GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM FLEX-DUCT AVERAGE NETWORK TEMPERATURE SENSOR TNDF SERIES PRODUCT DESCRIPTION The flexible, multi point duct average network temperature sensor incorporates numerous precision sensors at equal distances across the FT-6 plenum rated cable and is available in various lengths. All probes provide excellent heat transfer, fast response and resist moisture penetration. The transmitter provides a BACnet® or Modbus signal for network connection. A compact ABS enclosure with a hinged and gasketed cover is provided for ease of installation. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. The flex-duct average probes are installed through a hole in the side of the duct to monitor an average temperature within the duct. Select a probe length that allows for criss-crossing the duct multiple times. Install the probes in a straight section of duct at a suitable distance downstream from any heating, cooling, or humidification devices. The cable probe needs to be fastened onto hangers using tube clamps or wire ties and should be secured every 100 cm or 3’ maximum to prevent movement of the wire and prevent wear. If sensor is to be used in high velocity or vibration environment use of rigid style duct probe is recommended. The enclosure provides mounting tabs for ease of installation. NOTE: This product is factory calibrated and any field adjustment will void the warranty. POWER SUPPLY BACnet®: 24 Vac/dc ±10% (non-isolated half-wave rectified) Modbus: 24 Vac/dc ±20% (non-isolated half-wave rectified) CONSUMPTION BACnet®: 25 mA max @ 24 Vdc Modbus: 10 mA max @ 24 Vdc OUTPUT SIGNAL MS/TP 2-wire RS-485 (BACnet® or Modbus) OPERATING ENVIRONMENT -40 to 50°C (-40 to 122°F), 5 to 95 %RH non-condensing STANDARD LENGTHS 1800mm, 3600mm, 6100mm, 7300mm (6’ , 12’ , 20’ , 24’) PROBE SENSING RANGE -20 to 60°C (-4 to 140°F) WIRE MATERIAL FT-6 plenum rated cable, 22 AWG WIRING CONNECTIONS Screw terminal block (14 to 22 AWG) ENCLOSURE A: ABS, UL94-V0, IP65 (NEMA 4X) E: Same as A, with thread adapter (1/2” NPT to M16) and cable gland fitting COUNTRY OF ORIGIN Canada TEMPERATURE Sensing Element: NTC thermistor Accuracy: ±0.2°C (±0.36°F) @ 0 to 70°C (32 to 158°F) Resolution: 0.1°C/°F BACnet® COMMUNICATIONS INTERFACE Hardware: 2 wire RS-485 Software: Native BACnet® MS/TP protocol Baud Rate: 9600, 19200, 38400, 57600, 76800, or 115200 (auto-detect) Network Address Range: Locally set to 0-127 Serial Configuration: 8N1 MODBUS COMMUNICATIONS INTERFACE Hardware: 2 wire RS-485 Software: Native Modbus MS/TP protocol (RTU) Baud Rate: 9600, 19200, 38400, 57600, 76800, or 115200 (auto-detect) Network Address Range: Locally set to 1-255 (switch selectable) Parity: None Stop Bits: 1 Error Checking: A001 (CRC-16 reverse) INPUT VOLTAGE EFFECT Negligible over specified operating range PROTECTION CIRCUITRY Reverse voltage protected and transient protected. SPECIFICATIONS 82.5 mm 3.25" 69.8 mm 2.75" 52.0 mm 2.05" 76.2 mm 3.00" 0.5” NPT Foam Gasket
304 Series S/S Probe
CABLE GLAND FITTING THREAD ADAPTER 1/2” NPT TO M16 ACCESSORIES - INCLUDED WITH E ENCLOSURE OPTION
PRINTED IN CANADA Copyright © Greystone Energy Systems Inc. All Rights Reserved www.greystoneenergy.com PS-TNDFXXX-03 Greystone Energy Systems, Inc.
150 English Drive, Moncton,
New Brunswick, Canada E1E 4G7 Ph: +1 (506) 853-3057 Fax: +1 (506) 853-6014 North America: 1-800-561-5611 E-mail: mail@greystoneenergy.com PRODUCT TNDF Flexible Cable Duct Average Temperature Sensor ENCLOSURE A E ABS, with hinged and gasketed cover Same as A, with thread adapter and cable gland fitting SENSOR 20 NTC Thermistor, ±0.2°C PROBE LENGTH I J K L 1800mm (6’) (4 sensors) 3600mm (12’) (4 sensors) 6100mm (20’) (4 sensors) 7300mm (24’) (9 sensors) COMMUNICATION OUTPUT B M BACnet® Modbus ORDERING TNDF PART NUMBER NOTE: Greystone Energy Systems, Inc. reserves the right to make design modifications without prior notice. BACnet® COMMUNICATION BACnet® is a data communication protocol for building automation and control networks. The sensor communicates on a standard 2-wire RS-485 MS/TP network designed to run at speeds from 9600 to 115200 baud over twisted pair wiring. BACnet® is a registered trademark of ASHRAE. ASHRAE does not endorse, approve or test products for compliance with ASHRAE standards. Compliance of BACnet® listed products to the requirements of ASHRAE Standard 135 is the responsibility of BACnet® International (BI). BTL is a registered trademark of BI. MODBUS COMMUNICATION Modbus is a network protocol for industrial manufacturing environments. The sensor communicates on a standard Modbus network using the RTU (Remote Terminal Unit) transmission mode. The hardware interface is RS-485.