TMC40 TRUMPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

DESCRIPTION

The TMC40 series of compact, open PCB constructed, AC-DC switching power supplies are capable of delivering 30-48 watts of continuous output power at convection cooling. They operate at 90-264 VAC input voltage without the need of voltage selection, and are suited for medical, information technology and industrial applications. Approval to both EN60601-1 and EN60950-1 safety standards improves design-in time and reduces end equipment compliance costs.

FEATURES

z Medical and ITE approvals z Compact size 2” x4” x1.18” z Single, dual and triple outputs z Full-range input 90-264 VAC z Low earth leakage current z Level B emissions z RoHS compliant INPUT SPECIFICATIONS Input voltage: Input frequency: Input current: Earth Leakage current: 90-264 VAC 47-63 Hz

0.9 A (rms) for 100 VAC

0.5 A (rms) for 240 VAC

150 µA max. @ 264 VAC, 63 Hz OUTPUT SPECIFICATIONS Output voltage/current: See rating chart Maximum output power: See rating chart Ripple and noise: 2% peak to peak on 5.0 V model, 1% peak to peak on other models. Overvoltage protection: Provided on output #1 only; set at 112–132% of its nominal output voltage Overcurrent protection: All outputs protected to short circuit conditions Temperature coefficient: All outputs ±0.04% /°C maximum Transient response: Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 µs after a 25% step load change ENVIRONMENTAL SPECIFICATIONS Operating temperature: Storage temperature: Relative humidity: Derating: -10 o C to +70 o C -40 o C to +85 o C 5% to 95% non-condensing Derate from 100% to +50 o C linearly to 50% at +70 o C SAFETY STANDARD APPROVALS 62±5 KHz 80-88% typical except TMC40-T31-3 and TMC40-T31-5 at 75% typical TMC40 SERIES UL 2601-1 CSA C22.2 No. 601.1 TÜV EN60601-1 Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com TRUMPower 30-48 WATT MEDICAL & ITE SWITCHING POWER SUPPLIES Switching frequency: 62±5 KHz Efficiency: 80-88% typical except TMC40-T31-3 and TMC40-T31-5 at 75% typical Hold-up time: 12 msec minimum at 110 VAC Line regulation: ±0.5% maximum at full load Inrush current: 25 A @ 115 VAC, or 50 A @ 230 VAC, at 25 o C cold start Withstand voltage: 4000 VAC from input to output

1500 VAC from input to ground

500 VAC from output to ground

MTBF: 400,000 hours at full load at 25 o C ambient, calculated per MIL-HDBK-217F EMC Performance EN55011 / EN55022: Class B conducted, class B radiated FCC: Class B conducted, class B radiated VCCI: Class B conducted, class B radiated EN61000-3-2: Harmonic distortion, class A and D EN61000-3-3: Line flicker EN61000-4-2: ESD, ±8 KV air and ±6 KV contact EN61000-4-3: Radiated immunity, 3 V/m EN61000-4-4: Fast transient/burst, ±2 KV EN61000-4-5: Surge, ±1 KV diff., ±2 KV com. EN61000-4-6: Conducted immunity, 3 Vrms EN61000-4-8: Magnetic field immunity, 3 A/m EN61000-4-11: Voltage dips, 30% reduction for 500 ms 60% reduction for 100 ms >95% reduction for 10 ms GENERAL SPECIFICATIONS

OUTPUT VOLTAGE/CURRENT RATING CHART Maximum Output #1 Output #2 Output #3 Output TMC40-S05 5 V 0 A 8.0 A 2% (N/A) (N/A) 40 W TMC40-S12 12 V 0 A 3.5 A 2% (N/A) (N/A) 42 W TMC40-S15 15 V 0 A 3.0 A 2% (N/A) (N/A) 45 W TMC40-S24 24 V 0 A 2.0 A 2% (N/A) (N/A) 48 W TMC40-S48 48 V 0 A 1.0 A 2% (N/A) (N/A) 48 W TMC40-D23 +5 V 0.5 A 6 A 3% +12 V 0.1 A 2 A 5% (N/A) 40 W TMC40-D25 +5 V 0.5 A 6 A 3% +24 V 0.1 A 1 A 5% (N/A) 40 W TMC40-T31 +5 V 0.5 A 6 A 3% +12 V 0.1 A 2 A 5% -12 V 0 A 0.3 A 4% 40 W TMC40-T31-3 +3.3 V 0.8 A 6 A 3% +5 V 0.1 A 2 A 5% +12 V 0 A 0.3 A 4% 30 W TMC40-T31-5 +5 V 0.5 A 6 A 3% +3.3 V 0 A 1.5 A 5% +12 V 0 A 0.3 A 4% 30 W TMC40-T32 +5 V 0.5 A 6 A 3% +15 V 0.1 A 1.5 A 5% -15 V 0 A 0.3 A 4% 40 W TMC40-T39 +5 V 0.5 A 6 A 3% +24 V 0.1 A 1 A 5% -12 V 0 A 0.3 A 4% 40 W NOTE: 1. Safety approvals are for PCB form only. To order unit with cover fitted, add suffix “C”. MECHANICAL SPECIFICATIONS NOTES: 1. Dimensions shown in inches [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal. 4. Output connector mates with Moles housing 09-50-3061 and Moles 2878 series crimp terminal. 6. To ensure compliance with level B emissions, connect the two “*” marked mounting holes with metallic standoffs to chassis. Weight: 205 grams (0.45 lbs.) approx. PIN CHART 1 2 3 4 5 6 TMC40-S05 TMC40-S24 TMC40-S12 TMC40-S48 TMC40-S15 +V1 +V1 RTN RTN N.C N.C TMC40-D23 TMC40-D25 +V1 +V1 RTN RTN N.C +V2 TMC40-T31 TMC40-T32 TMC40-T39 +V1 +V1 RTN RTN -V3 +V2 TMC40-T31-3 ,TMC40-T31-5 +V1 +V1 RTN RTN +V3 +V2 PIN MODEL Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com U N I V E R S A L I N P U T TMC40 MEDICAL & ITE SERIES