IGB3008BBPKG/K1/V4A/US-104 ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — IGS287-00 — 04.09.2017 — Product characteristics Electrical design PNP Output function normally open Sensing range [mm] 8 Housing Threaded type Dimensions [mm] M18 x 1 / L = 45 Application System gold-plated contacts; Increased sensing range; correction factor = 1; Magnetic-field immune Application material handling; refrigerated warehouse / shock freezing Magnetic-field immune yes Max. electromagnetic field immunity [mT] 300 Electrical data Operating voltage [V] 10...30 DC Current consumption [mA] < 20 Protection class III Reverse polarity protection yes Outputs Electrical design PNP Output function normally open Max. voltage drop switching output DC [V] 2.5 Permanent current rating of switching output DC [mA] 100 Switching frequency DC [Hz] 2000 Short-circuit protection yes Overload protection yes Monitoring range Sensing range [mm] 8 Real sensing range Sr [mm] 8 ± 10 % Operating distance [mm] 0...6.48 Increased sensing range yes

IGB3008BBPKG/K1/V4A/US-104 ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — IGS287-00 — 04.09.2017 — Accuracy / deviations Correction factor steel: 1 / stainless steel: 1 / brass: 1 / aluminum: 1 / copper: 1 Hysteresis [% of Sr] 3...15 Switch-point drift [% of Sr] -10...10 Correction factor = 1 yes Operating conditions Ambient temperature [°C] -40...85 Protection IP 65; IP 66; IP 67; IP 68; IP 69K Tests / approvals EMC EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V EN 55011 class B Vibration resistance EN 60068-2-6 Fc 20 g (10...3000 Hz) / 50 sweep cycles per frequency; 1 octave per minute in 3 axes Shock resistance EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes Continuous shock resistance EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes Fast temperature changes EN 60068-2-14 Na TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles Salt spray test EN 60068-2-52 Kb severity level 5 (4 test cycles) MTTF [years] 470 UL approval Ta -25...70 °C Enclosure type Type 1 voltage supply Limited Voltage/Current UL approval number A005 File number UL E174191 Mechanical data Weight [g] 38.1 Housing Threaded type Mounting flush mountable Dimensions [mm] M18 x 1 / L = 45 Thread designation M18 x 1 Material stainless steel (1.4404 / 316L); sensing face: LCP white; LED window: PEI; lock nuts: stainless steel (1.4404 / 316L) Displays / operating elements Display Switching status 4 x LED, yellow Accessories Accessories (supplied) lock nuts: 2 Remarks Pack quantity 1 pcs. Electrical connection - plug Connector: 1 x M12; Contacts: gold-plated

IGB3008BBPKG/K1/V4A/US-104 ifm efector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — IGS287-00 — 04.09.2017 — Connection