www.Amprobe.com www.Amprobe.comAmprobe® Test Tools Data Sheet No hassle warranty No waiting. No shipping charges. Our commitment to high-quality products and customer service is demonstrated by our industry exclusive “No Hassle” warranty. In the unlikely event that an Amprobe Test Tool requires warranty service, any of our local dealers are authorized to replace it, on the spot. HD160C Heavy-Duty Digital Multimeter Rugged autoranging meter with true-rms Key features: Measures 1500 VDC CAT IV 1000 V IP67 Rated Temperature, Frequency & Capacitance Magne-Grip™ holster with magnetic hanging strap Highest voltage capability, measuring to 1500 Vdc and 1000 Vac CAT IV 1000 V rated Special sealing for environment and water resistance. IP67 rated Constructed with drop-resistant housing and PCB mounting Measures capacitance, temperature and frequency Superior 10,000 count resolution with bar graph Magne-Grip™ holster, frees both hands for work Includes high voltage test leads with threaded alligator clips Temperature measurement built-in Frequency and capacitance Digi-Glo™ bright backlight The HD160C is designed for profes- sional use in harsh environments. The meter is unusually rugged and reliable in everyday heavy use ap- plications. The meter is made using waterproof construction to prevent dirt, grime and moisture from enter - ing the case and causing inaccurate readings or damaging shorts. Built of tough, fire-retardant thermoplastic resistant to grease and chemical spills, with all sensi- tive components shock-mounted for a drop resistance to at least eight feet. Model HD160C has an extended voltage measurement capability of
1500 V dc and 1000 V ac, unmatched
by any other line of digital multime- ters. The extended voltage ranges can withstand transients up to 12 kV. HD160C N10140
Amprobe® Test Tools Data SheetHD160C Technical Specifications General Specifications Display 4 digit LCD, 9999 counts, with annunciators, menu features and 41 segment bargraph. Polarity Indication Automatic Input overload indication OL, -OL. Low Battery Indication B; less than 50 hours battery life remain, accuracy is no longer guaranteed Display Update Rate 2/sec, nominal; 20/sec for bargraph. Oper. Temp. 0 °C to +50 °C @ 0 to 75 % R.H. Storage Temp. -20 °C to 60 °C @ 0 to 80 % RH, battery removed Altitude 2000 meters - indoor use Temperature coefficient 0.1 x (spec. accuracy)/°C (0 °C to 18 °C and 28 °C to 50 °C) Fuse F 2 A/1500 V fuse (8 mm x 65 mm), I.R. 30 kA – Amprobe p/n FP700 Power Standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22 Auto Power-Down Meter powers down after approximately 30 minutes of inactivity. Not in Min/Max function. Battery Life (typical) 150 hours, alkaline. Backlight usage consumes extra power and will decrease battery life significantly. Backlight auto-off after approx. 60 seconds. Dimensions, without holster (H x W x D) 200 x 102 x 59 mm (7.9 in x 4.0 in x 2.3 in) Weight (incl. battery) 642 g (22 oz) Accessories Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (installed), hex wrench (inside holster), Holster with Magne-Grip strap, Type K thermocouple probe (TP255), Tempera - ture Adaptor (TA-1A) and User Manual. Case material Reinforced, high-impact, fire retardant thermoplastic Safety Meets EN 61010-1 CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67 EMC Meets EN 61326-1 Electrical Specifications (Accuracy at 23 °C ± 5 °C, <75 % RH, guaranteed for one year.) Function Range Accuracy DC Volts Ranges 1000 mV, 10 V, 100 V, 1500 V Resolution 0.1 mV in 1000 mV range Accuracy ±(0.1 % rdg + 5 dgt) Input Impedance 10 MΩ CMRR >120 dB up to 1500 V dc NMRR >60 dB at 50 or 60 Hz OL Protection 1500 V dc or 1000 V ac rms. Transient protection 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V/1500V dc product. This product should not be used in installations where transients exceed 12 kV. AC Volts True rms Ranges 1000 mV, 10 V, 100 V, 1000 V Resolution 0.1 mV in 1000 mV range Accuracy 1000 mV (45 Hz to 400 Hz) ± (1.2 % rdg + 10 dgt) 10 V, 100 V (45 Hz to 500 Hz) ± (1.2 % rdg + 10 dgt) 10 V, 100 V (500 Hz to 2 kHz) ± (2.0 % rdg + 10 dgt) 1000 V (45 Hz to 1 kHz) ± (2.0 % rdg + 10 dgt) Input Impedance 10 MΩ Conversion type True rms, ac coupled 5 % to 100 % of range Crest factor ≤ 3 OL Protection 1500 V dc or 1000 V ac rms Transient protection 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV
www.Amprobe.com Data SheetHD160C Technical Specifications (continued) Function Range Accuracy DC Current Ranges 100 µA, 1000 µA, 10mA, 100mA, 400mA, 2A (Auto/Manual ranging) Resolution 0.01µA in 100 µA range Accuracy 100 µA range ± (0.5% rdg + 10 dgts) 1000 µA to 400 mA ranges ± (0.5% rdg + 5 dgts) 2 A range ± (1.5% rdg + 10 dgts) Input protection 2 A/1500 V fast blow ceramic fuse 8×65 mm on A input , FP700 Burden voltage voltage µA range of 1 mV/1 µA, mA range of 10 mV/1 mA, 2A range of 500 mV/1A, 500 mV max. (2 V max. on 1000 µA, 100 mA, 400 mA, 2 A ranges) OL Protection A Input (F 2 A/1500 V, size 8 x 65 mm IR fast blow ceramic) AC Current True rms Current True rms Ranges 100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 2 A Resolution 0.01 µA in 100 µA range Accuracy (45 Hz to 1kHz) 100 µA to 100 mA ± (1.5 % + 10 dgts) 400 mA ± (2.0 % + 10 dgts) Voltage burden burden see DC Current DC Current Conversion type True rms ac coupled 10 to 100% of range Crest factor ≤ 3 OL protection see DC Current Resistance Ranges 1000 Ω, 10 kΩ, 100 kΩ, 1000 kΩ, 10 MΩ, 40 MΩ Resolution 0.1 Ω in 1000 Ω range Accuracy 1000 Ω to 1000 kΩ ranges ± (0.5 % rdg + 8 dgts) 10 MΩ range ± (1.0 % rdg + 10 dgts) 40 MΩ range ± (2.0 % rdg + 10 dgts) Overload protection, all ranges 1500 V dc or 1000 V ac rms Continuity Test Audible indication Less than 40 Ω Response time 100 ms Overload protection 1500 V dc or 1000 V ac rms Capacitance Ranges 40 ηF, 400 ηF, 4 µF, 40 µF, 400 µF (3999 counts) (Auto/Manual ranging) Resolution 0.01 ηF Accuracy 40 ηF, 400 µF ranges ±(3.0% rdg +10 dgts) 400 ηF to 40 µF ranges ±(3.0% rdg +5 dgts) Test voltage < 1 V Test Frequency Frequency 1.3 Hz on 40 ηF to 40 µF ranges; 0.7 Hz on 400 µF range Overload protection protection 1500 V dc or 1000 V ac rms dc or 1000 V ac rms or 1000 V ac rms ac rms Temperature Ranges -20 °C ~ 1300 °C (-4° F ~ 2372 °F) 3999 counts Resolution 1 °C, 1 °F Accuracy -20 °C ~ 10 °C ±(2.0% rdg + 4 °C) Overload protection 1500 V dc or 1000 V ac rms (continued on next page)
www.Amprobe.comAmprobe® Test Tools Data Sheet ©2007 Amprobe Test Tools. All rights reserved. 3/2007 PN: 1646298 Rev C HD160C Technical Specifications (continued) Function Range Accuracy Frequency Ranges 100Hz, 1000Hz, 10kHz, 100kHz, 1000kHz, 10MHz Resolution 0.01 Hz on 100 Hz range Accuracy ±(0.1% rdg + 5 dgts) Sensitivity 3 Hz to 1 MHz >2.5 V ac rms 1MHz to 10MHz >2.5 V ac rms, <5 V ac rms Minimum input range 100 Hz range >3 Hz;
1000 Hz range >30 Hz
Minimum pulse width > 25 ns Duty cycle limits > 30 % and < 70 % Overload protection 1500 V dc or 1000 V ac rms Included Accessories Heavy Duty CAT IV 1000 V Test leads with threaded alligator clips (TL1500), battery (installed), hex wrench (inside holster), Holster with Magne-Grip strap, Type K thermocouple probe (TP255), Temperature Adaptor (TA -1A) and User Manual. Optional Accessories TL1500 Cat IV 1000 V Test Leads with Alligator Clips CT235A 1000 A ac/dc Clamp CT237A 200 A ac/dc Current Clamp CT238A 20 A ac/dc Current Clamp VC221B Padded Vinyl Case. Fits meter & holster. DC205C Deluxe Hard-Shell Carry Case DC207C Large Deluxe Hard-Shell Carry Case with extra space for accessories HV231-10A High Voltage Probe FP700 Replacement Fuse, 2 A/1500 V, pack of two TA-1A K-type thermocouple, temperature adapter Amprobe® Test Tools website: www.Amprobe.com email: info@amprobe.com 6920 Seaway Blvd. Everett, WA 98203 tel: 877-AMPROBE Amprobe® Test Tools Europe P.O. Box 1186