DESCRIPTION

The TM110 series of compact, open PCB constructed, AC-DC switching power supplies are specially designed for medical applications. They are capable of delivering 72 to 110 watts of continuous power at 25 CFM forced air cooling or 80 watts at convection cooling. They operate at 85 to 264VAC input voltage without the need of changing jumper. All models meet the safety requirements of UL, CSA and IEC for medical applications.

FEATURES

‧ Low safety ground leakage current ‧ Meet EN55011 and FCC Class B ‧ Small size, light weight ‧ 100% burn-in ‧ Wide input range 85 to 264VAC ‧ Input surge current protection ‧ Overvoltage protections ‧ Overcurrent protections ‧ Compliant with RoHS requirements TM110 SERIES Safety Standard Approvals : GENERAL SPECIFICATIONS Switching frequency: 20KHz to 250KHz, varies with load and line Efficiency: 70% minimum on single output models with Vo ≥12V, 65% minimum on the others Hold-up time: 12 msec minimum at 110VAC Line regulation: ±0.5% maximum at full load Inrush current: 15 amps @115VAC or 30 amps @ 230VAC at 25ºC cold start Withstand voltage: 4000VAC from input to output 1500VAC from input to ground 500VAC from output to ground MTBF: 400,000 hours minimum at full load at 25ºC ambient, calculated per MIL-HDBK-217F, excluding DC fan. EMC Performance (EN60601-1-2: 2001) EN55011: Class B conducted, Class B radiated FCC: Class B conducted, Class B radiated VCCI: Class B conducted, Class B radiated EN61000-3-2: Harmonic distortion, Class A EN61000-3-3: Line flicker EN61000-4-2: ESD, ±8KV air and ±6KV contact EN61000-4-3: Radiated immunity, 3V/m for 80~2500MHz EN61000-4-4: Fast transient/burst, ±2KV EN61000-4-5: Surge, ±1KV diff, ±2KV com. EN61000-4-6: Conducted immunity, 3Vrms EN61000-4-8: Magnetic field immunity, 3A/m EN61000-4-11: Voltage dips, 30% reduction for 500ms, 60% reduction for 100ms and >95% reduction for 10ms UL 2601-1 CSA C22.2 No. 601.1 TÜV EN60601-1 INPUT SPECIFICATIONS Input voltage : 85 to 264VAC Input frequency : 47 to 63 Hz Input current : 3.20A (rms) for 115VAC 1.80A (rms) for 230VAC Earth leakage current : 90µA max. @ 115VAC, 60Hz 150µA max. @ 230VAC, 50Hz (LVD) ENVIRONMENTAL SPECIFICATIONS Operating temperature: 0ºC to +70ºC Storage temperature: -40ºC to +85ºC Relative humidity : Derating: 5% to 95% non-condensing Derate from 100% at +50ºC linearly to 50% at +70ºC Cooling : 110 watts continuous output power at 25 CFM forced air cooling or 80 watts at convection cooling OUTPUT SPECIFICATIONS Output voltage/current: See rating chart Total output power: 110 watts maximum at 25 CFM forced air cooling or 80 watts maximum at convection cooling Ripple and noise: 1% peak to peak maximum Overvoltage protection: Provided on output #1 only; set at 112-132% of its nominal output voltage Overcurrent protection: All outputs protected to short circuit conditions Temperature coefficient: All outputs ±0.04%/ºC max. Transient response: Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500µs after a 25% step load change PFD signal: TTL logic high for normal operation and TTL logic low upon loss of input power. This signal appears at least 1ms prior to +5V output dropping 5% below its nominal value. This signal also provides a minimum delay of 100ms after +5V is within regulation RoHS TRUMPower 110 WATT MEDICAL POWER SUPPLIES Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com

O u t p u t # 1 O u t p u t # 2 O u t p u t # 3 O u t p u t # 4 O u t p u t TM110-S3.3 3.3V 0A 22A 3% (N/A) (N/A) (N/A) 72W TM110-S5.0 5.0V 0A 22A 3% (N/A) (N/A) (N/A) 110W TM110-S12 12V 0A 9.0A 2% (N /A) (N/A) (N/A) 110W TM110-S15 15V 0A 7.5A 2% (N/A) (N/A) (N/A) 110W TM110-S24 24V 0A 4.5A 2% (N /A) (N/A) (N/A) 110W TM110-S30 30V 0A 3.6A 2% (N/A) (N/A) (N/A) 110W TM110-D23 +5.1V 0A 10A 3% +12V 0A 5A 9.0A 3% (N/A) (N/A) 110W TM110-T31 +5.1V 0A 10A 3% +12V 0A 5A 9.0A 3% -12V 0A 1A 4% (N/A) 110W TM110-T32 +5.1V 0A 10A 3% +15V 0A 4A 7.5A 3% -15V 0A 1A 4% (N/A) 110W TM110-Q40 +5.1V 0A 10A 3% +12V 0A 5A 9.0A 3% -12V 0A 1A 4% -5V 0A 1A 4% 110W TM110-Q41 +5.1V 0A 10A 3% +15V 0A 4A 7.5A 3% -15V 0A 1A 4% +24V 0A 1A 4% 110W TM110-Q42 +5.1V 0A 10A 3% +12V 0A 5A 9.0A 3% -12V 0A 1A 4% +12V 0A 1A 4% 110W TM110-Q45 +5.1V 0A 10A 3% +12V 0A 5A 9.0A 3% -12V 0A 1A 4% +24V 0A 1A 4% 110W TM110-Q45-1 +5.1V 2A 10A 3% +12V 0A 5A 9.0A 3% -12V 0A 1A 4% +24V 1.5A 3A 10% 110W TM110-Q45-2 +5.1V 0A 10A 3% +24V 0A 3A 5.0A 3% -12V 0A 1A 4% +12V 0A 1A 4% 110W TM110-Q46 +5.1V 0A 10A 3% +15V 0A 4A 7.5A 3% -15V 0A 1A 4% -5V 0A 1A 4% 110W NOTES: 1. Peak output current with 10% maximum duty cycle for less than 60 seconds. Total peak power must not exceed 130 watts . 2. 110 watts maximum at 25 CFM forced air cooling or 80 watts ma ximum at convection cooling, exce pt model TM110-S3.3 which is rated maximum 60 watts at convection cooling or 72 watts at 25 CFM forced air cooling. 3. Safety agency approvals are for the above listed models in PC B format. To order models with metallic L-bracket or box, add suffix “B” for L-bracket format, or “C” for enclosed format, e.g. TM110-S24C. 4. The output #1 of model TM110-Q45-1 needs a minimum current of 2A to support the other outputs at their maximum rated loads. MECHANICAL SPECIFICATIONS NOTES: 1. Dimensions shown in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector mates with Molex housing 09-50-3051 and Molex 2878 series crimp terminal. 4. Output connector mates with Molex housing 09-50-3131 and Molex 2878 series crimp terminal. 5. Weight: 640 grams (PCB format) 6. The copper pad of the mounting hole near P1 is for system grounding through a metallic stand-off to system chassis. PIN CHART 1, 2, 3 4, 5 6, 7 8, 9 10 11 12 13 TM110-S3.3 TM110-S12 TM110-S24 TM110-S5.0 TM110-S15 TM110-S30 OUTPUT #1 RETURN RETURN OUTPUT TM110-D23 OUTPUT COMMON RETURN COMMON RETURN OUTPUT TM110-T31 TM110-T32 OUTPUT COMMON RETURN COMMON RETURN OUTPUT #2 P.F.D OUTPUT #3 KEY N.C. TM110-Q40 TM110-Q42 TM110-Q45-1 TM110-Q46 TM110-Q41 TM110-Q45 TM110-Q45-2 OUTPUT COMMON RETURN COMMON RETURN OUTPUT #2 P.F.D OUTPUT #3 KEY OUTPUT PIN Product No. Tumbler Technologies + TRUMPower 3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com OUTPUT VOLTAGE/ CURRENT RATING CHART MEDICAL GRADE TM110 SERIES