DESCRIPTION

The TM201 series comprising single and multiple output models for 150 to 200 watts of continuous output power is specially designed for dental and medical applications. They operate at 90 to 264VAC input voltage without the need of a selector strap. All auxiliary outputs are with magnetic amplifier linear regulator to keep regulation. The units are constructed on a printed circuit board with a U-bracket for mechanical support and heat sinking. A cover-and-fan assembly can be added during manufacturing. TM201 SERIES

FEATURES

‧ Low safety ground leakage current ‧ Meet EN 55011 and FCC Class B ‧ Power Factor 0.98 typical ‧ Short-circuit protection ‧ Power Fail Detect ( PFD ) signal ‧ 100% burn-in at full rated load ‧ Optional cover-and-fan assembly ‧ Remote inhibit - TTL high disables output ‧ Compliant with RoHS requirements Safety Standard Approvals: INPUT SPECIFICATIONS Input voltage : 90 to 264VAC Input frequency : 47 to 63Hz Input current : 3.2A ( rms ) for 115VAC 1.6A ( rms ) for 230VAC Earth leakage current : OUTPUT SPECIFICATIONS Output voltage/current : See rating chart Total output power : 200 watts maximum Ripple and noise : 2% peak to peak maximum Overvoltage protection : Provided on output #1 only; set at 112-132% of its nominal output voltage Overcurrent protection : All outputs protected to short circuit conditions Temperature coefficient : All outputs ±0.04/ºC maximum Transient response : Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500µs after a 25% step load change PFD signal : TTL logic high for normal operation and TTL logic low upon loss of input power. This signal appears at least 1ms prior to +5V output dropping 5% below its nominal value. This signal also provides a minimum delay of 100ms after +5V is within regulation. GENERAL SPECIFICATIONS Switching frequency : 88 KHz –112 KHz Efficiency : 70% minimum on all models Hold-up time : 20 msec minimum at 110VAC Line regulation : ±0.5% maximum at full load Inrush current : 20 amps @ 115VAC or 40 amps @ 230VAC, at 25ºC cold start Withstand voltage : 4000VAC from input to output 1500VAC from input to ground 500VAC from output to ground MTBF : 350,000 hours at full load at 25ºC ambient, calculated per MIL-HDBK-217F EMC Performance (EN60601-1-2: 2001) EN55011: Class B conducted, Class B radiated EN61000-3-2: Harmonic distortion, Class A and D EN61000-3-3: Line flicker EN61000-4-2: ESD, ±8KV air and ±6KV contact EN61000-4-3: Radiated immunity, 3V/m EN61000-4-4: Fast transient/burst, ±2KV EN61000-4-5: Surge, ±1KV diff, ±2KV com. EN61000-4-6: Conducted immunity, 3Vrms EN61000-4-8: Magnetic field immunity, 3A/m EN61000-4-11: Voltage dips, 30% reduction for 500ms, 60% reduction for 100ms and >95% reduction for 10ms UL 60601-1 CSA C22.2 No. 601.1 TÜV EN60601-1 (LVD) ENVIRONMENTAL SPECIFICATIONS Operating temperature: 0ºC to +70ºC Storage temperature: -40ºC to +85ºC Relative humidity: 5% to 95% non-condensing Derating: Derate from 100% at +50ºC linearly to 50% at +70ºC Cooling: 10.8 CFM forced air provided on “C” version; 25 CFM forced air to be provided for U-bracket version by user. 90µA max. @ 115VAC, 60Hz 150µA max. @ 230VAC, 50Hz RoHS TRUMPower 150- 200 WATT MEDICAL POWER SUPPLIES Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com

OUTPUT VOLTAGE/CURRENT RATING CHART Maximum Output #1 Output #2 Output #3 Output #4 Output TM201-S5.1 5.1V 3.0A 35A 2% (N/A) (N/A) (N/A) 175W TM201-S3.3 3.3V 3.0A 46A 3% (N/A) (N/A) (N/A) 150W TM201-S12 12V 1.2A 16.7A 2% (N/A) (N/A) (N/A) 200W TM201-S15 15V 1.0A 13.4A 2% (N/A) (N/A) (N/A) 200W TM201-S24 24V 0.6A 8.4A 2% (N/A) (N/A) (N/A) 200W TM201-S30 30V 0.5A 6.7A 2% (N/A) (N/A) (N/A) 200W TM201-S48 48V 0.5A 4.2A 2% (N/A) (N/A) (N/A) 200W TM201-D23 +5.1V 3.0A 30A 2% +12V 0A 8A 4% (N/A) (N/A) 200W TM201-D24 +5.1V 3.0A 30A 2% +15V 0A 6A 4% (N/A) (N/A) 200W TM201-D25 +5.1V 3.0A 30A 2% +24V 0A 4A 4% (N/A) (N/A) 200W TM201-D27 +12V 1.0A 8.7A 2% +24V 0A 4A 4% (N/A) (N/A) 200W TM201-T30 +5.1V 3.0A 30A 2% +12V 0A 8A 4% -5V 0A 6A 4% (N/A) 200W TM201-T31 +5.1V 3.0A 30A 2% +12V 0A 8A 4% -12V 0A 4A 4% (N/A) 200W TM201-T32 +5.1V 3.0A 30A 2% +15V 0A 6A 4% -15V 0A 4A 4% (N/A) 200W TM201-T33 +5.1V 3.0A 30A 2% +15V 0A 6A 4% -12V 0A 4A 4% (N/A) 200W TM201-T36 +5.1V 3.0A 30A 2% +12V 0A 8A 4% 24V 0A 4A 4% (N/A) 200W TM201-Q40 +5.1V 3.0A 30A 2% +12V 0A 8A 4% -12V 0A 4A 4% 5V 0A 6A 4% 200W TM201-Q41 +5.1V 3.0A 30A 2% +15V 0A 6A 4% -15V 0A 4A 4% 24V 0A 4A 4% 200W TM201-Q42 +5.1V 3.0A 30A 2% +12V 0A 8A 4% -12V 0A 4A 4% 12V 0A 4A 4% 200W TM201-Q44 +5.1V 3.0A 30A 2% +12V 0A 8A 4% -15V 0A 4A 4% 15V 0A 4A 4% 200W TM201-Q45 +5.1V 3.0A 30A 2% +12V 0A 8A 4% -12V 0A 4A 4% 24V 0A 4A 4% 200W TM201-Q403 +3.3V 3.0A 30A 3% +5.1V 0A 8A 4% -12V 0A 4A 4% 12V 0A 4A 4% 175W NOTES: 1. Add suffix “C” for enclosed format with option fan control, e.g. TM201-Q45C. 2. Peak current is 12A on +12V, 9A on +15V and 6A on +24V. 3. Output #4 is floating. It can be connected externally for positive or negative output. 4. 200 watts for “C” version with a cover-and-fan assembly. 100 watts for U-bracket version without moving air (maximum current of output #1 & #2 derated to 50%), or 200 watts with 25 CFM forced air provided by user. 5. When the remote Sense facility is no t used, +Sense must be connected to +V, and –Sense to return, on P2 connector. 6. All models may be operated at no-load. At no-load, output voltage tolerance increases to 10%. MECHANICAL SPECIFICATIONS Single Output Models MEDICAL GRADE TM201 SERIES NOTES: 1. Dimensions shown in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector P1 is Dinkle DT-35-B01W-03 output connector P2 is Dinkle DT-35-B01W-09 screws are M3, Nickel plated. 4. Connector P3 mates with Molex housing 22-01-1043 and Molex 40445 series crimp terminal. 5. Connectors P4, P5 mates with Molex housing 22-01-1023 and Molex 40445 series crimp terminal. 6. P4 is for DC fan rated 12V/0.2A, Pin1 +V and Pin2 COM. 7. Weight: Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com

MEDICAL GRADE TM201 SERIES Multiple Output Models PIN CHART P2 P3 P5 1 2 3 4 5 6 7 8 9 1 2 3 4 1 2 TM201-S5.1 TM201-S12 TM201-S24 TM201-S48 TM201-S3.3 TM201-S15 TM201-S30 -SENSE RET. RET. RET. RET. OUTPUT OUTPUT OUTPUT #1 +SENSE FAN COM. RET. COM. RET. PFD INHIBIT+ INHIBIT- TM201-D23 TM201-D25 TM201-D24 TM201-D27 OUTPUT OUTPUT COM. RET. COM. RET. COM. RET. OUTPUT RET. COM. RET. PFD INHIBIT+ INHIBIT- TM201-T30 TM201-T32 TM201-T31 TM201-T33 OUTPUT OUTPUT COM. RET. COM. RET. COM. RET. OUTPUT OUTPUT RET. COM. RET. PFD INHIBIT+ INHIBIT- TM201-T36 OUTPUT OUTPUT COM. RET. COM. RET. COM. RET. OUTPUT #2 N.C. OUTPUT RETURN OUTPUT #3 FAN COM. RET. COM. RET. PFD INHIBIT+ INHIBIT- TM201-Q40 TM201-Q41 TM201-Q44 TM201-Q403 TM201-Q42 TM201-Q45 OUTPUT OUTPUT COM. RET. COM. RET. COM. RET. OUTPUT OUTPUT OUTPUT RETURN OUTPUT #4 FAN COM. RET. COM. RET. PFD INHIBIT+ INHIBIT- CONN PIN Product No. NOTES: 1. Dimensions shown in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector P1 is Dinkle DT-35-B01W-03 output connector P2 is Dinkle DT-35-B01W-09 screws are M3, Nickel plated. 4. Connector P3 mates with Molex housing 22-01-1043 and Molex 40445 series crimp terminal. 5. Connectors P4, P5 mates with Molex housing 22-01-1023 and Molex 40445 series crimp terminal. 6. P4 is for DC fan rated 24V/0.2A (models TM201-D25/D27) or 5V/0.38A (models TM201-Q403), and 12V/0.2A (other models, Pin1 +V and Pin2 COM). 7. Weight: Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com