GREYSTONE IS AN ISO 9001 REGISTERED QUALITY SYSTEM STACK TEMPERATURE TRANSMITTER TE500H SERIES PRODUCT DESCRIPTION The TE500H series single point rigid stack temperature transmitter utilizes a precision, high temperature rated platinum RTD sensor that is encapsulated in 6.35 mm (0.25”) OD, 304 series stainless steel probe and is available in various lengths. All probes provide excellent heat transfer, fast response and resistance to moisture penetration. A weatherproof enclosure is provide for wire termination. A transmitter that provides a high accuracy signal with excellent long term stability, low hysteresis and fast response is provided. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. The stack type probes are installed in the side of an exhaust stack to monitor the flue gas temperatures. Select a probe length that allows the probe tip close to the center of the stack. Install the probe through a hole in the side of the stack and mount by securing the flange directly on the side. A weatherproof enclosure is provided for wiring connections. SENSOR 100Ω Platinum RTD or 1000Ω Platinum RTD Wire wound, 3 wire, IEC 751, 385 Alpha SENSOR ACCURACY ±0.3°C (±0.54°F) @ 0°C (32°F) PROBE TEMPERATURE RANGE -100 to 600°C (-148 to 1112°F) WIRE MATERIAL 22 AWG, fiberglass jacket PROBE MATERIAL 304 series stainless steel PROBE DIAMETER 6.35mm (0.25”) OUTPUT SIGNAL 4-20 mA current loop, 0-5 Vdc, or 0-10 Vdc (factory configured) TRANSMITTER ACCURACY ±0.1% of span, including linearity 4-20 mA LOOP POWER SUPPLY 15-35 Vdc or 22-32 Vac MINIMUM CURRENT LOOP 2 mA nominal (occurs with shorted sensor) MAXIMUM LOOP CURRENT 22.5 mA nomincal (occurs with open sensor) MAXIMUM LOOP LOAD >600Ω 0-5 VDC POWER SUPPLY 10-35 Vdc or 10-32 Vac 0-10 VDC POWER SUPPLY 15-35 Vdc or 15-32 Vac MAXIMUM CURRENT (VOLTAGE) 5 mA nominal MAXIMUM OUTPUT (VOLTAGE) Limited to <5.5 Vdc for 0-5 Vdc, <10.5 for 0-10 Vdc INPUT VOLTAGE EFFECT Negligible over specified operating range RFI REJECTION Good RFI rejection of normal frequencies PROTECTION CIRCUITRY Reverse voltae protected and output limited AMBIENT CONDITIONS 0 to 70°C (32 to 158°F), 0-95 %RH non-condensing ENCLOSURE (W) - Cast aluminum, IP64 (NEMA 3X) WIRING CONNECTIONS Screw terminal block (14 to 22 AWG) COUNTRY OF ORIGIN Canada SPECIFICATIONS 114.3mm 4.5” 88.9mm 3.5” Mounting Holes (X2) Ø 0.200” 114.3mm 4.5” 53.9mm 2.125” 114.3mm 4.5” 6.35mm 0.25”

304 Series S/S Probe

2.85” 2X Ø 0.50” NPT

PRINTED IN CANADA Copyright © Greystone Energy Systems Inc. All Rights Reserved www.greystoneenergy.com PS-TE500HXXX-02-02 10/19 Greystone Energy Systems, Inc.

150 English Drive, Moncton,

New Brunswick, Canada E1E 4G7 Ph: +1 (506) 853-3057 Fax: +1 (506) 853-6014 North America: 1-800-561-5611 E-mail: mail@greystoneenergy.com PRODUCT TE500H Stack Temperature Transmitter SENSOR 4 100Ω Platinum, 3 wire, IEC 751, 385 Alpha, wire wound 1000Ω Platinum, 3 wire, IEC 751, 385 Alpha, wire wound PROBE LENGTH A2 50mm (2”) 100mm (4”) 150mm (6’) 200mm (8”) 300mm (12”) 450mm (18”) OUTPUT 1A 4-20 mA 0-5 Vdc 0-10 Vdc TRANSMITTER SCALED RANGE 9H 0 to 600°C 0 to 1000°F Custom ranges available ORDERING TE500H PART NUMBER NOTE: Greystone Energy Systems, Inc. reserves the right to make design modifications without prior notice. CUSTOM SCALED RANGE