SM8050 IFM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
Magnetic-inductive flow meter SMR11GGX10KG/US ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SM8050-02 — 30.06.2016 — Product characteristics Number of inputs and outputs Number of analog outputs: 1 Process connection threaded connection G 1 DN25 flat seal Application System gold-plated contacts Application for industrial applications Installation connection to pipe by means of an adapter Media Conductive liquids; water; water-based media Note on media conductivity: ≥ 20 µS/cm viscosity: < 70 mm²/s (40 °C) Medium temperature [°C] -10...70 Pressure rating [bar] 16 Pressure rating [Mpa] 1.6 MAWP (for applications according to CRN) [bar] 11.2 Electrical data Operating voltage [V] 18...30 DC; (according to EN 50178 SELV/PELV) Current consumption [mA] 95; (24 V) Protection class III Reverse polarity protection yes Power-on delay time [s] 5 Inputs / outputs Number of inputs and outputs Number of analog outputs: 1
Magnetic-inductive flow meter SMR11GGX10KG/US ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SM8050-02 — 30.06.2016 — Outputs Total number of outputs 1 Output signal analog signal; IO-Link; (configurable) Permanent current rating of switching output DC [mA] 250 Number of analog outputs 1 Analog current output [mA] 4...20 Max. load [Ω] 500 Overload protection yes Measuring/setting range Measuring range [l/min] 0.2...100 Accuracy / deviations Flow monitoring Accuracy (in the measuring range) Repeatability ± 0,2% MEW Reaction times Flow monitoring Response time [s] 0.15; (dAP = 0, T19) Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis SIO mode yes Required master port class A Process data analogue 2 Min. process cycle time [ms] 3 Supported DeviceIDs Type of operation DeviceID default 577 Operating conditions Ambient temperature [°C] -10...60 Storage temperature [°C] -25...80 Protection IP 67 Tests / approvals EMC DIN EN 60947-5-9 Shock resistance DIN IEC 68-2-27 20 g (11 ms) Vibration resistance DIN IEC 68-2-6 5 g (10...2000 Hz) MTTF [years] 167 Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Magnetic-inductive flow meter SMR11GGX10KG/US ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SM8050-02 — 30.06.2016 — Mechanical data Weight [g] 591.5 Material stainless steel (1.4404 / 316L); PBT-GF20; FKM; TPE Materials (wetted parts) stainless steel (1.4404 / 316L); PEEK; FKM Process connection threaded connection G 1 DN25 flat seal Remarks Remarks MW = Measured value MEW = Final value of the measuring range Pack quantity 1 pcs. Electrical connection Connector: 1 x M12; Contacts: gold-plated Connection Colours to DIN EN 60947-5-2 OUT1: IO-Link OUT2: analog output Core colors : BN = brown WH = white BK = black BU = blue
Magnetic-inductive flow meter SMR11GGX10KG/US ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — SM8050-02 — 30.06.2016 — Diagrams and graphs Pressure loss dP Pressure loss Q volumetric flow quantity