: Native Modbus MS/TP protocol (RTU) Baud Rate: 9600, 19200, 38400, 57600, 76800, or 115200 (auto-detect) Network Address Range: Locally set to 1-255 (switch selectable) Parity: None Stop Bits: 1 Error Checking: A001 (CRC-16 reverse) INPUT VOLTAGE EFFECT Negligible over specified operating range PROTECTION CIRCUIRTY Reverse voltage protected and transient protected SPECIFICATIONS 82.5 mm 3.25" 69.8 mm 2.75" Various Probe Lengths See Specifications 6 mm (0.236") 76.2 mm 3.00" 0.5" NPT Foam Gasket

304 Series S/S Probe

52.0 mm 2.05"

PRINTED IN CANADA Copyright © Greystone Energy Systems Inc. All Rights Reserved www.greystoneenergy.com PS-TNDRXXX-03 Greystone Energy Systems, Inc.

150 English Drive, Moncton,

New Brunswick, Canada E1E 4G7 Ph: +1 (506) 853-3057 Fax: +1 (506) 853-6014 North America: 1-800-561-5611 E-mail: mail@greystoneenergy.com PRODUCT TNDR Rigid Duct Average Network Temperature Sensor ENCLOSURE A E ABS, with hinged and gasketed cover Same as A, with thread adapter (1/2” NPT to M16) and cable gland fitting SENSOR 20 NTC Thermistor, ±0.2°C PROBE LENGTH F G H 450mm (18”) 600mm (24”) 900mm (36”) COMMUNICATION OUTPUT B M BACnet® Modbus ORDERING TNDR PART NUMBER NOTE: Greystone Energy Systems, Inc. reserves the right to make design modifications without prior notice. BACnet® COMMUNICATION BACnet® is a data communication protocol for building automation and control networks. The sensor communicates on a standard 2-wire RS-485 MS/TP network designed to run at speeds from 9600 to 115200 baud over twisted pair wiring. BACnet® is a registered trademark of ASHRAE. ASHRAE does not endorse, approve or test products for compliance with ASHRAE standards. Compliance of BACnet® listed products to the requirements of ASHRAE Standard 135 is the responsibility of BACnet® International (BI). BTL is a registered trademark of BI. MODBUS COMMUNICATION Modbus is a network protocol for industrial manufacturing environments. The sensor communicates on a standard Modbus network using the RTU (Remote Terminal Unit) transmission mode. The hardware interface is RS-485.