beha-amprobe.com ©2024 Beha-Amprobe® 6010444 D-eng Beha-Amprobe® Division of Fluke Corp. (USA) c/o Fluke Europe BV In den Engematten 14
79286 Glottertal, Germany
Tel. +49 (0) 7684 - 8009-0 info@beha-amprobe.de beha-amprobe.de Beha-Amprobe
52 Huricanne Way
info@beha-amprobe.co.uk beha-amprobe.com Science Park Eindhoven
5110 NL-5692 EC Son
Tel. +31 (0) 40 267 51 00 beha-amprobe.com The Beha-Amprobe 2100-Alpha, 2100-Beta and 2100-Gamma are rugged and reliable two pole voltage testers for voltage and continuity checks. Built tough for use in industrial and commercial environments, the 2100 Series is safety rated up to CAT III 1000 V / CAT IV 600 V and measures voltage range up to 1000 V AC and 1200 V DC (2100-Gamma only). Designed with reinforced components for dependable performance, the 2100 Series has an ingress protection degree of IP 64 and is built according to voltage tester standard EN 61243-3:2014 and is GS approved.
2100 Series Two Pole
2100-Alpha | 2100-Beta | 2100-Gamma
2100 Series Features
- Colored LED display to make different voltage levels more visible
- Automatic AC/DC voltage detection with polarity indication
- Voltage test up to 1000 V AC /
1200 V DC (2100-Gamma)
- Switchable load and 10 mA or 30 mA RCD trip test with two push buttons
- Automatic continuity test with visual (LED)
- Low resistance indication to check wiring in contactor and relay application without influence of the coils (2100-Gamma)
- Single pole test to check phase polarity
- Two pole phase rotation indication with indicator for right and left rotation
- Robust, double insulated cable with wear indication shows when the test leads are excessively worn or damaged and need replacement
- Backlight (2100-Beta/2100-Gamma)
- Torch light / measurement area illumination for working in poorly lit areas
- Audible indication when detected voltages above 50 V AC and 120 V DC
- Auto power ON/OFF and ON/OFF button
- Resistance measurement - to 1999 ohms (2100-Gamma)
- Data Hold (2100-Beta/2100-Gamma)
- IP 64 splash and dust proof
- GS approved, built according to IEC 61243-3:2014, EN 61243-3:2014, DIN VDE 0682-401:2015
- Safety rated CAT IV 600 V / CAT III 690 (CAT III 1000 V 2100-Gamma) 2100-Alpha 2100-Beta
600 V690 V
beha-amprobe.com Push buttons for switchable load and RCD trip test LCD screen LED Panel for:
- Phase rotation indication
- continuity test
- Single-pole phase test
- polarity
- voltage indicator Torch light 2100-Gamma 4mm test probe extension (screwable) protective probe caps GS38 Test probe protector cover with accessory probe and cap storage JAHRE YEARS GARANTIE W ARRANTY GARANTIE WARRANTY GARANTIE WARRANTY JAHRE YEARS GARANTIE W ARRANTY GARANTIE WARRANTY GARANTIE WARRANTY JAHRE YEARS GARANTIE W ARRANTY GARANTIE WARRANTY GARANTIE WARRANTY
Beha-Amprobe® Division of Fluke Corp. (USA) c/o Fluke Europe BV In den Engematten 14 Tel. +49 (0) 7684 - 8009-0 info@beha-amprobe.de beha-amprobe.de Beha-Amprobe e-mail: info@beha-amprobe.co.uk beha-amprobe.com Science Park Eindhoven Tel. +31 (0) 40 267 51 00 beha-amprobe.com ©2024 Beha-Amprobe® 6010444 D-eng beha-amprobe.com Quick Guide Features: 2100-Alpha 2100-Beta 2100-Gamma Safety Rating (measurement category) CAT III 690 / CAT IV 600 CAT III 690 / CAT IV 600 CAT III 1000 / CAT IV 600 Voltage Test • • • Voltage Indication - LCD 6 - 690 V AC/DC 6 - 1000 V AC, 6 - 1200 V DC Voltage Indication - LED 12 - 690 V AC/DC 12 - 690 V AC/DC 12 - ≥690 V AC/DC Continuity Test (visual and audible indication) < 500 kΩ < 500 kΩ < 500 kΩ RCD Trip Test (10 mA or 30 mA) • • • Single Pole Phase Test • • • Full Range Polarity Detection • • • Two Pole Phase Rotation Indication Right/Left Right/Left Right/Left IP 64 Splash and Dust Proof • • • Backlight • • Torch Light/Measurement Area Illumination • • • Double Insulated Cable with Wear Indication • • • 4 mm Test Probe Extensions (screwable) and protective probe caps GS38 • • • Data Hold Function • • Resistance Measurement 0...1999 Ω Low Resistance Indication Sound < 10 Ω Test probe protector cover with accessory storage Store the 4 mm test probe extensions and GS38 protective probe caps, ensuring you always have them when needed. The test probe protector cover tip also helps to open UK electrical safety outlets. Two Button Switchable Load/ RCD Trip Test When the two buttons are not pressed the unit is in high impedance mode, providing additional safety protection when testing live power sources, and avoiding accidental tripping of residual-current devices (RCD). When the buttons are pressed the unit is in low impedance mode, eliminating inaccurate readings as result of ghost voltage. Additionally, in systems with RCDs you can press the buttons to intentionally trip 10 mA or 30 mA RCDs and determine if they are wired correctly. Long, durable test leads with wear indicator Extra-long 1.5 m test leads make testing fast and convenient. The two pole tester’s rugged, durable test leads have two layers of insulation for added durability and safety. If the inner, contrasting-colored layer is showing, that’s a sign that the test leads require replacement.
©2024 Beha-Amprobe® 6010444 D-eng
2100 Series Specifications
2100-Alpha 2100-Beta 2100-Gamma Voltage Test LED indicator ±12, ±24, 50, 120, 230, 400, 690 V ±12, 24, 50, 120, 230, 400, ≥690 V LED tolerances acc. to EN 61243-3:2014 LCD resolution – 1 V LCD tolerance – ± (3% rdg + 3 LSD) Frequency range DC, 16 2/3 Hz...1000 Hz LED and LCD response time <1s Acoustic indication ≥50 V AC, ≥120 V DC Voltage detection Automatic (AC/DC) Polarity detection Full range Range detection Automatic Current I (load buttons not activated) ≤3.5 mA AC/DC at 690 V AC/DC ≤3.5 mAAC at 1000 VAC / ≤4.5 mADC at 1200 VDC Internal load (load buttons not activated) Approximately 2.4 W at 690 V AC/DC Approximately 3.5 W at 1000 VAC / Approximately 5.4 W at 1200 VDC Test current switchable load (load buttons activated) ≤250 mA AC/DC at 690 V AC/DC ≤350 mAAC at 1000 VAC / ≤420 mADC at 1200 VDC Switchable load (load buttons activated) Approximately 170 W at 690 V AC/DC Approximately 350 W at 1000 VAC / Approximately 500 W at 1200 VDC Automatic power ON LED: >10 V LED: >10 V LCD: >10 V LED: >10 V LCD: > 10 V Impedance at ELV level 270 kΩ @ 50 VAC 270 kΩ @ 50 VAC 320 kΩ @ 50 VAC Impedance at ELV level and switched load 5 kΩ @ 50 VAC 5 kΩ @ 50 VAC 5 kΩ @ 50 VAC Trip Test of RCD (earth leakage circuit breaker) Test current switchable load (load buttons activated) >30 mAAC at 230 VAC Single Pole Phase Test Voltage range 100…690 VAC against earth 100…1000 VAC against earth Frequency range 40 Hz...70 Hz Acoustic indication yes Indication Red LED Continuity Test (Rx) / Diode Test Range 0...500 kΩ Tolerance 0% to +50% Test current <5 μA Acoustic indication yes Diode test yes Indication Yellow LED Overvoltage protection 690 V AC/DC 1000 VAC/1200 VDC Automatic power ON < 500 kΩ Phase Rotation Indication Voltage range 170...690 V AC phase to phase 170…1000 V AC phase to phase Frequency range 40…70 Hz 40…70 Hz Indication Green LEDs Resistance Measurement ( Ω ) / Low Resistance Indication “ “ (2100-Gamma only) Resistance range on LCD 0...1999 Ω Resolution 1 Ω Tolerance ± (5% rdg + 10 LSD) at 20°C Temperature coefficient ± (5 LSD / 10 K) Test current <30 μA Low resistance indication Acoustic indication <10...50 Ω Overvoltage protection 690 V AC/DC 1000 VAC/1200 VDC Data Hold – only voltage measurement (12...690V AC/DC) voltage and resistance measurement Measurement Area Illumination / Torch Light Torch light White LED Backlight White LED General Specifications Operation time (DT) 30 s Recovery time 240 s Operating temperature -15°C to +55°C Storage temperature -15°C to +55°C Humidity Max. 95% RH Operating altitude Up to 2000 m Safety rating (measurement category) CAT IV / 600V, CAT III / 690V CAT IV / 600V, CAT III / 1000V Pollution degree 2 Protection degree IP 64 Safety regulations IEC 61243-3:2014, EN 61243-3:2014, DIN VDE 0682-401:2015 Approvals, compliance GS mark from TÜV Rheinland, CE Power Supply Battery 2 x 1.5V (AAA/ IEC LR03) Power consumption Approximately 90 mA Battery lifetime More than 10000 measurements (<5 s / per measurement) Dimensions (HxWxD) Approximately 280 x 78 x 35 mm (11.0 x 3.1 x 1.4 in) Weight Approximately 320 g (0.71 lb)