DESCRIPTION

The TMC100 series of compact, open PCB constructed, AC-DC switching power supplies are capable of delivering 100 watts of continuous output power at convection. They operate at 90-264 VAC input voltage without the need of voltage selection, and are suited for medical, information technology and industrial applications. Approval to both EN 60601-1 and EN 60950-1 safety standards improves design-in time and reduces end equipment compliance costs.

FEATURES

z Medical and ITE approvals z Compact size 2” × 4” × 1.26” z Ultra high power density 10 W/cubic inch z Full range input 90-132 VAC, or 180-264 VAC z Low earth leakage current z Conducted EMI class B z RoHS compliant INPUT SPECIFICATIONS Input voltage: Input frequency: Input current: Earth leakage current: 90-132 VAC or 180-264 VAC 47-63 Hz 1.9A (rms) for 100-120 VAC 1.0A (rms) for 200-240 VAC 150 µA max. @ 264 VAC, 63 Hz OUTPUT SPECIFICATIONS Output voltage/current: See rating chart Total output power: 100 watts maximum Ripple and noise: 250 mV peak to peak on 5.0 V model , 1% peak to peak on other models. Overvoltage protection: Provided on output; set at 110-140% of its nominal output voltage Overcurrent protection: All outputs protected to short circuit conditions Temperature coefficient: All outputs ±0.04% / o C maximum Transient response: Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 µs after a 25% step load change ENVIRONMENTAL SPECIFICATIONS Operating temperature: Storage temperature: Relative humidity: Derating: Cooling: -10 o C to +70 o C -40 o C to +85 o C 5% to 95% non-condensing Derate from 100% at +50 o C linearly to 50% at +70 o C Convection cooling SAFETY STANDARD APPROVALS GENERAL SPECIFICATIONS Switching frequency: 100 KHz Efficiency: 87-90% @ 230 VAC full load. Hold-up time: 12 msec minimum at 110 VAC. Line regulation: ±0.2% maximum at full load Inrush current: 40 A @ 115 VAC or 80 A @ 230 VAC, at 25 o C cold start Withstand voltage: 4000 VAC from input to output

1500 VAC from input to ground

500 VAC from output to ground

MTBF: 270,000 hours at full load at 25 o C ambient temperature, calculated per MIL-HDBK-217F EMC Performance EN55011 / EN55022: Class B conducted, class A radiated FCC: Class B conducted, class A radiated VCC: Class B conducted, class A radiated EN61000-3-2: Harmonic distortion, class A EN61000-3-3: Line flicker EN61000-4-2: ESD, ±8 KV air and ±6 KV contact EN61000-4-3: Radiated immunity, 3 V/m EN61000-4-4: Fast transient/burst, ±2 KV EN61000-4-5: Surge, ±1 KV diff., ±2 KV com. EN61000-4-6: Conducted immunity, 3 Vrms EN61000-4-8: Magnetic field immunity, 3 A/m EN61000-4-11: Voltage dips, 30% reduction for 500 ms 60% reduction for 100 ms >95% reduction for 5 sec. Performance criteria A, B, A. TMC100 SERIES

100 WATT MEDICAL & ITE SWITCHING POWER SUPPLIES TRUMPower

CSA C22.2 No. 601.1 TÜV EN60601-1 Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com

OUTPUT VOLTAGE/CURRENT RATING CHART O u t p u t P/N Vnom. Imin. Imax. Tol. Maximum Output Power TMC100-S05 5 V 0 A 20 A 2% 100 W TMC100-S12 12 V 0 A 8.34 A 2% 100 W TMC100-S15 15 V 0 A 6.7 A 2% 100 W TMC100-S18 18 V 0 A 5.56 A 2% 100 W TMC100-S24 24 V 0 A 4.2 A 2% 100 W TMC100-S28 28 V 0 A 3.58 A 2% 100 W TMC100-S36 36 V 0 A 2.78 A 2% 100 W TMC100-S48 48 V 0 A 2.1 A 2% 100 W NOTES: 1. Safety approvals are for PCB form only. To order unit with cover fitted, add suffix “C”. MECHANICAL SPECIFICATIONS NOTES: 1. Dimensions shown in inches [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal. 4. Output connector mates with Molex housing 09-50-3061 and Molex 2878 series crimp terminal. 5. To ensure compliance with level B emissions, connect the three “* “ marked mounting holes with metallic standoffs to chassis. 6. Weight: 190 grams (0.44 lbs.) approx. PIN CHART 1 2 3 4 5 6 TMC100-S05 TMC100-S12 TMC100-S15 TMC100-S18 TMC100-S24 TMC100-S28 TMC100-S36 TMC100-S48 RETURN RETURN RETURN OUTPUT OUTPUT OUTPUT PIN MODEL UNIVERSAL INPUT TMC100 MEDICAL & ITE SERIES Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com