SLU-600 ATC | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 2
Technical content
AUTO Frequency Nominal Line-to- Adjustable RANGING Line Voltages Range SCALES 60Hz 208, 220, 240 200-250 380, 415, 440, 360-500 460, 480, 575, 600 550-630 50Hz 208, 220, 240 200-250 346, 380, 415 330-430 3Ø VOLTAGE Drop-out ±10% of Range Setting (Under/Over) BAND Pick-up ±7% of Range Setting (Under/Over) CONTROL VOLTAGE 120 VAC ±10%, 50/60Hz MAXIMUM 700 VAC (Line-to-Line) VOLTAGE PHASE ABC (Will Not Operate On CBA Sequence) SEQUENCE POWER REQUIRED 90VA Max. PHASE 2% to 10%, Adjustable Drop-out UNBALANCE Hysteresis 10% of Setting PHASE SHIFT 13° Drop-out, 12° Pick-up (Ø-Loss) FREQUENCY 50/60 Hz SHIFT Drop-out ± 4% Pick up ± 3% RAPID CYCLING 5 Cycle Lockout, 30-Min. Cycle Count Reset RESET Automatic or Manual Mode Clears Rapid Cycle Count RELAY OUTPUT DPDT, 10A @ 240 VAC Resistive LED'S Flashing Continuous Normal Fault Delay Relay (Green LED) Active Energized Fault (Red LED) Restart Delay Relay Active De-energized Over (Red LED) Restart Delay Relay Active De-energized Unbal / Ø Loss Restart Delay Relay (Red LED) Active De-energized RESPONSE Power Up 2.5 S Minimum Fault Delay 0.1 to 25 S, Adjustable Severe Fault 100mS (Ø-Loss, Unbalance or Ø Reversal) Restart 0.5 to 300 S, Adjustable (Auto Reset) TEMPERATURE Operate 32° to 131°F (0° to +55°C) RATINGS Storage -49° to 185°F (-45° to +85°C) REPEAT ACCURACY 1% @ Fixed Condition TERMINALS Plug and Socket Term Block with Spring Pressure Wire Retention, 12 AWG Max. ENCLOSURE 35mm DIN Rail or Surface Mount, Polycarbonate Housing WEIGHT 1.10 lbs. Universal Phase Monitor PHASE VOLTAGE MONITORS SLU-600 Series SPECIFICATIONS IND. CONT . EQ 496Y The ATC-Diversified Electronics SLU-600-ASTDS Universal Phase Moni- tor protects 3-phase motors up to 700VAC. The RAPID CYCLING feature prevents motors cycling due to load-induced line fault conditions. Powered by 120VAC, this reliable motor protection relay is unaffected by transients and disturbances from the monitored power source. The SLU-600 Series is UL Listed under UL File Number E55826.
- Monitors up to 700 VAC
- DIN Rail or Surface Mount
- Operating Range 200-630 VAC
- Manual or Automatic Reset
- Adjustable Restart Delay
- Adjustable Fault Delay PROTECTS AGAINST:
- Rapid Cycling
- Phase Loss
- Phase Reversal
- Phase Unbalance
- Phase Shift
- Over/Under Voltage
- Over/Under Frequency
ORDERING INFORMATION
SLU-600-ASTDS Universal Phase Monitor/Relay
Diversified Electronics 800.727.5646 atcdiversified.com PHASE VOLTAGE MONITORS SLU-600 Series DIMENSIONS (INCHES/MILLIMETERS) TOP LABEL LED STATUS CHART = OFF = ON = FLAS HING Normal Green LED Under Red LED Over Red LED Unbal & Ø Loss Red LED Powering Up/First 3 Sec Powered Up/Normal Voltages Relay ON/Under Voltage Detected/FAULT DELAY active Relay ON/Over Voltage Detected/ FAULT DELAY active Relay ON/Unbal or Ø Loss Detected/FAULT DELAY active Relay OFF/Under Voltage Failure Relay OFF/Over Voltage Failure Relay OFF/Unbal or Ø Loss Failure Relay OFF/Under Voltage Corrected/RESTART DELAY active Relay OFF/Over Voltage Corrected/RESTART DELAY active Relay OFF/Unbal or Ø Loss Corrected/RESTART DELAY active Diversified Electronics 800.727.5646 atcdiversified.com